Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06691555

Long-term Safety and Efficacy of a Modified Suprachoroidal Silicone Tube (SST) Shunt

The goal of this observational study is to evaluate the long-term safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in treating patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG).

The main questions it aims to answer are:

Does the SST shunt maintain intraocular pressure (IOP) reduction over an extended follow-up period? What is the effect of the SST shunt on endothelial cell count (ECC) and overall corneal health?

Participants will:

Undergo intraocular pressure (IOP) measurements Have their endothelial cell count (ECC) evaluated Complete assessments of best corrected visual acuity (BCVA) Be assessed for C/D ratio Be monitored for adverse events or shunt-related complications over time

Recruiting

Interested in participating?

Request Info

Key information

Age range

40 year–90 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Davinci Eye Center, LTD

Tbilisi, 0160, Georgia

Location status: Recruiting

Location contact

Nikoloz Labauri, MD. FVRS

CONTACT

[email protected]

+995599003744

About this study

This observational study serves as an extension to a prior retrospective cross-sectional trial that initially investigated the clinical outcomes of suprachoroidal silicone tube (SST) shunt implantation in patients diagnosed with primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PXG). In the initial study, participants underwent the SST shunt procedure and were followed for an average period of 19 months post-surgery. This initial study focused on assessing intraocular pressure (IOP) reduction and the initial safety profile of the SST device. However, as the device's long-term impact on ocular health, particularly the corneal endothelium, was not fully understood, this follow-up observational study was designed and implemented approximately 1 year after the last FU data collection was completed.

The SST shunt device is a relatively novel intervention positioned between minimally invasive glaucoma surgeries (MIGS) and traditional tube shunt surgeries. By facilitating aqueous humor drainage from the anterior chamber to the suprachoroidal space, the SST shunt provides a unique pathway for IOP reduction. Given the risks associated with corneal endothelial health in glaucoma patients, especially following invasive procedures, understanding the long-term impact of the SST shunt on endothelial cell counts (ECC) is essential.

Study Objectives:

The primary objective of this observational study is to evaluate the long-term safety and efficacy of the SST shunt in reducing IOP and preserving endothelial cell health. This involves:

Tracking changes in ECC attributable solely to the SST shunt, as the study design excluded additional interventions to isolate the device's effect.

Assessing the device's ability to maintain effective IOP control over an extended period.

Documenting any adverse events, including device migration, extrusion, and other complications, to understand the SST shunt's overall impact on ocular health.

Study Population:

The study is going to re-evaluate approximately 66 eyes, who had previously undergone SST shunt implantation, either as a standalone procedure or in combination with cataract surgery. These evaluations are going to be conducted within the period between 8 Nov/2024 and 30 Nov/2024.Participants in this observational study met the original inclusion criteria set forth in the retrospective trial. This included a cohort of Caucasian patients aged 41 to 88 years (mean age: 69), with a gender distribution of 40 men and 26 women. All patients were untreated with glaucoma surgeries or laser therapies prior to the SST implantation, providing a clean baseline for evaluating the SST device's isolated effects.

Study Design:

This study is observational and non-interventional, meaning it involved no additional treatments or manipulations beyond the baseline SST shunt implantation. This approach allowed for a naturalistic assessment of ECC and other clinical parameters over time. By not introducing any new variables, the study design aimed to observe and measure outcomes that could be directly attributed to the SST shunt. This design offers valuable insights into the natural progression of endothelial cell health and IOP management in patients who have undergone SST implantation without the influence of confounding factors.

Clinical Assessments and Follow-Up Procedures With an average 31 months (std. dev: 8 monts) follow-up, participants underwent assessments to monitor IOP, visual acuity, ECC, C/D ratio and any shunt-related adverse events.

Outcome Measures:

Primary Outcomes:

Endothelial Cell Loss: Tracked to assess corneal integrity. IOP Control: Success was defined as ≥20% reduction in IOP, with "complete success" for IOP control without medications, "qualified success" with medications, and "failure" for <20% IOP reduction or IOP >21 mmHg.

Secondary Outcomes:

Hypotony: Defined as IOP <5 mmHg, categorized as transient or permanent. Device Migration/Extrusion: Monitored to assess mechanical stability. Other Adverse Events: Any device-related complications documented for safety analysis.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Previously were treated with Suprachoroidal silicone tube shunt
  • Willing and able to participate in this cross sectional observational follow up
  • Participant capable of giving informed consent

Exclusion criteria

  • Condition that could impact the ability of the participant to attend a follow-up visit as per the discretion of the investigator

Treatment and study plan

Suprachoroidal silicone tube (SST) shunt

Device

This intervention involves implanting a modified suprachoroidal silicone tube (SST) shunt, derived from the Aurolab Aqueous Drainage Device (AADI), to lower intraocular pressure in patients with primary open-angle and pseudoexfoliative glaucoma. The SST shunt, measuring 13.0-15.0 mm with a 0.3 mm inner and 0.6 mm outer diameter, is designed to reach the posterior suprachoroidal space. Six slits near the distal end aid aqueous outflow. Implantation involves creating a scleral flap, accessing the SCS, and placing the distal end in the SCS and proximal end in the anterior chamber (AC). The shunt is secured with sutures, and viscoelastic is injected into the AC to prevent hypotony. No antimetabolites or cautery are used.

Primary outcomes

  1. Endothelial Cell Loss

    Time frame: From enrollment to the end of long term observational FU (average duration is 31 months with 8 months std. dev)

  2. IOP Control: Success was defined as ≥20% reduction in IOP, with "complete success" for IOP control without medications, "qualified success" with medications, and "failure" for <20% IOP reduction or IOP >21 mmHg.

    Time frame: From enrollment to the end of long term observational FU (average duration is 31 months with 8 months std. dev)

Secondary outcomes

  1. Hypotony, defined as intraocular pressure (IOP) < 5 mmHg, categorized as either transient or permanent.

    Time frame: From enrollment to the end of long term observational FU (average duration is 31 months with 8 months std. dev)

  2. Device migration or extrusion, monitored to assess mechanical stability of the implant.

    Time frame: From enrollment to the end of long term observational FU (average duration is 31 months with 8 months std. dev)

  3. Adverse Events/Severe Adverse Events: Device-related or non-device-related

    Time frame: From enrollment to the end of long term observational FU (average duration is 31 months with 8 months std. dev)

Study contacts

Contact information is provided by the study sponsor or research team.

Nikoloz Labauri, MD. FVRS

CONTACT

[email protected]

+995599003744

Sponsors and collaborators

Lead sponsor

Davinci LTD

Other

Registry information

Official study title

The Long-term Safety and Efficacy of a Modified Suprachoroidal Silicone Tube (SST) Shunt in Patients with Primary Open-angle Glaucoma (POAG) and Pseudo-exfoliative Glaucoma (PXG) Over an Extended Follow-up Period

Important dates

Study start
2024
Primary completion
2024
Study completion
2024
First posted
Nov 15, 2024
Registry last updated
Nov 15, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.