Magnetic Resonance (MR) Spectroscopy in Localized Prostate Cancer

This study is designed to investigate whether filling the rectum with high density barium prior to a magnetic resonance spectroscopy (MRS)exam of the prostate improves the quality of the acquired spectrum. It is expected that the dense substance should help prevent air from entering the rectum and thus susceptibility artifacts in the obtained MRS data should be reduced. Ten patients with localized prostate cancer will be recruited for this study. There will be no change in treatment planning based on MRS study. Patient will receive standard radiation treatment prescribed by radiation oncologist.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Cross Cancer Institute

Edmonton, Alberta, T6G 1Z2, Canada

About this study

This study is designed to investigate whether filling the rectum with high density barium prior to a magnetic resonance spectroscopy (MRS) exam of the prostate improves the quality of the acquired spectrum. It is expected that the dense substance should help prevent air from entering the rectum and thus susceptibility artifacts in the obtained MRS data should be reduced. Ten patients with localized prostate cancer will be recruited for this study. There will be no change in treatment planning based on MRS study. Patient will receive standard radiation treatment prescribed by radiation oncologist.

An MRS study of each patient's prostate will be conducted with the 3 Tesla Philips Intera NMR (Nuclear Magnetic Resonance) scanners before and after filling the rectum with barium. Patients will be requested to take a mild laxative of their choice the night before the exam, and not to eat for 2-4 hours prior to the scan. To facilitate this, that patient's exam will be booked prior to lunch. Prior to the exam, the patient will be asked to empty their bladder and 40 mg of Buscopan will be administered to the patient (i.m. of i.v.) to reduce peristalsis, the presence of which degrades the quality of NMR scans. The patient will lie on a board designed to fit on the MR scanner patient bed and that holds one of the elements of the dual element phased array radiofrequency (RF) coil in place. The patient will be positioned such that the prostate is within the coil's field of view (preferably along its central axis); that is, the patient will lie on one element of the coil and the other element will be placed on top of the patients abdomen. An abdominal restraint will be placed around the patients abdomen to reduce breathing effects. After the patient has been centered in the magnet, MRI (Magnetic Resonance Imaging) images will be acquired to identify the tumor location. The positioning of the MRS voxel with the prostate will be carefully determined with the aid of a radiation oncologist. Preparation scans for the spectroscopy acquisition will be carried out prior to applying a PRESS (Point RESolved Spectroscopy) sequence that will be employed to obtain a proton (1H) spectrum of the prostate. The entire scan duration from preparation till completion will be approximately 30 minutes (5 minutes for patient positioning, 10 minutes for imaging and voxel placement, 5 minutes for spectroscope sequence preparation scans, and 10 minutes for spectrum acquisition). Following scan completion, the patient will have about 150 mL of Barium solution administered to the rectum. After standing for 3-4 minutes, the patient will like back on the NMR scanner bed and the same NMR procedure will be repeated again. The spectra acquired without and with the presence of Barium solution in the rectum will be compared to see if the latter situation is indeed advantageous.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Over 18 years
  • Localized prostate cancer patients
  • Signed informed consent form

Exclusion criteria

-

Treatment and study plan

3T MR Spectroscopy

Procedure

A Magnetic Resonance Spectroscopy (MRS)study of a patient's prostate will be conducted with the 3 Tesla Philips Intera Nuclear Magnetic Resonance (NMR) scanner before and after filling the rectum with barium. Scan duration from Preparation to Completion will be approximately 30 minutes. The spectra will be acquired without and with the presence of Barium solution to compare to see if the latter is advantageous.

Primary outcomes

  1. Imaging study to determine quality spectra on 3T MR

    Time frame: 1 Year

Sponsors and collaborators

Lead sponsor

AHS Cancer Control Alberta

Other

Registry information

Official study title

MR Spectroscopy in Localized Prostate Cancer

Important dates

Study start
2008
Primary completion
2014
Study completion
2014
First posted
Sep 22, 2008
Registry last updated
Jul 18, 2016