CRT-D (Medtronic)
DeviceBiventricular implantable cardioverter defibrillator, post marketing release
Other names: Medtronic CRT-D device
NCT Number: NCT01519908
The purpose of this study is to investigate: the relation of a set of (bio)markers and response to Cardiac Resynchronization Therapy (CRT); the interrelationship as well as the potential predictive power of these (bio)markers on improvement and/or deterioration of cardiac function, cardiac geometry (reverse re-modeling during CRT) will be evaluated.
(Bio)markers include but are not limited to: collagen, genomic markers, molecular markers, electrocardiographic markers, echocardiographic markers, arrhythmogenic markers and markers for renal function: blood urea nitrogen (BUN), serum creatinine, glomerular filtration rate (GFR).
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Academic Medical Center, Amsterdam, Netherlands
Title
MARC (Markers And Response to CRT) - Prospective CRT study
Sponsor and study management
The MARC study is being sponsored by all participants of the COHFAR project as being defined in the COHFAR project agreement (Medtronic, UMCU, AMC, MUMC, VUMC, UMCG and ICIN). Study management will be done by Medtronic.
Purpose
To investigate the relation of a set of (bio)markers and response to Cardiac Resynchronization Therapy (CRT); the interrelationship as well as the potential predictive power of these (bio)markers on improvement and/or deterioration of cardiac function, cardiac geometry (reverse re-modeling during CRT) will be evaluated.
(Bio)markers include but are not limited to: collagen, genomic markers, molecular markers, electrocardiographic markers, echocardiographic markers, arrhythmogenic markers and markers for renal function: blood urea nitrogen (BUN), serum creatinine, glomerular filtration rate (GFR).
Design:
This is a multi-center, exploratory, prospective, interventional post-market release, non-randomized, study.
Medical device:
For reasons of uniform therapy delivery and homogeneity of (device diagnostic) study data, only Medtronic CRT-Defibrillator devices are used in this study with CareLink transmission functionality, OptiVol and Cardiac Compass report. Any commercially available leads can be used upon discretion of the investigator. All CRT-D devices and additional components (leads, programmer) incorporated in this study are CE-marked and market-released devices and used within the intended use of these devices.
Objectives:
Primary objective
Secondary objectives
The biomarkers include:
All blood samples will be taken from peripheral venous blood and during implant also from the coronary sinus.
Additional prospective analysis:
Subject selection:
The study will enroll 240 symptomatic heart failure patients (NYHA functional class II-III) with a reduced left ventricular ejection fraction and a prolonged QRS duration as measured prior to implantation of a cardiac resynchronization device (CRT-D). All patients will be followed for 1 year after implant. Each patient will visit the clinical site at baseline, 1-month, 6-month and 12 month follow-up. The total study duration will be 3 years. The 5 participating clinical institutions are all located in the Netherlands and member of the COHFAR project which is a partnership of the Center for Translational Molecular Medicine (CTMM) and Universitair Medisch Centrum Utrecht (UMCU), Universitair Medisch Centrum Groningen (UMCG), Academisch Medisch Centrum (AMC), VU Medisch Centrum (VUMC), Maastricht Universitair Medisch Centrum (MUMC), Medtronic and MSD with support from the Dutch Heart Foundation.
Treatment:
Each study subject will receive cardiac resynchronization therapy (CRT-D) according to the ESC/AHA guidelines and per local hospital routine. Additionally, optimal medical therapy for heart failure is up to the investigator's discretion.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Biventricular implantable cardioverter defibrillator, post marketing release
Other names: Medtronic CRT-D device
Time frame: 6 months
To investigate the relationship between a set of (bio)markers and response to cardiac resynchronization therapy (as measured by echocardiography) at 6 months.
For each biomarker, the relation with LVESVi change between baseline and 6 months post implant will be analyzed.
Time frame: 12 months
Secondary objective 1
Time frame: 12 months
Secondary objective 2
Time frame: 12 months
Secondary objective 3
Time frame: 12 months
Secondary objective 4
Time frame: 12 months
Secondary objective 5
University Medical Center Groningen
Other
Acronym: MARC
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03446651
Cardiovascular Diseases, Heart Diseases
New Haven, Connecticut, United States
View Trial DetailsNCT05806606
Behavior, Cardiovascular Diseases
Hong Kong
View Trial DetailsNCT06847438
Cardiovascular Diseases, Heart Diseases
Atlanta, Georgia, United States
View Trial DetailsNCT07721909
Cardiovascular Diseases, Heart Diseases
Muscat, Oman
View Trial Details