Total Hip Replacement
DeviceTotal hip replacement
Other names: Biolox Delta head; Ultamet insert; Pinnacle Acetabular shell
NCT Number: NCT00208494
The purpose of this study is to compare the performance of artificial hips with metal heads and metal sockets to artificial hips with ceramic heads articulating with metal socket components. The success of the total hip arthroplasty (THA) will be based upon all of the following clinical and radiographic criteria being met at the two-year evaluation: (1) the patient's clinical results as measured using modified Harris Hip evaluation rating system, and the absence of a complication that requires the surgical removal or replacement of a component; and (2) radiographic findings at study endpoint (i.e., two years follow-up). Clinical and radiographic success at two (2) years postoperative is required for the study hip to be deemed successful.
Looking for future studies?
Notify Me20 year–75 year
All sexes
Interventional
Not applicable
London, Ontario, Canada
This study is a prospective, multi-center, randomized, single blind, controlled clinical investigation comparing the safety and efficacy of the cementless Ceramic on Metal total hip prostheses versus the cementless Metal on Metal total hip prostheses.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Total hip replacement
Other names: Biolox Delta head; Ultamet insert; Pinnacle Acetabular shell
Time frame: At 24 months
The composite success/failure of the implant was made up of radiographic, clinical and revision data. Radiographic success was determined by femoral subsidence =/< 2mm, acetabular migration =/< 2mm, cup inclination =/< 4°, no acetabular or femoral osteolysis, and acetabular and femoral lucencies less than 50% of visible porous coating. Clinical success was determined by a Harris Hip score equal to or greater than 80. A hip (patient) was considered to be a composite success at study endpoint if it was a radiographic and clinical success and no revision of any component had taken place.
DePuy Orthopaedics
Industry
Comparative Study to Evaluate the Safety and Efficacy of the DePuy Ceramic-on-metal Total Hip Prosthesis Versus the DePuy Metal-on-metal Total Hip Prosthesis Through Clinical and Radiographical Data
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.