Medical Univeristy of Gdańsk
Gdansk, Dębinki Street, 80-211, Poland
NCT Number: NCT06566495
The purpose of this study was to compare microbial contamination on the surface of reusable stasis after indefinite use, 2 weeks and 4 weeks. We investigated how the site - the operating theater and the emergency department, as well as the time of use - affects the number of organisms.
This study is active but is not currently recruiting participants.
All sexes
Observational
Gdansk, Dębinki Street, 80-211, Poland
The cross-sectional study was conducted in the operating theater and emergency department of a tertiary referral hospital in Gdansk, Poland, in three part from March to April 2024. The study included reusable tourniquets used by the hospital's medical staff during vascular access generation.
After each stage of the in-hospital study, the stasis was collected and replaced with new ones. A total of 53 reusable stasis were collected in three phases of the study and were subjected to microbiological analysis at the Department of Immunobiology and Environmental Microbiology of the Medical University of Gdansk. The tourniquets were collected into disposable, sterile bags. In the first stage of the study, tourniquets were collected of indefinite use (n= 17). In the second and third stages of the study, stasis used for 14 (n=20) and 28 (n=16) days, respectively, were collected. All tourniquets were labeled and assigned to different rooms located within the surveyed wards. The trial was conducted separately, for the plastic fastener and the fabric band. The plastic parts of the tourniquets were placed in sterile glass dishes. Under laboratory conditions, the plastic parts of the stasis were cut off and placed in the dishes. Using sterile swabs soaked in 0.9% sodium chloride, the plastic was swabbed, after which the tip of the swab was cut off, placed in a tube with 0.9% sodium chloride (3ml), which was shaken in a Vortex device (30 seconds) and the obtained material was seeded on columbia Agar with 5% sheep blood. The material part of the stasis was placed in a sterile homogenization bag with the addition of 100ml of nutrient broth. The bag was then placed in a Stomacher Homogenizer for two minutes to detach the microorganisms from the porous surface of the material. The resulting homogenate was transferred in a concentrated state and diluted tenfold using 200 μl pipettes onto columbia Agar media supplemented with 5% sheep blood.200 μl of concentrated homogenate was seeded onto the quality growth media MacConkey Broth, King B Agar, CHROMagar E. coli and other coliforms. The protected material was incubated for 24 hours at 37°C, in an aerobic atmosphere. After this time, bacterial colonies were counted and counts were performed to determine the number of microorganisms on the surface of the stasis (CFU/cm2). Due to the assumptions of the experiment and the time frame, eight tourniquets were not included in the analysis. From the information obtained from the medical staff, this was due to significant soiling, making it impossible to use the tourniquets, and in a few cases the plastic fastener broke.
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Microbiological analysis
The material was collected in each group in the same way.
Other names: sampling of microbiological material
Time frame: 24 hours
After 24h incubation at 37 deg C, we evaluated the number of bacterial colony-forming colonies on leaf and quality plates. The average number of CFU/cm2 in all stages of the study for the emergency department is 19,110, 34 CFU/cm2. For the MCC substrate for the emergency department medium 227.65; standard deviation 102.75 CFU/cm2. For the King B substrate for the emergency department medium 241.71, standard deviation 115.15 18 CFU/cm2. There is no statistically significant difference for OD versus CFU/cm2 during the second and third intake. There were no bacterial growth was obtained on the ECC plate.
Time frame: 24 hours
After 24h incubation at 37 deg C, we evaluated the number of bacterial colony-forming colonies on leaf and quality plates. The average number of CFU/cm2 in all stages of the study for the operating theatre was 88.27 CFU/cm2. For the MCC substrate for the operating theatre medium 14.18 standard deviation 24.06 CFU/cm2. For the King B substrate for the operating theatre medium 33.07 standard deviation 65.18 CFU/cm2.There is no statistically significant difference for OD versus CFU/cm2 during the second and third intake. There were no bacterial growth was obtained on the ECC plate.
Time frame: 2 months
23 of 53 examined tourniquets (43%), 12/18 (67%) from the emergency department and 11/35 (31%) from the operating theatre had visible blood stains. Blood stains did not affect the number of colony-forming units (CFUs).
Medical University of Gdansk
Other
Reusable Tourniquets as Potential Risk of Microbial Transmission - Comparison of Operating Theatre and Emergency Department
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06018792
Antibiotic Side Effect, Bacterial Infections
Amsterdam, Netherlands
View Trial DetailsNCT05575050
COVID-19 Respiratory Infection, Communicable Diseases
Krakow, Poland
View Trial DetailsNCT04325308
Behavior, Breast Feeding
Birmingham, Alabama, United States
View Trial DetailsNCT05167318
Communicable Diseases, Cross Infection
Gainesville, Florida, United States
View Trial Details