Minimally Invasive Nasal Trabeculostomy System is intended for the reduction of elevated Intraocular Pressure (IOP).
The system is a powered surgical device, designed to create trabeculostomy openings of ~100 microns diameter each, via an ab-interno approach, directly from the anterior chamber (AC) into Schlemm's canal (SC) by removing segments of the trabecular meshwork (TM) (i.e., an ab-interno nasal trabeculostomy). The ab-interno approach aims to decrease IOP by increasing aqueous outflow through a direct communication from the AC to the outer wall of SC and the collector channels.
The opening in the nasal TM to the SC is created by a sterile surgical instrument (the Surgical Device) made of stainless steel and plastic, which is coupled to a rotating system (the Activation Device). The Surgical Device of the Minimally Invasive Nasal Trabeculostomy System consists of a stainless steel micro trephine, covered by a small needle-shaped sleeve with a rotating mechanism behind it. While being rotated, the Surgical Device enters and moves along the TM, removing TM tissue with minimal collateral damage.
Mechanical rotation of the Surgical Device is achieved by the rotating system (i.e., Activation Device), which is comprised of: (1) Controller which dictates the activation pulse duration, the rotations per minute (RPM) and the forwards and backwards movement of the micro trephine; (2) Motor; and (3) Footswitch.
Looking for future studies?
Notify Me18 year–85 year
All sexes
Interventional
Not applicable
Yerevan, 0048, Armenia
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Mechanical rotation of the Surgical Device is achieved by the rotating system (i.e., Activation Device), which is comprised of: (1) Controller which dictates the activation pulse duration, the rotations per minute (RPM) and the forwards and backwards movement of the micro trephine; (2) Motor; and (3) Footswitch.
Time frame: 24 months
Sanoculis Ltd
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.