Dr. Abdurrahman Yurtaslan Ankara Oncology Hospital
Yenimahalle, Ankara, 06370, Turkey (Türkiye)
Location status: Recruiting
NCT Number: NCT07670494
This study investigates how different breathing machine (ventilator) settings affect the energy delivered to the lungs during surgery. Mechanical power is a measure of this energy, and high levels can sometimes lead to lung irritation. In clinical practice, a mode called Pressure-Regulated Volume Control (PRVC) is often used because it lowers the "peak" pressure in the airways, which is generally thought to be safer. However, doctors have noticed that even though the peak pressure goes down in PRVC mode, the total mechanical power displayed on the monitor might actually increase compared to the standard Volume-Controlled Ventilation (VCV) mode. In this study, patients undergoing gallbladder surgery will be monitored using both ventilation modes in a random order. The researchers will compare the machine-calculated mechanical power for both modes to see if the perceived benefit of lower peak pressure in PRVC actually results in lower overall energy transfer to the lungs.
Interested in participating?
Request Info18 year and older
All sexes
Interventional
Not applicable
Yenimahalle, Ankara, 06370, Turkey (Türkiye)
Location status: Recruiting
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Participants will be ventilated with the traditional Volume-Controlled Ventilation (VCV) mode. Tidal volume, respiratory rate, PEEP, and I:E ratio will be set according to the study protocol and kept constant during the measurement period.
Participants will be ventilated with the Pressure-Regulated Volume Control (PRVC) mode. This is a hybrid mode that uses a decelerating flow to deliver the target tidal volume at the lowest possible pressure. Settings will be identical to the VCV mode for each patient.
Time frame: At the end of a 10-minute stabilization period in each ventilation mode (VCV and PRVC).
The mechanical power value (expressed in Joules per minute - J/min) is automatically calculated and displayed on the monitor of the Mindray A9 anesthesia machine. This value represents the total energy delivered by the ventilator to the patient's respiratory system per minute. The study aims to compare how this machine-calculated value differs between the Volume-Controlled Ventilation (VCV) and Pressure-Regulated Volume Control (PRVC) modes under identical clinical conditions.
Contact information is provided by the study sponsor or research team.
Dr Abdurrahman Yurtaslan Ankara Oncology Training and Research Hospital
Other
Comparison of Mechanical Power in Pressure-Regulated Volume Control and Volume-Controlled Ventilation Modes During Laparoscopic Cholecystectomy
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07647770
Laparoscopic Cholecystectomy, Mechanical Ventilation
Khobar, Eastern Province, Saudi Arabia
View Trial DetailsNCT07607262
Laparoscopic Cholecystectomy, Neurologic Manifestations
Sancaktepe, Istanbul, Turkey (Türkiye)
View Trial DetailsNCT07693621
Dexmedetomidine, Laparoscopic Cholecystectomy
Alexandria, Egypt
View Trial DetailsNCT06982209
General Anesthesia, Laparoscopic Cholecystectomy
Iksan, Jeollabuk-do, South Korea
View Trial Details