Pfützner Science & Health Institute GmbH
Mainz, Rhineland-Palatinate, 55128, Germany
NCT Number: NCT04340648
Measurement Algorithm Control and Optimization with Subsequent Performance Evaluation of the Vital USA GlucoseDetect™ During a Standardized Meal Test in Patients with Diabetes mellitus Type 1 and Type 2
Looking for future studies?
Notify Me18 year–99 year
All sexes
Interventional
Not applicable
Mainz, Rhineland-Palatinate, 55128, Germany
This study is a combined, open label, prospective, comparative single-center study.
The study is separated in 3 consecutive study parts. The first 2 study parts include 16 patients each. In the third study part 16 additional patients will be enrolled. Study part 1 and 2 will be used for optimization and validation of the measurement algorithms of the Vital USA biosensor. During the third study part with enrolment of 16 additional patients, the precision and accuracy of the final Vital USA biosensor algorithm will be demonstrated. The visit schedule for all participants of all 3 study parts will be exactly the same. In all groups of participants, the Vital USA non-invasive monitoring biosensor will be individually introduced and assigned. During the experimental study visit, a standardized meal will be given to the participants. Before and after the standardized meal, glucose, heart rate, and pO2 will be measured using the Vital USA monitoring biosensor at time-points -30, 0, 15, 30, 45, 60, 75, 90, 120, 150 and 180 min. The glucose measurements will be compared to capillary blood glucose measurements by YSI Stat 2300. Parallel measurements of the heart rate and the pO2 using a patient monitor will be compared to the device readings.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
11 time points for blood glucose measurements over 210 min including the ingestion of a standardized meal 30 min after the first blood glucose measurement.
Time frame: 210 min
Performance and accuracy in monitoring glucose levels (in mg/dL) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to the capillary blood glucose reference method YSI STAT 2300 (glucose in mg/dL).
Time frame: 210 min
Performance and accuracy in monitoring pO2 levels (in mmHg) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to a patient monitor (pO2 (in mmHg).
Time frame: 210 min
Performance and accuracy in monitoring the pulse (in beats/min) using the GlucoseDetect during a standardized meal experiment. Measurements (during the meal experiment) of the GlucoseDetectTM will be compared to a patient monitor (pulse (in beats/min).
Sciema UG
Other
Measurement Algorithm Control and Optimization With Subsequent Performance Evaluation of the Vital USA GlucoseDetect™ During a Standardized Meal Test in Patients With Diabetes Mellitus Type 1 and Type 2
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00038727
Body Weight, CVD
Rockville, Maryland, United States
View Trial DetailsNCT06029517
Arterial Occlusive Diseases, Arteriosclerosis
Buffalo, New York, United States
View Trial DetailsNCT01934660
Cardiovascular Disease, Cardiovascular Diseases
Bethesda, Maryland, United States
View Trial DetailsNCT07728162
Diabetes Mellitus, Disease Attributes
Bolu, Turkey (Türkiye)
View Trial Details