LKS Faculty of Medicine
Hong Kong
NCT Number: NCT03904810
Background: The relationship between the frequency of high-intensity interval training (HIIT) and the resultant adaptations is largely unclear. Purpose: This study examined the effects of different frequencies of HIIT compared to moderate-intensity continuous training (MICT) on body composition and cardiovascular biomarkers in overweight or obese adults. Methods: This study was a randomized, controlled, single-blinded trial. Fifty-six overweight or obese men aged between 18 and 30 years were randomly assigned to no-intervention control (CON; n=14), MICT performed thrice weekly (MICT×3/wk; n=9), HIIT performed thrice weekly (HIIT×3/wk; n=14), HIIT performed twice weekly (HIIT×2/wk; n=10), and HIIT performed once weekly (HIIT×1/wk; n=9). Each HIIT session consisted of 12 × 1-min bouts at 90% heart rate reserve (HRR), interspersed with 11 × 1-min bouts at 70% HRR (HIIT×3/wk: 69 min/wk; HIIT×2/wk: 46 min/wk; HIIT×1/wk: 23 min/wk). Aerobic capacity, resting heart rate, body composition, waist circumference, blood pressure, endothelial function, fasting blood glucose and lipids, circulatory adipokines and inflammatory biomarkers were examined at baseline, after 4 weeks and 8 weeks of intervention.
Looking for future studies?
Notify Me18 year–30 year
Male
Interventional
Not applicable
Hong Kong
Individuals who fulfilled the following inclusion criteria were invited to participate in the present study: 1) Chinese male; 2) aged 18-30 years; and 3) overweight or obesity, defined as BMI ≥23 kg/m2 (classification of overweight for Hong Kong adults according to Department of Health, Hong Kong SAR Government) (13). Subjects were excluded if they had: 1) chronic medical and health condition such as cardiovascular diseases, diabetes, neurological disease, musculoskeletal disorder, cancers, and autoimmune diseases; 2) hypertension (blood pressure >140/90 mmHg); 3) contraindications to participating in physical exercise; 4) any pre-existing medical or physical issues that affected the experimental test; 5) physically active (i.e., >3 hours of moderate-intensity exercise weekly) or 6) lean overweight population (BMI ≥23 kg/m2, but percent body fat ≤20%) according to the BMI data corresponding to bioelectrical impedance estimated percent body fat cut-off value among Hong Kong Chinese adults.
Of those who were screened, 103 Chinese young adults were eligible to participate in this study. They were provided with written and verbal information on the study protocol and the possible associated discomforts and risks followed by obtaining their written informed consent to participate in this study. The study protocol and consent form were approved by the Human Subjects Ethics Sub-Committee of The Hong Kong Polytechnic University (ethics approval reference number: HSEARS20160927005-01).
This study was a single-blind, randomized, controlled trial. Subjects were randomly assigned to 1) no-intervention control (CON), 2) MICT performed thrice weekly (MICTx3/wk), 3) HIIT performed thrice weekly (HIITx3/wk), 4) twice weekly (HIITx2/wk), and 5) once weekly (HIITx1/wk). All subjects were instructed to maintain their usual daily activities. Outcome measures including aerobic capacity, body composition, blood pressure, resting heart rate, endothelial function, arterial stiffness, fasting glucose, lipids markers, adipokine marker, and inflammatory marker were assessed at baseline, 4 weeks and 8 weeks after the intervention.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
HIIT groups performed 30-meter shuttle runs on a rooftop covered field whereas MICT group ran on a footpath with an overall flat and non-slippery road surface. All training sessions were preceded by a 5-minute self-pace warm-up jogging and ended with a 5-minute self-pace jogging or walking cool-down. Each session of MICT consisted of 30 minutes of continuous exercise at an intensity of 60% of heart rate reserve (HRR); [i.e., (maximal HR - resting HR) × intensity + resting HR]. For each HIIT session, the intensity was set at 90% HRR for high-intensity bouts, interspersed with active recovery at 70% HRR. All exercise sessions were supervised by qualified athletic coach or strength and conditioning coach.
Time frame: 8 weeks
Estimated maximal oxygen consumption achieved during the 20-meter shuttle multistage run test were used for the assessment of aerobic fitness Unit: body weight, estimated oxygen consumption and minute will be combined to report the estimated VO2max in ml/kg/min.
Time frame: 8 weeks
Total running distance in meters achieved during the 20-meter shuttle multistage run test were used for the assessment of aerobic fitness
Time frame: 8 weeks
Total body fat percentage were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Total body fat mass in kg were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Total body fat-free mass percentage were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Total body fat-free mass were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Trunk fat mass in kg were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Body weight in kg were assessed by a bioelectrical impedance analyzer (BC-418, Tanita, Japan).
Time frame: 8 weeks
Body height in meter were assessed.
Time frame: 8 weeks
Weight and height will be combined to report BMI in kg/m^2
Time frame: 8 weeks
Waist circumference was determined to the nearest 0.1 cm of a contact tension tape. The tape was applied directly to the skin at the mid-point between the lower margin of the last palpable rib and the top of the iliac crest.
Time frame: 8 weeks
Systolic blood pressure was determined by an electronic sphygmomanometer (Accutorr Plus, Datascope, USA)
Time frame: 8 weeks
Diastolic blood pressure was determined by an electronic sphygmomanometer (Accutorr Plus, Datascope, USA)
Time frame: 8 weeks
Mean arterial pressure was determined by an electronic sphygmomanometer (Accutorr Plus, Datascope, USA)
Time frame: 8 weeks
Resting heart rate was determined by an electronic sphygmomanometer (Accutorr Plus, Datascope, USA)
Time frame: 8 weeks
Endothelial function were measured by digital plethysmography using EndoPAT 2000 device (ITAMAR Medical, Caesarea, Israel) and expressed as natural log reactive hyperemia index (LnRHI)
Time frame: 8 weeks
Arterial stiffness were measured by digital plethysmography using EndoPAT 2000 device (ITAMAR Medical, Caesarea, Israel) and expressed as augmentation index normalized to heart rate of 75 bpm (AI@75)
Time frame: 8 weeks
Fresh blood samples were sent to an accredited medical laboratory to measure the serum fasting glucose concentrations by commercial test kit methods with an automatic clinical chemistry analyzer (Architect CI8200, Abbott Diagnostics, USA)
Time frame: 8 weeks
Fresh blood samples were sent to an accredited medical laboratory to measure the serum triglycerides concentrations by commercial test kit methods with an automatic clinical chemistry analyzer (Architect CI8200, Abbott Diagnostics, USA)
Time frame: 8 weeks
Fresh blood samples were sent to an accredited medical laboratory to measure the serum high-density lipoproteins-cholesterol (HDL-C) concentrations by commercial test kit methods with an automatic clinical chemistry analyzer (Architect CI8200, Abbott Diagnostics, USA)
Time frame: 8 weeks
Low-density lipoprotein (LDL) cholesterol in serum was measured by an automatic chemistry analyzer (AU-480, Beckman Coulter, USA)
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine interleukin 6
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine tumor necrosis factor alpha
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine c-reactive protein
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine adiponectin
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine intercellular adhesion molecule-1
Time frame: 8 weeks
Commercially available enzyme-linked immunosorbent assay kits (R&D systems, Minneapolis, MN) were used to determine vascular cell adhesion molecule-1
The University of Hong Kong
Other
The Effectiveness of Low-frequency High-Intensity Interval Training (HIIT) in Overweight or Obese Young Adults
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02075710
Body Weight, Nutrition Disorders
San Francisco, California, United States
View Trial DetailsNCT07717814
Body Weight, Nutrition Disorders
Anaheim, California, United States
View Trial DetailsNCT07313761
Body Weight, Nutrition Disorders
Anaheim, California, United States
View Trial DetailsNCT05330247
Body Weight, Diabetes Mellitus
Copenhagen, Copenhagen NV, Denmark
View Trial Details