Completed

NCT Number: NCT04340648

Measurement Algorithm Control, Optimization, and Performance Evaluation of the Vital USA GlucoseDetect

Measurement Algorithm Control and Optimization with Subsequent Performance Evaluation of the Vital USA GlucoseDetect™ During a Standardized Meal Test in Patients with Diabetes mellitus Type 1 and Type 2

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–99 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Pfützner Science & Health Institute GmbH

Mainz, Rhineland-Palatinate, 55128, Germany

About this study

This study is a combined, open label, prospective, comparative single-center study.

The study is separated in 3 consecutive study parts. The first 2 study parts include 16 patients each. In the third study part 16 additional patients will be enrolled. Study part 1 and 2 will be used for optimization and validation of the measurement algorithms of the Vital USA biosensor. During the third study part with enrolment of 16 additional patients, the precision and accuracy of the final Vital USA biosensor algorithm will be demonstrated. The visit schedule for all participants of all 3 study parts will be exactly the same. In all groups of participants, the Vital USA non-invasive monitoring biosensor will be individually introduced and assigned. During the experimental study visit, a standardized meal will be given to the participants. Before and after the standardized meal, glucose, heart rate, and pO2 will be measured using the Vital USA monitoring biosensor at time-points -30, 0, 15, 30, 45, 60, 75, 90, 120, 150 and 180 min. The glucose measurements will be compared to capillary blood glucose measurements by YSI Stat 2300. Parallel measurements of the heart rate and the pO2 using a patient monitor will be compared to the device readings.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Type 1 or Type 2 diabetic or healthy subject (50 % from each)
  • Subjects who are able to complete informed consent form (by him/herself or by his/her guardian);
  • 18 years old and above;
  • Anatomically suitable finger in discretion of the investigator

Exclusion criteria

  • Does not meet inclusion criteria;
  • Any conditions that may hamper good visual contact between the finger or wrist and sensor, such as raised birthmarks, scars, tattoos;
  • Pregnancy;
  • Nursing mothers;
  • Any skin scratch(es), damage, over dry, long nails on the measured finger;
  • Unsuitable finger with the device might be excluded if recognized during the trial;
  • Medication containing nitrates

Treatment and study plan

Vital GlucoseDetect

Device

11 time points for blood glucose measurements over 210 min including the ingestion of a standardized meal 30 min after the first blood glucose measurement.

Primary outcomes

  1. Performance and accuracy in glucose monitoring and other parameters

    Time frame: 210 min

    Performance and accuracy in monitoring glucose levels (in mg/dL) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to the capillary blood glucose reference method YSI STAT 2300 (glucose in mg/dL).

  2. Performance and accuracy in pO2 monitoring

    Time frame: 210 min

    Performance and accuracy in monitoring pO2 levels (in mmHg) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to a patient monitor (pO2 (in mmHg).

  3. Performance and accuracy in pulse monitoring

    Time frame: 210 min

    Performance and accuracy in monitoring the pulse (in beats/min) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to a patient monitor (pulse (in beats/min).

Sponsors and collaborators

Lead sponsor

Sciema UG

Other

Registry information

Official study title

Measurement Algorithm Control and Optimization With Subsequent Performance Evaluation of the Vital USA GlucoseDetect™ During a Standardized Meal Test in Patients With Diabetes Mellitus Type 1 and Type 2

Important dates

Study start
2019
Primary completion
2019
Study completion
2019
First posted
Apr 9, 2020
Registry last updated
Apr 9, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.