The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat.
The main questions it aims to answer are:
Does using a continuous pressure controller reduce fluid leakage past the breathing tube cuff compared to the standard manual method? Does the continuous pressure controller lead to fewer and less severe sore throats and voice changes after surgery?
Researchers will compare two groups:
Group 1: Patients whose breathing tube cuff pressure is managed with a continuous automatic controller.
Group 2: Patients whose breathing tube cuff pressure is managed with the standard manual method.
Participants will:
Be randomly assigned to one of the two groups before their surgery. Receive a small, safe amount of blue dye in their mouth during the procedure to help measure leakage.
Have two small secretion samples collected from their breathing tube during surgery.
Be asked about sore throat and voice changes at 1, 2, 3, and 24 hours after the breathing tube is removed.
Trial opening soon.
Get Notified18 year and older
All sexes
Interventional
Not applicable
CABA, Buenos Aires, 1280, Argentina
Endotracheal intubation is a life-saving procedure, but it inherently bypasses the body's natural defenses against lung infection. A critical, yet often overlooked, problem is microaspiration. This is the silent leakage of small amounts of oropharyngeal secretions past the cuff of the breathing tube and into the lower airways and lungs. This phenomenon is a primary contributor to the development of Ventilator-Associated Pneumonia (VAP), a serious complication that increases patient morbidity, mortality, and healthcare costs.
The cuff's primary role is to create a seal within the trachea. However, conventional cylindrical cuffs can form folds or channels when inflated, creating a direct pathway for secretions to leak through. Furthermore, maintaining the correct cuff pressure (recommended 25-30 cmH₂O) is challenging; pressure can fluctuate due to patient movement, changes in anesthesia gas volume, and surgical positioning.
To address these issues, manufacturers have developed advanced endotracheal tubes. This study focuses on the TaperGuard™ Evac tube (Covidien/Medtronic), which features a uniquely shaped tapered cuff. This design is intended to inflate more uniformly against the tracheal wall, theoretically reducing the formation of leakage channels compared to traditional cylindrical cuffs.
Concurrently, technology for pressure management has evolved. While the current standard of care involves intermittent manual checks with a manometer, automated cuff pressure controllers (like the Pressure Easy® device) have been introduced. These devices continuously monitor and adjust the pressure, maintaining it within a pre-set target range throughout the entire procedure without manual intervention.
While laboratory (bench-top) studies strongly suggest that tapered cuffs are superior at preventing fluid leakage, and some early clinical studies are promising, there is a lack of robust, in-vivo evidence from a controlled surgical setting. This study aims to fill that gap by directly testing the combined effect of the advanced tube design with two different levels of pressure management sophistication.
This trial is not just testing a new device, but rather investigating a clinical management strategy. The central question is: Does moving from a manual, intermittent pressure management protocol to a continuous, automated one provide a significant clinical benefit when using a modern, tapered-cuff endotracheal tube?
To answer this, we are employing a rigorous model to objectively quantify microaspiration:
The Blue Dye Model: A small, safe volume of blue dye is instilled into the patient's oropharynx above the cuff after intubation. The presence or absence of this dye in tracheal aspirate samples, collected later from below the cuff, serves as an objective, binary measure (Yes/No) of whether leakage has occurred.
Beyond the primary goal of preventing pneumonia, the study also investigates patient comfort and safety post-operatively. Damage to the tracheal mucosa from improper cuff pressure or physical irritation from the tube can lead to:
Post-extubation sore throat: A common and uncomfortable complaint.
Post-extubation dysphonia: Hoarseness or voice changes resulting from vocal cord irritation.
By ensuring more stable and optimal cuff pressure, the continuous controller may mitigate these issues. We will track these outcomes using standardized, validated scales (a Numeric Rating Scale for pain and the GRBAS scale for voice quality) to determine if the intervention leads to a tangible improvement in the patient's immediate recovery experience.
To ensure the results are reliable and unbiased, the study employs key methodological safeguards:
Randomization: Patients are randomly assigned to a study group using a computer-generated sequence to ensure groups are comparable.
Partial Blinding: While the clinical team at the bedside cannot be blinded to the monitoring device, the laboratory analysis of the tracheal secretion samples is performed by personnel who are completely unaware of which group the sample came from. This prevents bias in determining the primary outcome.
In summary, this study seeks to provide high-quality evidence to guide clinical practice in operating rooms, determining if an investment in automated pressure control technology yields measurable benefits in patient safety and comfort when using state-of-the-art endotracheal tubes.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Elimination Criteria:
After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP >65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.
Time frame: From enrollment to the end of Surgery: Tracheal aspirate samples will be collected at two defined time points: the first between 10 and 30 minutes after intubation and hemodynamic stabilization, and the second immediately prior to extubation.
Evaluate the penetration of blue-dyed oropharyngeal secretions into the distal airway in patients undergoing orotracheal intubation.
Time frame: Intraoperative ( surgical procedure)
Cuff pressure monitoring will be performed at predefined intervals. In the experimental group, continuous cuff pressure monitoring will be conducted using the Pressure Easy® Cuff Pressure Controller. In the control group, cuff pressure will be manually regulated with a manovacuometer, using the syringe-backflow method to adjust pressure.
Time frame: The pain will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Post extubation pain evaluated using the verbal numerical rating scale (0-10).
Time frame: These dysphonia will be assessed at the following post-extubation time points: 1 hour, 2 hours, 3 hours, and 24 hours.
Post-extubation dysphonia: Assessed using the GRBAS (Grade, Roughness, Breathiness, Asthenia, Strain) clinical scale, with the grade aspect scored from 0 to 3.
Contact information is provided by the study sponsor or research team.
Argentinian Intensive Care Society
Other
Automated Versus Manual Cuff Pressure Control for Preventing Microaspiration With TaperGuard Endotracheal Tubes in Elective Surgery: A Randomized Controlled Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06505850
Breast Cancer, Breast Diseases
Taipei, Taiwan
View Trial DetailsNCT07485972
Endotracheal Tube Cuff Pressure, Postoperative Airway Complications
Adana, Turkey (Türkiye)
View Trial DetailsNCT03646045
Deglutition Disorders, Digestive System Diseases
Wilmington, Delaware, United States
View Trial DetailsNCT05013658
Endotracheal Tube Cuff Pressure
Kocaeli, Kocaeli̇, Turkey (Türkiye)
View Trial Details