The Children's Hospital of Philadelphia
Philadelphia, Pennsylvania, 19104, United States
NCT Number: NCT01265316
Outcomes for pediatric cardiopulmonary resuscitation (CPR) are suboptimal. CPR quality is directly related to resuscitation outcome, yet numerous deficiencies in CPR quality have been documented in adult studies. While similar deficiencies can be expected in pediatric resuscitation attempts, there is little to no data evaluating the existing quality of CPR performed during resuscitation attempts. Therefore, the objective of this study is to quantitatively evaluate existing CPR quality using a Q-CPR compression sensor manufactured by Philips Medical Systems with technology from Laerdal Medical.
Looking for future studies?
Notify Me1 year–7 year
All sexes
Observational
Philadelphia, Pennsylvania, 19104, United States
In the event of a cardiac arrest in the pediatric intensive care unit, a 24 hour paging system will notify the Cardiac Arrest Research Team to facilitate data collection. This system has been active as part of The Children's Hospital of Philadelphia (CHOP) Institutional Review Board (IRB) Protocol No. 2006-6-4839, and has resulted in capture of more than 95% of eligible events.
Cardiac arrest events requiring chest compressions in the PICU (pediatric intensive care unit) involving children greater than or equal to 1 year of age, but less than 8 years of age and who were previously screened, identified, and who have provided written consent are eligible for study. CPR quality will be recorded with the modified Heartstart MRx with Q-CPR Option, an external defibrillator with a chest compression sensor interposed between the hands of the rescuer providing chest compressions and the sternum of the patient. The device to be used is a regular Heartstart MRx with Quality of CPR (Q-CPR) Option cleared under 510(k) Premarket notification - K051134, but which has been modified for this study. In its current version, Q-CPR Option is approved for patients ≥ 8 years of age and has been utilized in the CHOP Pediatric Intensive Care Unit (PICU) under CHOP IRB Protocol No. 2006-6-4839. This Q-CPR Option on the Heartstart MRx has been modified for this study to accommodate children 1 year to less than 8 years of age. Since the device has been modified for use in this study, the device is an Investigational Device during this study regulated by the IDE regulation (CFR 21 Part 812). FDA has determined through a pre-investigational device exemption (IDE) process (I090674) that the use of the Heartstart MRx with the modified Q-CPR Option in a non-significant risk (NSR) device study. Two primary modifications were done on the Q-CPR Option: 1) changing the size of the compressions sensor footprint that interfaces with the patient's chest and 2) disabling the audiovisual Q-CPR feedback. Specifically the contact area of the compression sensor has been reduced to better mimic the area of the heel of a hand - the current recommended interface between the CPR administrator and the patient's chest during usual CPR / resuscitative care. Furthermore, no audiovisual feedback will be provided for this patient group as absolute measurement-based CPR quality targets do not exist for this age group. The device records CPR parameters (depth and rate of chest compressions), as well as electrocardiographic (ECG) data, and defibrillation shock data (if used). The pad relays this information to a recording component on the defibrillator which stores such data onto an internal data card. Once the cardiac arrest is completed, the MRx data can be exported to an external data card and downloaded to a secure laptop.
The investigator will use the Study Data Collection Form I in the Appendix to collect additional information immediately after resuscitation event has concluded. The patient's medical record will also be accessed and data will be collected as specified in the Medical Record Data Collection Form II. In addition to medical information, data collected will also include the post arrest chest depth in centimeters (cm) of the patient, chest circumference (cm) and details of the mattress and bed on which the child was resuscitated. Phase 2 procedures will be identical to those employed as per CHOP IRB Protocol No. 2006-6-4839.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Cardiac Arrest Inclusion Criteria
Clinical Staff Inclusion Criteria
Exclusion criteria
Cardiac Arrest Exclusion Criteria
There is no intervention for this study. The pre-NSR IDE for this study is simply a modification to allow for recording of data without intervention.
Time frame: 2 years
Time frame: 2 years
Children's Hospital of Philadelphia
Other
Pediatric CPR Quality: Quantitative Measurement of Pediatric Cardiopulmonary Resuscitation (CPR) Quality During In-Hospital Cardiac Arrest
Acronym: PediQ-CPR
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06836908
Cardiac Arrest, Cardiovascular Diseases
Vienna, Austria
View Trial DetailsNCT05756621
Cardiac Arrest, Cardiovascular Diseases
Brescia, BS, Italy
View Trial DetailsNCT02527031
Cardiac Arrest, Cardiovascular Diseases
Paris, France
View Trial DetailsNCT03817892
Cardiac Arrest, Cardiopulmonary Resuscitation
Caen, Normandy, France
View Trial Details