Subjects will be consented to wear the AleriTM sensor prior to, during, and after an Electrophysiology Procedure. During this time, the system will measure the following parameters from subjects: HR, temperature, saline volume/rate, urine production volume, USG, BPO. Data will be retrospectively analyzed to determine if the system effectively operates under these conditions, and can effectively monitor hydration levels of subjects compared to currently available methods.
Looking for future studies?
Notify Me18 year–100 year
All sexes
Interventional
Not applicable
New York, 10016, United States
Study subjects scheduled for an EP procedure who have signed an informed consent form (ICF) will be admitted to the study. Prior to the EP procedure (e.g. in a hospital room or operating room at NYU Medical Center), either an employee of NYU or Hydrostasis will place sensor on subject's bicep, forearm, or wrist, start the sensor and connect the sensor to mobile app to start data collection.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
AleriTM sensors are worn on the bicep or forearm and communicates through BLETM to a mobile App. The data is sent through the mobile App to web-based system processing where PHI is calculated and sent back to the mobile App.
The AleriTM sensor has a form factor similar to a conventional arm band, with a hockey puck shape of approximately 48mm in diameter and 15mm in thickness the AleriTM sensor is a non-significant risk (NSR) device as it does not meet the definition of significant risk device (21 CFR 812.3(m)) because it is: not an implant; is not purported or represented to support or sustain human life; its use is not of substantial importance in the diagnosis, cure, treatment, mitigation, or prevention of impairment of health; and it does not present a serious risk to the health, safety, or welfare of a subject.
Time frame: 1 hour pre-surgery, during surgery and 3-5 hours post-surgery
Study team will compare the hydration status (changes in body water content) as predicted by the Aleri sensor to changes in volume according to the routinely reported volume exchanges. This will be a correlation study, and as such the purpose would be to use Pearsons' correlation between the device measurement and the interval changes in fluids ingested or excreted by the patient. There is no benchmark, but rather we will be looking for statistically significant correlation for any r>.5.
NYU Langone Health
Other
Introductory Non-Clinical and Clinical Trial for Measuring Hydration Levels of Healthy and Heart Failure Patients Before, During, and After an Electrophysiology (EP) Procedure
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05298553
Arrhythmias, Cardiac, Atrial Fibrillation
Oxford, Oxfordshire, United Kingdom
View Trial DetailsNCT06172699
Ablation, Arrhythmias, Cardiac
San Diego, California, United States
View Trial DetailsNCT02241252
Arrhythmias, Cardiac, Cardiac Arrhythmia
Oklahoma City, Oklahoma, United States
View Trial DetailsNCT05772182
Arrhythmias, Cardiac, Cardiac Arrhythmia
Barcelona, Spain
View Trial Details