Low Add Multifocal Versus Extended Depth of Focus Intraocular Lens

The innovations in phacoemulsification surgery and advances in surgical equipment ensure a safe extraction of the crystalline lens and implantation of intraocular lenses (IOL). As a result of developing intraocular lens technologies and changing patient demands, many multifocal, accommodative, toric, toric-multifocal, and extended depth of focus (EDOF) IOLs have been introduced and the original aim of restoration of far vision with implanted monocular IOLs has been evolved to an objective of improved vision at different distances with total spectacle independence. This study aimed to compare the visual acuity at different distances, contrast sensitivity, spectacle needs, photic phenomena, and quality of life parameters of patients bilaterally implanted with a low add bifocal (Tecnis ZKB00) or an EDOF IOL (Tecnis Symfony), both with planned mini-monovision to improve near vision.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Marmara University School of Medicine, Department of Ophthalmology

Istanbul, 34854, Turkey (Türkiye)

About this study

The innovations in phacoemulsification surgery and advances in surgical equipment ensure a safe extraction of the crystalline lens and implantation of intraocular lenses (IOL). As a result of developing intraocular lens technologies and changing patient demands, many multifocal, accommodative, toric, toric-multifocal, and extended depth of focus (EDOF) IOLs have been introduced and the original aim of restoration of far vision with implanted monocular IOLs has been evolved to an objective of improved vision at different distances with total spectacle independence. This study aimed to compare the visual acuity at different distances, contrast sensitivity, spectacle needs, photic phenomena, and quality of life parameters of patients bilaterally implanted with a low add bifocal (Tecnis ZKB00) or an EDOF IOL (Tecnis Symfony), both with planned mini-monovision to improve near vision. In this regard, binocular logMAR uncorrected visual acuities (UVA), monocular defocus curves, CS with CSV 1000-E and Pelli-Robson Test (PRT), spectacle needs and quality of life parameters with NEI RQL-42 questionnaire were evaluated at postoperative 1, 3, and 6 months.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Inclusion criteria

were patients with bilateral visually significant cataract seeking spectacle independence, especially at far and intermediate distances, age of ≥18 years, preoperative corneal astigmatism less than 1.00 D, axial length (AL) between 21 - 26.5 mm, and availability to attend all follow-up visits.

Exclusion criteria

Patients were excluded from the study if any of the following conditions were present: high visual demand for near vision, amblyopia, glaucoma, corneal opacity, severe/moderate to severe dry eye, pupillary abnormalities and dysfunction, corneal astigmatism ≥1.00 D, AL <21 mm or ≥26.5 mm, diabetes mellitus with retinal changes, active uveitis or history of uveitis, previous ocular surgery and lack of attendance to any follow-up visit.

Treatment and study plan

Tecnis +2.75 D (ZKB00) and Tecnis Symfony (ZXR00)

Device

This study included 30 eyes of 15 cataract patients undergoing cataract surgery with implantation of a low add (+2.75 Diopters [D]) bifocal (Tecnis ZKB00; Johnson and Johnson Surgical Vision Inc., Jacksonville, Florida, USA) IOL (MIOL Group) and 30 eyes of 15 patients with implantation of an EDOF (Tecnis Symfony [ZXR00]; Johnson and Johnson Surgical Vision Inc., Jacksonville, Florida, USA) IOL (EDOF Group).

Primary outcomes

  1. The visual acuity

    Time frame: Preoperative

    monocular and binocular uncorrected and corrected distance (UDVA, CDVA; at 6 m), intermediate (UIVA, CIVA; at 60 cm), and near (UNVA, CNVA; at 40 cm) logMAR visual acuity were assessed with electronic shelled chart.Distance visual acuity was measured with LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Snellen Charts under photopic conditions (85 cd/m2). Intermediate and near visual acuities were measured and recorded with a Turkish reading chart prepared with reference to Bailey-Lovie and ETDRS (Early Treatment Diabetic Retinopathy Study) reading charts covering international standards.13 The logMAR values of the chart designed for 35 cm distance were corrected with the formula "log10(standard distance/new distance [cm])" according to the distance used (40 and 60 cm).

  2. The visual acuity

    Time frame: Postoperative 1st month

    monocular and binocular uncorrected and corrected distance (UDVA, CDVA; at 6 m), intermediate (UIVA, CIVA; at 60 cm), and near (UNVA, CNVA; at 40 cm) logMAR visual acuity were assessed with electronic shelled chart.Distance visual acuity was measured with LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Snellen Charts under photopic conditions (85 cd/m2). Intermediate and near visual acuities were measured and recorded with a Turkish reading chart prepared with reference to Bailey-Lovie and ETDRS (Early Treatment Diabetic Retinopathy Study) reading charts covering international standards.13 The logMAR values of the chart designed for 35 cm distance were corrected with the formula "log10(standard distance/new distance [cm])" according to the distance used (40 and 60 cm).

  3. The visual acuity

    Time frame: Postoperative 3rd month

    monocular and binocular uncorrected and corrected distance (UDVA, CDVA; at 6 m), intermediate (UIVA, CIVA; at 60 cm), and near (UNVA, CNVA; at 40 cm) logMAR visual acuity were assessed with electronic shelled chart.Distance visual acuity was measured with LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Snellen Charts under photopic conditions (85 cd/m2). Intermediate and near visual acuities were measured and recorded with a Turkish reading chart prepared with reference to Bailey-Lovie and ETDRS (Early Treatment Diabetic Retinopathy Study) reading charts covering international standards.13 The logMAR values of the chart designed for 35 cm distance were corrected with the formula "log10(standard distance/new distance [cm])" according to the distance used (40 and 60 cm).

  4. The visual acuity

    Time frame: Postoperative 6th month

    monocular and binocular uncorrected and corrected distance (UDVA, CDVA; at 6 m), intermediate (UIVA, CIVA; at 60 cm), and near (UNVA, CNVA; at 40 cm) logMAR visual acuity were assessed with electronic shelled chart.Distance visual acuity was measured with LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Snellen Charts under photopic conditions (85 cd/m2). Intermediate and near visual acuities were measured and recorded with a Turkish reading chart prepared with reference to Bailey-Lovie and ETDRS (Early Treatment Diabetic Retinopathy Study) reading charts covering international standards.13 The logMAR values of the chart designed for 35 cm distance were corrected with the formula "log10(standard distance/new distance [cm])" according to the distance used (40 and 60 cm).

  5. The contrast sensitivity (CS),

    Time frame: Preoperative

    Contrast sensitivity (CS) was evaluated at 3, 6, 12 and 18 cycle per degree (cpd) spatial frequencies with CSV-1000 E test (VectorVision, Ohio, USA) under mesopic (3.5 candela [cd]/m2) conditions at 2.5 m with distance refractive correction. The test was conducted with and without glare, and as a glare source, two halogen lamps located either side of the test chart and producing 2.5 cd/m2 luminance at eye plane were used. CS at different spatial frequencies was compared with the physiologic CS range for normal subjects of similar age. CS was also evaluated with the LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Pelli-Robson Test (PRT) under photopic (85 cd/m2) and mesopic (3.5 cd/m2) conditions at 3 m monocularly with distance refractive correction. To the best of our knowledge, PRT CS normal values, performed under similar conditions, are not available in the literature, so the data was used only for intergroup comparisons.

  6. The contrast sensitivity (CS),

    Time frame: Postoperative 1st month

    Contrast sensitivity (CS) was evaluated at 3, 6, 12 and 18 cycle per degree (cpd) spatial frequencies with CSV-1000 E test (VectorVision, Ohio, USA) under mesopic (3.5 candela [cd]/m2) conditions at 2.5 m with distance refractive correction. The test was conducted with and without glare, and as a glare source, two halogen lamps located either side of the test chart and producing 2.5 cd/m2 luminance at eye plane were used. CS at different spatial frequencies was compared with the physiologic CS range for normal subjects of similar age. CS was also evaluated with the LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Pelli-Robson Test (PRT) under photopic (85 cd/m2) and mesopic (3.5 cd/m2) conditions at 3 m monocularly with distance refractive correction. To the best of our knowledge, PRT CS normal values, performed under similar conditions, are not available in the literature, so the data was used only for intergroup comparisons.

  7. The contrast sensitivity (CS),

    Time frame: Postoperative 3rd month

    Contrast sensitivity (CS) was evaluated at 3, 6, 12 and 18 cycle per degree (cpd) spatial frequencies with CSV-1000 E test (VectorVision, Ohio, USA) under mesopic (3.5 candela [cd]/m2) conditions at 2.5 m with distance refractive correction. The test was conducted with and without glare, and as a glare source, two halogen lamps located either side of the test chart and producing 2.5 cd/m2 luminance at eye plane were used. CS at different spatial frequencies was compared with the physiologic CS range for normal subjects of similar age. CS was also evaluated with the LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Pelli-Robson Test (PRT) under photopic (85 cd/m2) and mesopic (3.5 cd/m2) conditions at 3 m monocularly with distance refractive correction. To the best of our knowledge, PRT CS normal values, performed under similar conditions, are not available in the literature, so the data was used only for intergroup comparisons.

  8. The contrast sensitivity (CS),

    Time frame: Postoperative 6th month

    Contrast sensitivity (CS) was evaluated at 3, 6, 12 and 18 cycle per degree (cpd) spatial frequencies with CSV-1000 E test (VectorVision, Ohio, USA) under mesopic (3.5 candela [cd]/m2) conditions at 2.5 m with distance refractive correction. The test was conducted with and without glare, and as a glare source, two halogen lamps located either side of the test chart and producing 2.5 cd/m2 luminance at eye plane were used. CS at different spatial frequencies was compared with the physiologic CS range for normal subjects of similar age. CS was also evaluated with the LCD screen version (CSO Vision Chart, Mod CVC02, version 1.3.0, Florence, Italy) of Pelli-Robson Test (PRT) under photopic (85 cd/m2) and mesopic (3.5 cd/m2) conditions at 3 m monocularly with distance refractive correction. To the best of our knowledge, PRT CS normal values, performed under similar conditions, are not available in the literature, so the data was used only for intergroup comparisons.

  9. Quality of life measurement

    Time frame: Preoperative

    Quality of life parameters were evaluated by the validated Turkish version of the National Eye Institute Refractive Error Quality of Life Instrument 42 (NEI RQL-42) questionnaire. It includes 13 subscales of quality of life parameters calculated according to a scoring key, and a "total score" can be obtained by calculating the mean value of all 42 questions.

  10. Quality of life measurement

    Time frame: Postoperative 1st month

    Quality of life parameters were evaluated by the validated Turkish version of the National Eye Institute Refractive Error Quality of Life Instrument 42 (NEI RQL-42) questionnaire. It includes 13 subscales of quality of life parameters calculated according to a scoring key, and a "total score" can be obtained by calculating the mean value of all 42 questions.

  11. Quality of life measurement

    Time frame: Postoperative 3rd month

    Quality of life parameters were evaluated by the validated Turkish version of the National Eye Institute Refractive Error Quality of Life Instrument 42 (NEI RQL-42) questionnaire. It includes 13 subscales of quality of life parameters calculated according to a scoring key, and a "total score" can be obtained by calculating the mean value of all 42 questions.

  12. Quality of life measurement

    Time frame: Postoperative 6th month

    Quality of life parameters were evaluated by the validated Turkish version of the National Eye Institute Refractive Error Quality of Life Instrument 42 (NEI RQL-42) questionnaire. It includes 13 subscales of quality of life parameters calculated according to a scoring key, and a "total score" can be obtained by calculating the mean value of all 42 questions.

Sponsors and collaborators

Lead sponsor

Marmara University

Other

Registry information

Official study title

Clinical Outcomes With a Low Add Multifocal and an Extended Depth of Focus Intraocular Lenses Both Implanted With Mini-monovision

Important dates

Study start
2016
Primary completion
2018
Study completion
2019
First posted
Apr 29, 2021
Registry last updated
Apr 29, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.