Magnetic Resonance Elastography and 2-Point Dixon MR Imaging Techniques in Diffuse Liver Disease

The goal of this clinical research study is to test the accuracy of magnetic resonance elastogram (MRE) and 2-point dixon magnetic resonance imaging (2PD MRI) using new computer software (called "phase correction algorithm") in patients who might have liver disease.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 1 / Phase 2

Primary location

University of Texas MD Anderson Cancer Center

Houston, Texas, 77030, United States

About this study

Finding liver damage as early as possible is important. Traditionally, biopsies have been used for this purpose. Biopsies are accurate but can only check a small part of the liver. Tissue fat and liver stiffness are common in patients with liver disease.This study is testing new MRI techniques (called an MRE) that may be able to test for these symptoms on the entire liver, in a short time.

A typical MRI uses a large magnet instead of x-rays to take pictures of the inside of your body. The MRE will be done on a standard MRI scanner.

Study Visit:

The MRE procedure is useful for identifying tissue stiffness. For the MRE procedure, you will lie on your back on the examination table, and a pneumatic driver (a light-weight, clear plastic drum, about 10 inches wide and 1 inch thick) will be placed over the upper abdomen. You will feel a vibration (like a cell phone or beeper vibrating). This vibration will create very small waves in the body. The scanner will then receive the vibrations from the liver and use them to create images of the liver tissue. The MRE will take about 40 seconds. The driver will only be turned on during this time.

Once the MRE is completed, you will then have a 2PD MRI scan while you are still lying on the table. This procedure is useful in identifying fat tissue. This will take about 20-60 seconds. The total exam time will be no more than 20 minutes, including the preparation time.

Once the MRI is completed, you will have a liver biopsy as part of your standard care. You will sign a separate consent form for this procedure.

After the biopsy is performed, your participation in the study will be complete.

This is an investigational study. The scanners and software for 2PD MRI used for this study are FDA-approved and being used in clinical practice. The MRE technique used for this study has not been FDA-approved. At this time, the MRE technique is being used in research only. The use of study data for the purpose of this study is investigational. Up to 60 patients will take part in this study. All will be enrolled at M. D. Anderson.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Group 1. Non-oncologic patients from VAMC in Houston:
  • Biopsy proven or clinically suspected advanced parenchymal liver disease
  • Core biopsies obtained within 1-month of MRI/MRE
  • No treatment affecting the status of liver between MRI/MRE and post-imaging biopsy
  • Signed consent
  • Group 2. Oncologic patients at MDACC:
  • Clinically or radiographically suspected liver damage, hepatic steatosis, hepatitis, hepatic fibrosis or cirrhosis
  • Surgical or core biopsy scheduled within 4 weeks of MRI/MRE
  • Signed consent

Exclusion criteria

  • Claustrophobia
  • Contraindications for MRI
  • Unable to hold a breath
  • Ascites or other clinical or radiographical signs of portal hypertension

Treatment and study plan

Magnetic Resonance Elastogram

Diagnostic Test

Pneumatic driver will be placed over the upper abdomen. Patient will feel a vibration (like a cell phone or beeper vibrating). This vibration will create very small waves in the body. The scanner will then receive the vibrations from the liver and use them to create images of the liver tissue.

Other names: MRE

2-Point Dixon Magnetic Resonance Imaging

Diagnostic Test

Imaging performed after the MRE procedure and lasting 20-60 seconds. This procedure is useful in identifying fat tissue.

Other names: 2PD MRI

Primary outcomes

  1. Overall Image Quality of Magnetic Resonance Elastography (MRE)

    Time frame: 2 Years

Secondary outcomes

  1. Association Between Degrees of Stiffness Measured by MRE in kPa and Histopathological Grades of Fibrosis and Steatohepatitis

    Time frame: Baseline to end of trial, up to 2 years

    Assessed using Pearson correlation

  2. Hepatic Steatosis

    Time frame: Baseline to the end of the trial, up to 2 years

    Development of a non-invasive means to quantify hepatic steatosis using 2-Point Dixon technique for patients with >30% steatosis compared to participants with <30% steatosis. The degree of steatosis was quantified by percent fat fraction (%FF).

Sponsors and collaborators

Lead sponsor

M.D. Anderson Cancer Center

Other

Registry information

Official study title

Validation Study of Magnetic Resonance Elastography and 2-Point Dixon MR Imaging Techniques in Diffuse Liver Disease

Important dates

Study start
2007
Primary completion
2020
Study completion
2020
First posted
Oct 15, 2007
Registry last updated
Apr 13, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.