NCT Number: NCT03117686
High altitude pulmonary edema is a life-threatening condition that remains a concern for climbers and clinicians alike. It is defined as a non-cardiac pulmonary edema occurring at altitudes exceeding 3000m in non-acclimatised individuals. Recently, studies conducted in remote areas have demonstrated that ultrasound lung comets (B lines) can be used as a measure of sub-acute pulmonary edema and high altitude pulmonary edema in climbers ascending to altitude. the investigators want to assess the occurrence of of comet tails (B lines) as a measure of pulmonary edema among patients after lung transplantation and healthy individuals during an expedition to Mount Kilimanjaro.
Looking for future studies?
Notify Me18 year–99 year
All sexes
Observational
Vienna, 1090, Austria
High altitude pulmonary edema is a life-threatening condition that remains a concern for climbers and clinicians alike. It is defined as a non-cardiac pulmonary edema occurring at altitudes exceeding 3000m in non-acclimatised individuals. Within the last decade, studies have shown ultrasonography to be valuable in the accurate diagnosis of a variety of lung pathologies, including cardiogenic pulmonary edema, pleural effusion, pneumothorax, and lung consolidation. Recently, studies conducted in remote areas have demonstrated that ultrasound lung comets (B lines) can be used as a measure of sub-acute pulmonary edema and high altitude pulmonary edema in climbers ascending to altitude. These studies also demonstrated that small portable ultrasound devices are reliable at high altitude in a cold and hypobaric environment.
So far all studies concerning the detection of comet tails as a measure of pulmonary edema have been done only in a healthy population. There is no study evaluating this topic in patients after lung transplantation.
Study objectives (Hypothesis)
The investigators want to assess the occurrence of of comet tails (B lines) as a measure of pulmonary edema among patients after lung transplantation and healthy individuals during an expedition to Mount Kilimanjaro.
Study design
Prospective observational single-center study.
Study population
10 patients > 2 years after lung transplantation and 10 healthy volunteers
Methods
The investigators will do the ultrasound examinations using the portable V-scan ultrasonography device (GE Healthcare) with a dual probe, including a phased array cardiac probe on one side and a linear probe on the other side.
Examinations will be done at sea level (before and right after the expedition), on the 3rd day at Shira hut at 3840 m and on the 6th day at Barafu camp at 4600m (highest camp site before summiting). Examinations will be done at the camp sites in a tent to assure good examination conditions for the patients.
Lung ultrasound will be performed with the patient in supine position. The phased-array transducer will be used for lung ultrasound, and will be used for the assessment of B-lines, which arise from the pleural line to the bottom of the screen and move with the sliding lung. The investigators will quantify the B- line burden in lung regions using the validated Eight-region method: Each hemithorax is divided into four quadrants, upper and lower anterior and upper and lower lateral divided longitudinally by the anterior axillary line and transversely by the 2nd intercostal space. If 3 or more B-lines (any size and spaced apart by any distance) are present in a particular region, that region is considered positive. Two or more positive regions per side define a "B-line pattern."
Measurement of optic nerve sheath diameter will be performed with a linear transducer placed superior and lateral to the eye, above the upper eyelid. The patient will be positioned supine, with a 30 degree head elevation. After visualization of the entry of the optic nerve into the globe, we will freeze the image. Optic nerve sheath diameter will be measured 3mm behind the globe in a perpendicular axis to the nerve. Two measurements will be taken per eye, and the mean of the 4 values will represent the optic nerve sheath diameter. A nerve sheath diameter of more than 5.8mm is defined as equivalent with an intracranial pressure (ICP) of more than 20mmHg.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
lung ultrasound with positive "B-line pattern" in patients after lung transplantations and healthy volunteers at sea level and high altitude (4600 m) at Mountb Kilimanjaro
Time frame: 2 weeks
Positive "B-line pattern" in patients after lung transplantations and healthy volunteers at sea level and high altitude (4600 m)
Time frame: 2 weeks
optic nerve sheath diameter in patients after lung transplantations and healthy volunteers at sea level and high altitude (4600 m)
Medical University of Vienna
Other
Estimation of Pulmonary Arterial Pressure With Transesophageal Echocardiography: A Pilot Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05131945
Bronchial Diseases, Bronchiolitis
Houston, Texas, United States
View Trial DetailsNCT05594485
Artificial Intelligence, Atelectasis
Havířov, Czechia
View Trial DetailsNCT03576092
Female Urogenital Diseases and Pregnancy Complications, Lung Diseases
View Trial DetailsNCT04660448
Acute Respiratory Distress Syndrome, Extravascular Lung Water
Oviedo, Principality of Asturias, Spain
View Trial Details