mini_FC
Diagnostic Test100 ml of Crystalloids infused over 1 minute - data recording and new baseline - FC 4 ml/kg in 10 minutes - data recording
NCT Number: NCT04934943
The mini fluid challenge (mini_FC) is a functional hemodynamic test which has been used in different clinical contexts to assess fluid responsiveness.
This test is performed by rapidly injecting a small aliquot of fluid (100 ml over 1 minute), which is followed by the infusion of the residual aliquot of fluid.
Since the threshold of the mini_FC identified by the literature is rather small (5% of stroke volume (SV) increase after the 100 ml bolus to discriminate between responder and non-responder), it is crucial that the hemodynamic tool assessing this change could be reliable. Moreover, the SV changes with inspiratory/expiratory movements and the increase after the mini_FC should also consider the physiological fluctuations of the SV.
In the literature this test has been performed by means of tolls with different least significant change of the SV. The least significant change (LSC) represents the smallest difference between successive measurements of SV that can be considered to be a real change and not attributable to chance.
The purpose of this study is to assess the agreement among MOSTCARE system (4.5& of SV LSC described in the literature) and the echocardiography (about 10% of SV LSC described in the literature) with the PICCO system (about 1% of SV LSC described in the literature - considered the gold standard) in discriminating fluid responsiveness after a mini_FC
Trial opening soon.
Get Notified18 year and older
All sexes
Observational
Humanitas Research Hospital, Rozzano, MILANO, Italy
Targeted fluid therapy has received increasing attention in the management of patients showing acute circulatory failure in both intensive care unit (ICU) and operating room (OR), aiming at preventing both inadequate tissue blood flow and fluid overload. In fact, unnecessary fluid administration can increase morbidity and mortality and length of hospital stay of critically ill and surgical patients.
Since the only physiological reason to give a fluid challenge (FC) is to increase the stroke volume (SV) and this effect is obtained only in about 50% of ICU and OR patients, a vast literature investigated the possibility of predict this effect before FC administration, but the issue remains extremely challenging. Bedside clinical signs and pressure and static volumetric static variables, do not predict fluid responsiveness. Moreover, several physiological factors affect the reliability of the ventilator-induced dynamic changes in pulse pressure and stroke volume [pulse pressure variation (PPV) and stroke volume (SV) variation (SVV), respectively], and their echographic surrogates, in a significant number of ICU and OR patients.
To overcome these limitations, the functional hemodynamic assessment (i.e. the assessment of the dynamic interactions of hemodynamic variables in response to a defined perturbation), of fluid responsiveness has gained in popularity. A functional hemodynamic test (FHT) consist in a manoeuvre determining a sudden change in cardiac function and/or heart lung interaction, affecting the hemodynamics of fluid responders and non-responders to a different extent.
The FHT called passive leg raising (PLR) has been successfully used for assessing the fluid responsiveness in ICU patients since 2009 and its reliability has been confirmed by three large meta-analyses. However, the PLR is not usually practicable in the OR.
A lot of different FHTs have been proposed, as alternative to the PLR, in ICU and, more recently, OR. These tests could be basically subdivided in two groups. A subgroup of FHTs is based on sudden and brief variations of the mechanical ventilation to induce a change in right ventricle preload and/or after load and, as consequence, of left ventricle. Among these tests, the rapid administration of a small aliquot of the predefined FC (the so-called mini FC) has gained in popularity in the last years.
On of the drawbacks of this test is that the optimal threshold identified in the literature to stratify responders and non-responders (5% of SV variation) is quite small, and potentially affected by the reliability of the hemodynamic tool used. The aim of this paper is to compare the reliability of a hemodynamic invasive tool (the (PiCCO2 TM, Pulsion Medical Systems, Munich, Germany - considered the gold standard) with a mini-invasive tool (MostCareTM system (Vytech Health, Padua, Italy) and a non-invasive (echocardiography) in predicting the response to the mini-FC in critically ill patients.
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
100 ml of Crystalloids infused over 1 minute - data recording and new baseline - FC 4 ml/kg in 10 minutes - data recording
Time frame: immediately after the procedure
Number of responders and non-responders identified by the MOSTCARE and the Echocardiography with respect to the PICCO system (considered as gold standard)
Time frame: 5 minutes before FC administration
off-line analysis of the recorded stroke volume change before the test
Time frame: 5 minutes before FC administration
off-line analysis of the recorded stroke volume change before the test
Time frame: 5 minutes before FC administration
off-line analysis of the recorded stroke volume change before the test
Time frame: 1 minute after mini fluid challenge infusion
ROC curve analysis of stroke volume changes after mini fluid challenge infusion
Time frame: 1 minute after mini fluid challenge infusion
ROC curve analysis of stroke volume changes after mini fluid challenge infusion
Time frame: 1 minute after mini fluid challenge infusion
ROC curve analysis of stroke volume changes after mini fluid challenge infusion
Time frame: immediately after the procedure
Agreements between stroke volume data are determined using the Bland-Altman method, with the bias calculated as the mean difference between methods and reflecting the measurement error between the two tests.
Time frame: immediately after the procedure
Agreements between stroke volume data are determined using the Bland-Altman method, with the bias calculated as the mean difference between methods and reflecting the measurement error between the two tests.
Humanitas Clinical and Research Center
Other
Acronym: MINI3
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03333278
Cardiovascular Diseases, Critical Illness
Clayton, Victoria, Australia
View Trial DetailsNCT05591924
ARDS, Cognition Disorders
London, Ontario, Canada
View Trial DetailsNCT03395951
Cardiovascular Diseases, Critical Illness
Eindhoven, North Brabant, Netherlands
View Trial DetailsNCT07657702
Arrhythmias, Cardiac, Blood Coagulation Disorders
Wuhu, Anhui, China
View Trial Details