Skip to main content
OpenTrials
Recruiting

NCT Number: NCT04028687

MDR - PMCF Study for Taperloc Complete Stems

The objective of this consecutive series PMCF study is to collect data confirming safety, performance, and clinical benefits of the Taperloc Complete stems when used for primary or revision total hip arthroplasty (implants) at 1,3,5,7 and 10-year follow-up*. Since Taperloc Complete was introduced to the EU in 2010, all available retrospective data will be collected from each patient and a prospective aspect to the study will be necessary to reach the 10-year time point.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Orthopaedic Institute of Henderson, Henderson, Nevada, United States

Loading trial locations.

About this study

The objective of this consecutive series PMCF study is to collect data confirming safety, performance, and clinical benefits of the Taperloc Complete stems when used for primary or revision total hip arthroplasty (implants) at 1,3,5,7 and 10-year follow-up*. Since Taperloc Complete was introduced to the EU in 2010, all available retrospective data will be collected from each patient and a prospective aspect to the study will be necessary to reach the 10-year time point.

The primary objective is to confirm safety of the study products. This will be assessed by recording the incidence and frequency of revisions, complications, and adverse events. Relationship of the events to either implant or instrumentation should be specified.

The secondary objective is the assessment of performance and clinical benefits by analyzing recorded patient-reported clinical outcomes measures (PROMs).

*The most recent available data will be used. If any of the listed time points are not available, data will be used from last available time point and follow-up will move forward at the closest available time point

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient must be 18 years of age or older and skeletally mature
  • Patient must be willing and able to sign IRB approved informed consent
  • Patient must have undergone primary or revision hip arthroplasty with the -Taperloc Complete stem according to a cleared indication, which includes the following:
  • Non-inflammatory degenerative joint disease including osteoarthritis and avascular necrosis
  • Rheumatoid arthritis
  • Correction of functional deformity
  • Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques

Exclusion criteria

  • Off-label use
  • Infection
  • Sepsis
  • Osteomyelitis
  • Uncooperative patient or patient with neurologic disorders who are incapable of following directions
  • Osteoporosis
  • Metabolic disorders which may impair bone formation
  • Osteomalacia
  • Distant foci of infections which may spread to the implant site
  • Rapid joint destruction, marked bone loss or bone resorption apparent on roentgenogram
  • Vascular insufficiency, muscular atrophy, or neuromuscular disease
  • Patient is known to be pregnant or nursing
  • Patient is a prisoner
  • Patient is a known alcohol or drug abuser
  • Patient has a psychiatric illness or cognitive deficit that will not allow for proper informed consent

Treatment and study plan

Taperloc Complete Stem

Device

Patients that have been implanted with a Taperloc Complete Stem to improve hip malfunction/disease.

Primary outcomes

  1. Device Safety assessed through the frequency and incidence of revisions, complications and Adverse Events.

    Time frame: Out to 10 Years

    The primary objective of this study is the assessment of safety by analyzing implant survivorship. This will be established by recording the incidence and frequency of revisions, complications and adverse events. Relation of the events to either implant or instrumentation should be specified.

Secondary outcomes

  1. Device Performance and Benefits evaluated through the Harris Hip Score

    Time frame: Out to 10 Years

    The HHS is divided into 4 sub-categories; pain (44 points), function (47 points), range of motion (5 points), and absence of deformity (4 points). Patients select a discrete set of answers which correspond to predefined point allocations based on the category. To obtain a final score, these values are summed.

  2. Device Performance and Benefits evaluated through the Oxford Hip Score

    Time frame: Out to 10 Years

    The OHS is a patient-completed, 12-question evaluation. Each item is scored from 1 to 5, with 1 representing best outcome/least symptoms and 5 representing worst outcome/most symptoms.

Study contacts

Contact information is provided by the study sponsor or research team.

Lynsey Boyle

CONTACT

[email protected]

+1 (412) 552-7111

Megan McKinnie

CONTACT

[email protected]

+1 (919) 381-7091

Sponsors and collaborators

Lead sponsor

Zimmer Biomet

Industry

Registry information

Official study title

Post Market Clinical Follow up Study to Provide Safety, Performance and Clinical Benefits Data of the Taperloc Complete Stems

Important dates

Study start
2020
Primary completion
2032
Study completion
2032
First posted
Jul 23, 2019
Registry last updated
Mar 11, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.