Japan-Drug Eluting Stents Evaluation; a Randomized Trial

To evaluate the procedural, short and long term clinical outcomes of the TAXUS stent compared to Cypher stent in coronary arteries of ≥ 2.5 and ≤ 3.75 mm in the reference vessel diameter with a lesion of ≤ 46 mm (by visual observation) in routine clinical settings in Japan.

Completed

Looking for future studies?

Notify Me

Key information

Age range

20 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Aichi Medical University Hospital, Aichi, Japan

Loading trial locations.

About this study

In these days, meta-analyses have been conducted in large scale and small scale studies, but there has been no conclusion yet stating which one of the stents, either Cypher stent or TAXUS stent, is superior to the other. In specific disease condition such as in diabetic patients, it has been reported that Paclitaxel (TAXUS stent) is more suitable than Sirolimus (Cypher stent), due to the difference in the action mechanisms of the drugs. Since TAXUS stent was recently approved in Japan, we decided to conduct a randomized multi-center comparative study to compare Cypher stent and TAXUS stent regarding the clinical endpoint (target vessel failure for 8 months). The study is powered to show equivalence between the 2 stents in all patients, and to show superiority of the TAXUS stent in the diabetic patient population. In addition, for selected patients, quantitative coronary angiography, intravascular ultrasound, optical coherence tomography, and angioscopy are performed to examine the difference of the two stents more closely.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient is ≥ 20 years old
  • Patient suitable for percutaneous coronary intervention (PCI)
  • Patient with signed informed consent
  • Patient judged suitable to receive anti-platelet drugs (clopidogrel bisulfate or ticlopidine hydrochloride, etc.) in principle for at least 6 months after procedure, and ideally up to 12 months in patients who are not at high risk of bleeding, based on ACC/AHA guideline
  • Patient with up to 3 lesions (with ≥ 50% of stenosis) in the maximum of 2 targeted vessels to be treated at once
  • Patient with reference vessel diameter (RVD) of 2.5 mm to 3.75 mm by visual observation
  • Patient with length of each lesion of up to 46 mm by visual assessment
  • Patient eligible for implementation of drug eluting stent.

Exclusion criteria

  • Patient with any planned treatment in the targeted vessel with a drug eluting stent other than in this study
  • Patient with acute myocardial infarction (AMI) (including non-ST segment elevation MI) developed within 7 days before the procedure
  • Patient participating in a currently ongoing registry or clinical study, or receiving a treatment which may affect the endpoints of this study
  • Patient of childbearing potential with a positive pregnancy test within 14 days before the procedure, or lactating
  • Patient who has history of allergy against Sirolimus, Paclitaxel, polymers or stainless steel
  • Patient who has history of side-effect against anti-platelet drugs or anti-coagulation drugs
  • Patient with serious hepatic dysfunction
  • Patient with left ventriculogram ejection fraction of 35% or less
  • Patient with three target vessels in need of PCI treatment
  • Patient with serious renal dysfunction (serum creatinine value 2mg/dL or higher)
  • Patient currently receiving artificial dialysis
  • Patient with a malignant tumor (cancer) diagnosed within 5 years before the procedure
  • Patient who has received PCI treatment within the past one year
  • Patient with chronic total occlusion (CTO) or TIMI flow 2 or less
  • Patient with >50% stenosis in left main coronary artery
  • Patient with >50% stenosis in side branch ostial for which stenting in the side branch lesion is required (KBT for side branch is accepted)
  • Patient with in-stent restenosis in the target lesion implanted with a bare-metal or drug eluting stent
  • Patient who has target lesion in saphenous vein graft
  • Patient judged non-eligible by the physician in charge.

Treatment and study plan

Taxus stent

Device

Compared two kinds of stents:TAXUS stent, approved for commercialization in Japan(March 30th, 2007)

Cypher stent

Device

CYPHER stent, approved for commercialization in Japan(March 25, 2004)

Primary outcomes

  1. Target Vessel Failure (TVF) at 8 months post-procedure(assessed prior to routine angiography) in Overall study population

    Time frame: 8 months

Secondary outcomes

  1. Target Vessel Failure (TVF) at 8 months post-procedure (assessed prior to routine angiography) in diabetic group

    Time frame: 8 months

Sponsors and collaborators

Lead sponsor

Associations for Establishment of Evidence in Interventions

Other

Registry information

Official study title

A Japanese Prospective, Randomized, Multi-center Trial Comparing the TAXUS Stent and the CYPHER Stent in Patients With Coronary Artery Disease Eligible for PCI.

Acronym: J-DESsERT®

Important dates

Study start
2008
Primary completion
2013
First posted
Jul 2, 2008
Registry last updated
Nov 5, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.