Duke University Medical Center
Durham, North Carolina, 27710, United States
NCT Number: NCT02019199
This study is a research initiative established to explore the use of magnetic resonance imaging (MRI) as a tool for detecting organ motion as it pertains to planning radiation therapy.
Looking for future studies?
Notify Me21 year and older
All sexes
Observational
Durham, North Carolina, 27710, United States
The goal with radiation therapy is to treat the defined tumor and spare the surrounding normal tissue from receiving dose above specified tolerance doses. There is evidence of improved local control and survival with higher doses of radiation, however, at the same time there is the need to spare normal tissues from higher doses of radiation. Technologies that allow the delivery of an increased radiation dose to the tumor while sparing normal tissue have the potential of improving the therapeutic ratio. However, the development of these technologies has been hampered by organ respiratory motion particularly in the case of the lungs and liver. Inadequate radiation coverage of a tumor secondary to organ motion can lead to delivering a lower dose to a portion of the tumor. Making the field of radiation larger to account for organ motion results in unnecessary radiation dose to surrounding healthy tissues. It is therefore desirable to document the extent of motion of the organ in question prior to carrying out the radiation treatment planning. The organ motion impacts directly on the radiation dose distribution in the treatment volume.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: During MRI approx 1 hour
MRI and CT ( all subjects will have a standard of care CT scan) data in DICOM format will be collected for analysis using commercial or customized - developed software. Image quality will be assessed based on signal-to-noise (SNR), contrast-to-noise ratio (CNR), and the presence of image artifacts. Data to be computed include, but are not limited to, tumor volumes (gross tumor volume, internal target volume, planning target volume, etc.), tumor motion parameters (range, trajectory, frequency, variation, probability distribution, etc.), and treatment plan parameters (target coverage, dose-volume-histogram, etc.).
Time frame: During MRI approx 1 hour
Free breathing/breath-hold MRI will be compared to free breathing/breath-hold CT
Time frame: During MRI approx 1 hour
Difference between CNR is measured by 4D-MRI and 4D-CT
Time frame: During MRI approx 1 hour
Difference between tumor motion as measured by 2D cine-MRI vs 4D-MRI vs 4D-CT
Duke University
Other
Magnetic Resonance Imaging ( MRI) for Radiation Therapy Treatment Planning Evaluation of Lung, Liver and Pancreatic Motion.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06582849
Adnexal Diseases, Anal Cancer
St Louis, Missouri, United States
View Trial DetailsNCT04825834
Bladder Cancer, Colonic Diseases
Homewood, Alabama, United States
View Trial DetailsNCT03199586
Adnexal Diseases, Advanced or Metastatic Treatment-refractory Solid Tumor Malignancies
Scottsdale, Arizona, United States
View Trial DetailsNCT03058289
Bile Duct Cancer, Bile Duct Diseases
Los Angeles, California, United States
View Trial Details