Skip to main content
OpenTrials
Completed

NCT Number: NCT03346044

Medtronic's MOSAIC Bioprosthesis Versus Baxter Carpentier-Edwards SAV Porcine Valve

The study compares the clinical performance of the Mosaic valve with that of the Baxter valve (Carpentier-Edwards) which is widely used throughout the UK and is considered to be the "bench mark".

Specific objectives will be to determine structural failure and valve explantation rates, thromboembolic events and mortality rates for each valve.

Haemodynamic assessments will also be made using echocardiography to measure gradients across the valves and changes in left ventricular function and wall thickness.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Plymouth Hospitals NHS Trust

Plymouth, Devon, PL6 8BX, United Kingdom

About this study

The bioprostheses (xenografts) to be used in this study are third generation valves derived from porcine aortic valves. The chief advantage over mechanical prostheses is that they do not require lifelong anticoagulation with warfarin with its attendant risks of haemorrhage if the patient becomes over anticoagulated, or thromboembolism if anticoagulation is inadequate. However their disadvantage is that they are prone to calcification and mechanical failure over time. Because of this, bioprosthetic valves are usually reserved for older patients in whom the chance of repeat surgery is reduced.

The Medtronic Mosaic stented bioprosthesis has been recently introduced. The Mosaic bioprosthesis utilizes Physiological Fixation (root fixation with zero pressure differential across the valve leaflets). This allows valves to maintain their natural leaflet structure and root geometry. The Mosaic bioprosthesis uses the AOA anti-mineralisation treatment. Developed in collaboration with Biomedical Design, Inc., AOA has been shown in multiple animal studies to be an effective treatment in preventing leaflet calcification.

Baxter currently produces the Carpentier Edwards SAV porcine bioprosthesis that has abundant long-term follow-up data and is widely used. Low pressure fixation (less than 1.5mmHg) and anti-mineralisation treatment with FET 80TM are used in its preparation. The stent (which supports the cusps) has been designed to allow for the wider opening angle of the softer leaflets.

These features aim to improve on the haemodynamic performance of earlier generation valves and offer the potential for increased durability. Early results look promising with excellent haemodynamic parameters and remarkably low rates of structural failure.

If zero pressure fixation and anti-mineralisation treatment can be shown to increase the longevity of the bioprosthetic valve, the age criteria for implantation will undoubtedly be lowered allowing a younger cohort of patients to benefit from anticoagulation-free therapy and freedom from associated morbidities.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients who require isolated or combined aortic or mitral valve replacement with or without coronary artery bypass grafting
  • Patients requesting anticoagulation-free therapy
  • Patients who are able to provide informed consent

Exclusion criteria

  • Concomitant procedures other than coronary artery bypass grafting
  • Presence of illness other than valve disease that would substantially increase the likelihood of death within one year
  • Patients unlikely to be available for long term follow-up activities
  • Patients indicated for receiving a mechanical prosthesis
  • Patients refusing or not able to provide informed consent

Treatment and study plan

Carpentier-Edwards SAV bioprostheses

Device

Performance of these bioprostheses

Medtronic Mosaic bioprostheses

Device

Primary outcomes

  1. Mortality

    Time frame: 10 years

    Early mortality was defined as death occurring within 30 days of implantation if the patient was discharged from hospital or at any time after implantation if the patient was not discharged from hospital. Hospital-to-hospital transfer was not considered as discharge. Late mortality was defined as all deaths that occurred after 30 days of implant, if the patient was discharged from hospital.

    The reporting of mortality and morbidity follows the guidelines of the Society of Thoracic Surgeons (STS), the American Association of Thoracic Surgeons (AATS) and the European Association for Cardiothoracic Surgery (EACTS). () Edmunds LH, Clark R, Cohn L, et al. Guidelines for Reporting Morbidity and MortalityAfter Cardiac Valvular Operations. Ann Thorac Surg 1996;62:932-5)

  2. Freedom from structural valve deterioration (SVD)

    Time frame: 10 years

    Defined as re-operation and thromboembolic events. Valve-related complications were defined as thromboembolism, structural valve dysfunction, non-structural valve dysfunction and prosthetic valve endocarditis.

Secondary outcomes

  1. Haemodynamic performance (mmHg)

    Time frame: 10 years

    Transvalvular gradients measured in mmHg

  2. Left ventricular (LV) mass regression (grams)

    Time frame: 10 years

    Evidence of left ventricular mass regression measured in grams

Sponsors and collaborators

Lead sponsor

University Hospital Plymouth NHS Trust

Other

Registry information

Official study title

Medtronic's MOSAIC Bioprosthesis Versus Baxter Carpentier-Edwards SAV Porcine Valve: A Longterm Prospective Randomized Clinical Evaluation

Important dates

Study start
2001
Primary completion
2006
Study completion
2016
First posted
Nov 17, 2017
Registry last updated
Nov 17, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.