Skip to main content
OpenTrials
Completed

NCT Number: NCT04718207

Modelling in the Quantitative Analysis of Brain PET Scans in Patients With Alzheimer's Disease

PET/CT scans with 18F-FDG can be carried out for the detection of neurodegenerative diseases with hypometabolisms characteristic of the pathologies sought. The diagnosis is given by the clinician after a visual analysis of the data. To complete the diagnosis, a semi-quantitative analysis of the images is recommended (European recommendations) in addition to the visual analysis.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Nuclear medicine department CHRU de NANCY Brabois

Vandœuvre-lès-Nancy, 54511, France

About this study

PET/CT scans with 18F-FDG can be carried out for the detection of neurodegenerative diseases with hypometabolisms characteristic of the pathologies sought. The diagnosis is given by the clinician after a visual analysis of the data. To complete the diagnosis, a semi-quantitative analysis of the images is recommended (European recommendations) in addition to the visual analysis.

PET technology is improving from year to year thanks to the arrival of a new PET technology called digital. In addition, correction methods have been developed to improve PET images and thus improve the detection of different pathologies in PET.

The PSF (Point Spread Function) tool enables partial volume effects to be corrected. The PSF consists of correcting the impulse response of the system, and allows a visual improvement of the images. Currently not recommended in brain PET/CT reconstructions, it remains to be evaluated for the quantitative analysis of acquisitions.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Brain PET/CT scans at 18F-FDG of patients with Alzheimer's disease carried out in the nuclear medicine department of the Nancy-Brabois University Hospital since December 2017 on digital PET devices.

Exclusion criteria

  • Patients who have expressed their opposition to the use of their data (poster in the service).

Treatment and study plan

Brain positron emission tomopgraphy (PET) - scan

Device

Patients who performed brain PET/CT scans in the nuclear medicine department from December 2017 to December 2020.

Primary outcomes

  1. The results obtained in quantitative analysis with and without PSF modelling of PET brain scans of patients with Alzheimer's disease acquired on PET / CT scan

    Time frame: 6 months

    Comparison of the volumes detected by the quantitative analysis with the SPM (statistical parametric Mapping) software of brain PET scans of patients with Alzheimer's disease with and without FSP modelling.

Sponsors and collaborators

Lead sponsor

Central Hospital, Nancy, France

Other

Registry information

Official study title

Interest of PFS Modelling in the Quantitative Analysis of Brain PET Scans in Patients With Alzheimer's Disease Acquired on a Numerical System

Acronym: PET-SF

Important dates

Study start
2021
Primary completion
2021
Study completion
2022
First posted
Jan 22, 2021
Registry last updated
Aug 24, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.