Skip to main content
OpenTrials
Completed

NCT Number: NCT01431027

Left Ventricular Torsional Hysteresis: A Global Parameter for Diastolic Function

Diastolic dysfunction refers to abnormal mechanical properties of the myocardium and includes abnormal LV diastolic distensibility, impaired filling and slow or delayed relaxation- regardless of whether the ejection fraction is normal or depressed and whether the patient is asymptomatic or symptomatic. Epidemiologic studies have demonstrated high prevalence of diastolic heart failure (DHF). The quality of life of these patients is impaired and the clinical outcomes are similar to those with heart failure with systolic dysfunction. Therefore diastolic dysfunction has significant adverse economic impact that is expected to grow further with time. Clinical characteristics alone may not be sufficient to diagnose diastolic dysfunction. A number of invasive and non-invasive parameters have been proposed to diagnose diastolic dysfunction. Most of the presently used non-invasive parameters have a number of limitations. High fidelity measurement of the left ventricular pressures is needed to accurately diagnose diastolic dysfunction. Obtaining it in routine clinical practice is impractical.

In this protocol the investigators have proposed a novel non-invasive parameter called 'Torsional Hysteresis' as a measure of diastolic function. This will be measured using non-invasive cardiac MRI technique. During left ventricular contraction and relaxation, myocardium deforms. During cardiac cycle the myocardium goes back to baseline state prior to beginning of each contraction. However the rate with which it returns to the baseline state is variable. Torsion indicates relative wringing motion of the ventricle around a left ventricular axis and is a global parameter of left ventricular deformation. The parameters have defined a new parameter called torsional hysteresis based on non invasive cardiac MRI assessment. The parameters have hypothesized that for diastolic dysfunction, the torsional hysteresis area is increased as compared to no diastolic dysfunction group.

Completed

Looking for future studies?

Notify Me

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

UAB Hospital, Birmingham, Alabama, United States

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Major inclusion criteria: Normal screening LV ejection fraction.

Exclusion criteria

  • Atrial fibrillation or other significant cardiac arrhythmia on ECG
  • Presence of pacemaker or defibrillator
  • Angioplasty or primary coronary intervention PCI/PTCA during index cardiac catheterization.
  • Patient is unable to undergo cardiac MRI due to contraindication to MRI (MRI incompatible metal prosthesis or implants or significant claustrophobia).
  • Patient taking phosphodiesterase 5 inhibitor (eg. sildenafil) will be excluded due to potential interaction with nitroglycerin.

Treatment and study plan

Primary outcomes

  1. To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function

    Time frame: one time at enrollment

    To show that torsional hysteresis relates to invasive hemodynamic measure of diastolic function: a) Exponential fall of pressure during isovolumic relaxation phase by the time constant of relaxation, tau and b) LV end diastolic pressure-volume relationship (EDPVR).

Secondary outcomes

  1. To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function

    Time frame: one time at enrollment

    To demonstrate that torsional hysteresis is a relatively load independent measure of global diastolic function by evaluating effects of nitroglycerin (NTG) on torsional hysteresis and correlating it to invasive hemodynamic measure of diastolic function including a) tau and b) EDPVR.

  2. To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction

    Time frame: one time at enrollment

    To evaluate the sensitivity and specificity of torsional hysteresis in diagnosing diastolic dysfunction (as defined by invasive hemodynamic parameters: tau, EDPVR) and compare it to echocardiographic tissue Doppler assessment in patients undergoing cardiac catheterization for suspected diastolic dysfunction

Sponsors and collaborators

Lead sponsor

University of Alabama at Birmingham

Other

Collaborators

  • National Heart, Lung, and Blood Institute (NHLBI)

Registry information

Important dates

Study start
2011
Primary completion
2015
Study completion
2015
First posted
Sep 9, 2011
Registry last updated
Aug 18, 2015

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.