University of Calgary
Calgary, Alberta, Canada
NCT Number: NCT06157879
The goal of this observational study is to use a low-powered microwave imaging system to provide insight into the correlation of electrical properties of breast tissue at microwave frequencies and breast density obtained from mammograms in healthy women between the ages of 18 and 74. The main questions it aims to answer : • Is there a correlation between the electrical properties of breast tissue and breast density obtained from mammograms? Both breasts of each participant will be scanned by the microwave imaging system six times in total.
Looking for future studies?
Notify MeA new approach to imaging that uses low-power microwaves to scan the breast has been developed. Since the imaging system uses low power, there is no risk of tissue heating. The imaging system places the sensors in contact with the breast and does not require compression. The research team at the University of Calgary has previously developed microwave imaging systems that have been tested on volunteers and patients. This included repeated scanning of a group of volunteers to evaluate the consistency of the approach. The information collected from experiences scanning volunteers and patients have been reviewed and translated into a next-generation imaging system design. Aspects of this system have been further improved by Wave View Imaging, which is a company formed by members of the University's research team.
The proposed study involves collecting electrical property measurements of breast tissues and comparing these measurements to clinical information. The investigators also aim to compare regions of interest in the microwave scans with regions of interest in the mammograms. This includes regions dominated by fibroglandular tissues, as well as regions of interest that correspond to anomalies identified in the mammograms
The plan is to scan both breasts of up to 200 volunteers. Each volunteer will participate in a single scanning session. Breast tissue composition (VOLPARA score) will be compared with the microwave properties and registration of mammograms with microwave images will be performed for a more detailed comparison.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Microwave scans
Time frame: 18 months
The electrical properties will be estimated for each volunteer and an image that maps these properties will be created.
Time frame: 18 months
Comparison of the microwave images and mammograms in 2 ways: VOLPARA scores versus average electrical properties and comparison of regions of interest in both images
University of Calgary
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT06702423
Healthy
London, United Kingdom
View Trial DetailsNCT07223164
Healthy
Irvine, California, United States
View Trial DetailsNCT05595902
Healthy
Kadıköy, Istanbul, Turkey (Türkiye)
View Trial Details