Skip to main content
OpenTrials
Completed

NCT Number: NCT03212924

Listening Effort in Cochlear Implant Users

Listening with a cochlear implant remains difficult and most listeners will report high levels of listening effort.The present study is a "pilot" aiming to evaluate listening effort for cochlear implant users. The listening effort is measured with pupillometry, by monitoring the variations of pupil size in response to different stimuli. The size of the pupil is known to increase with the listening effort. The listening effort is evaluated in two different situation: speech perception in quiet and speech perception in noise. The pupillometry measures will be compared for the two listening conditions. Moreover, the study will evaluate the relationship between objective (pupil dilatation) and subjective measures (auto evaluation) of listening effort, and between speech comprehension, cognitive abilities and listening effort.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–70 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Hôpital Pitié Salpêtrière - APHP

Paris, 75013, France

About this study

Nowadays, cochlear implants (CI) are successfully used to rehabilitate severe to profound sensorineural hearing loss. Most CI users can understand speech in quiet, but comprehension scores drop in the presence of background noise and in adverse conditions. Listening with a cochlear implant remains very demanding and most listeners report high levels of listening effort. The aim of current auditory prostheses and cochlear implants is not only restore speech understanding, but also to restore all the cognitive functions that are associated to a listening task (e.g., memory, executive functions, attention). Evaluating the listening effort is a new way to assess the efficiency of the hearing aids or cochlear implants. The listening effort indicates the amount of cognitive resources that are dedicated to a listening task; it evaluates also the cognitive resources remaining available for the other cognitive functions. The present study is a "pilot" aiming to evaluate listening effort for cochlear implant users. The listening effort is measured with pupillometry, i. e. by measuring the pupil dilatation in response to different stimuli. The size of the pupil is known to increase with the listening effort. The listening effort is evaluated in two different situation: speech perception in quiet and speech perception in noise. Speech comprehension is measured for the two listening conditions and cognitive functions are assessed by the MOCA (Montreal Cognitive Assessment). In addition, the subjects are asked to subjectively evaluate the amount of listening effort they used in each listening situation. The pupillometry measures will be compared for the two listening conditions. Moreover, the study will evaluate the relationship between objective (pupil dilatation) and subjective measures (self evaluation) of listening effort, and between speech comprehension, cognitive abilities and listening effort.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • informed consent
  • Native French speaker or fluent French speaker
  • Patient already fitted with one or two cochlear implants Oticon Medical
  • Can correctly identify at least 10 % of the words in monosyllabic Lafon lists in quiet
  • Normal or corrected to normal vision

Exclusion criteria

  • vulnerable patients (kids, pregnant women, persons under guardianship)
  • No Social security affiliation
  • blindness

Treatment and study plan

Pupillometry

Behavioral

Measure of pupil dilatation simultaneously to the evaluation of speech intelligibility. The variation of the pupil size is monitored during the presentation of speech stimuli in quiet and in the presence of a background noise.

Evaluation of speech comprehension in quiet

Behavioral

Three lists of 17 monosyllabic words (Lafon) are presented in quiet at 65 dB SPL. Listeners have to repeat what they understood. The results correspond to the percent of phonemes correctly identified.

Evaluation of speech comprehension in noise

Behavioral

Three lists of 17 monosyllabic words (Lafon) are presented in a wide band noise at 65 dB SPL with a SNR (signal to noise ratio) of +10 dB. Listeners have to repeat what they understood. The results correspond to the percent of phonemes correctly identified.

MOCA

Behavioral

The Montreal Cognitive Assessment (MoCA) is a screening instrument to detect cognitive dysfunction. It assesses different cognitive domains: attention and concentration, executive functions, memory, language, visuoconstructional skills, conceptual thinking, calculations, and orientation. The time to administer the MoCA is approximately 10 minutes. The total possible score is 30 points. The test suggests the existence of a cognitive impairment if the participant scores less than 26 points. The test is presented on a single sheet of paper.

Other names: Montreal Cognitive Assessment

auto evaluation of listening effort in quiet

Behavioral

The participant has to represent, on a continuous line, the amount of listening effort he used when listening to the monosyllabic words presented in quiet. A score from 0 (no listening effort) to 10 (effort maximum) is extracted from his response.

Other names: VAS (visual analog scale) in quiet

auto evaluation of listening effort in noise

Behavioral

The participant has to represent, on a continuous line, the amount of listening effort he used when listening to the monosyllabic words presented in the background noise. A score from 0 (no listening effort) to 10 (effort maximum) is extracted from his response.

Other names: VAS (visual analog scale) in noise

Primary outcomes

  1. Pupil dilatation (mm)

    Time frame: 1 hour

    The listening effort while listening to speech stimuli is estimated by measuring the pupil size relative to a baseline. Measures of pupil dilatation are compared between quiet and noisy conditions (+ 10 SNR: signal to noise ratio).

  2. Amplitude of peak of pupil dilatation

    Time frame: 1 hour

    The listening effort while listening to speech stimuli is estimated by measuring the pupil size relative to a baseline. The peak is defined as the point in time where the maximum of pupil dilatation occurs. The amplitude of the peak of dilatation is compared between quiet and noisy conditions (+ 10 SNR: signal to noise ratio).

  3. Latency of peak of pupil dilatation (ms)

    Time frame: 1 hour

    The listening effort while listening to speech stimuli is estimated by measuring the pupil size relative to a baseline. The peak is defined as the point in time where the maximum of pupil dilatation occurs. The latency of the peak of dilatation is compared between quiet and noisy conditions (+ 10 SNR: signal to noise ratio).

Secondary outcomes

  1. Speech intelligibility in quiet

    Time frame: 30 mins simultaneously to pupillometry measures

    percentage of phonemes correctly identify when the speech stimuli (monosyllabic words of Lafon) are presented in quiet at 65 dB SPL

  2. Speech intelligibility in noise

    Time frame: 30 mins simultaneously to pupillometry measures

    percentage of phonemes correctly identify when the speech stimuli (monosyllabic words of Lafon) are presented in a wide band noise at 65 dB SPL with a +10 dB SNR (signal to noise ratio)

  3. MOCA (Montreal Cognitive assessment)

    Time frame: 15 mins

    Score at the MOCA. The maximum score is 30. The test suggests the existence of a cognitive impairment if the score is lower than 26.

  4. VAS quiet

    Time frame: 1 min

    Auto evaluation of the listening effort in quiet with Visual Analog Scale. The participant has to indicate, on a continuous line, the listening effort used in the quiet condition. A score from 0 (no effort) to 10 (maximum effort) is extracted from the VAS.

  5. VAS noise

    Time frame: 1 min

    Auto evaluation of the listening effort in quiet with Visual Analog Scale. The participant has to indicate, on a continuous line, the listening effort used in the noise condition. A score from 0 (no effort) to 10 (maximum effort) is extracted from the VAS.

Sponsors and collaborators

Lead sponsor

Oticon Medical

Industry

Registry information

Official study title

Evaluation of Listening Effort With Pupillometry in Cochlear Implant Users

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
Jul 11, 2017
Registry last updated
Aug 22, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.