University of Copenhagen, Glostrup Hospital
Copenhagen, Glostrup, 2600, Denmark
NCT Number: NCT01971996
During general anaesthesia, to ensure sufficient oxygen supply to the brain, the NIRS technology can be used. It consist of two sensors placed on the forehead, and measures the oxygen saturation of the tissue underneath the sensor. For patients undergoing back surgery placed in the prone position, the NIRS measurement will be affected, because the weight of the head will produce a pressure on the sensors. We wish to investigate how much the measurement is affected. Furthermore we plan to lift the head to remove the pressure, and record the time needed for the measurements to return to baseline.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Copenhagen, Glostrup, 2600, Denmark
When placed in the prone position an external pressure is applied to the NIRS sensor. This pressure changes the amount of blood in the underlying tissue and thereby has an influence on the regional cerebral oxygen saturation measured. We wish to investigate to which extend this value is affected by the external pressure. Furthermore by lifting the head we want to investigate how long takes for the measurements to return to baseline (no pressure in the supine position).
Patients will receive written and oral information about the study, when seen by an anaesthesiologist prior to surgery. Before the anaesthesia one NIRS sensors is placed on the right side of the forehead, avoiding til frontal sinus, and one NIRA sensor is placed on the left musculus deltoideus. The patient is placed in the prone position with the head in af prone-view face mask. Measurements will start after 30 minutes with no change in infusion rate of anaesthetic and no inotropics administered. Registration of NIRS measurements will be done every 15 seconds, first five minutes without intervention, then five minutes with headlift, and last five minutes without interventions. Blood pressure, pulse, saturation, end-tidal carbon dioxide and temperature, will be recorded. Registration wil be om case report forms.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 15 seconds
Measured by Near Infrared Spectroscopy
Time frame: 15 seconds
Glostrup University Hospital, Copenhagen
Other
Measuring the Cerebral Oxygen Saturation With NIRS Sensor Placed on the Forehead of Patients in the Prone Position. How Does the External Pressure Affect the Measurement.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07333703
Anaesthesia, Lumbosacral Spinal Stenosis
Samsun, Turkey (Türkiye)
View Trial DetailsNCT06976047
Anaesthesia, Anxiety
Damascus, Syria
View Trial DetailsNCT06724341
Anaesthesia, Anxiety
Damascus, Syrian Arab Republic, Syria
View Trial DetailsNCT04343807
Agnosia, Anaesthesia
Karachi, Sindh, Pakistan
View Trial Details