Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06737809

IP-coated Revision Hip Implants

The primary aim of the clinical investigation is to demonstrate the efficacy of a silver-based antimicrobial coating on hip implants in the reduction of periprosthetic infections in revision hip arthroplasty due to periprosthetic infection.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Charité - Universitätsmedizin Berlin, Berlin, Germany

Loading trial locations.

About this study

The clinical investigation will include patients indicated for revision hip arthroplasty due to chronic periprosthetic infection. Subjects will either receive standard CE-marked revision hip implants or the newly developed IP (Infection prevention)- coated revision hip implants. The primary clinical benefit of the IP hip implant components remains the functional restoration of the hip joint and pain relief, as successfully shown for the uncoated predecessor devices, but additionally the IP coating is regarded ancillary to the intended purpose of the implant. Periprosthetic infections are one of the major complications in revision hip arthroplasty, leading to implant re-revision. A clinical investigation to evaluate additional measures to reduce this complication rate in revision total hip arthroplasty therefore has high clinical relevance.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients > 18 years
  • Patients indicated for unilateral cementless acetabular and hip stem revision due to chronic periprosthetic infection (according to EBJIS definition): single-stage or two-stage surgical procedure according to clinical standard at the clinical investigation site
  • According to the assessment of the clinical investigator, the subject is therapy compliant and able to attend the follow-up visits
  • ASA physical status I - III
  • Patient's signed written informed consent is available

Exclusion criteria

  • Simultaneous participation in another interventional clinical trial (drugs or medical devices studies)
  • The investigational implant components (femoral and/or acetabular) are not suitable for the patient anatomy or bone defect
  • Patients who require plate osteosynthesis at the implantation site
  • Patients with an already implanted silver-coated device
  • Patients with immunodeficiency, i.e. patients currently receiving immunosuppressive therapy or patients with severe immunodeficiency requiring drug therapy
  • Patients currently undergoing cancer treatment, e.g. chemotherapy or radiation therapy
  • Severe soft tissue defects that require local or free flap procedure
  • Periprosthetic joint infections with evidence of fungal infection
  • Antibiotic suppression therapy
  • BMI > 40 kg/m2
  • Pregnancy, breast-feeding, or women of childbearing potential and not taking adequate contraceptive precautions
  • Known or patient reported hypersensitivity to silver or titanium
  • Patients held in a custodial setting
  • Patients in a relationship of dependence on the sponsor, the clinic or the investigator
  • Patients with contraindication for the investigational and comparator devices:
  • in case of secondary diseases influencing the function of the joint implant
  • in case of severe osteoporosis or osteomalacia
  • in case of poor bone quality and osseous malformations, diseases in the area of the implant fixation, which may primarily or subsequently affect the stability of the joint replacement anchorage
  • in case of non-regenerative bone conditions with lack of proximal femoral bone support and failure of defect union when use of prosthesis heads with neck length XXL is indicated

Treatment and study plan

IP Plasmafit® Revision cup (and stem) system

Device

Revision total hip arthroplasty (THA) due to periprosthetic joint infection

Primary outcomes

  1. Occurrence of periprosthetic joint infections

    Time frame: 12 months

    Participants are monitored for 12 months after revision surgery. Every case of periprosthetic joint infection according to the definition of the EBJIS classification counts.

Secondary outcomes

  1. Change of functional outcome over follow-up period (Harris Hip Score (HHS))

    Time frame: 2 years post operative

    Harris-Hip-Score: The Harris Hip Score (HHS) is a clinical tool used to evaluate the function of the hip joint, particularly after hip surgery or in cases of hip disease.

    The HHS consists of 10 items divided into four categories:

    Pain (maximum 44 points) Function (maximum 47 points) Range of Motion (maximum 5 points) Deformity (maximum 4 points)

  2. Changes in quality of life

    Time frame: 2 years post operative

    Measure Description: EQ-5D-5L

    The EQ-5D-5L is a standardized instrument used to measure health outcomes. Developed by the EuroQol Group (EQ), it assesses five dimensions (5D) of health:

    Mobility Self-care Usual activities Pain/discomfort Anxiety/depression Each dimension has five levels (5L) of severity: no problems, slight problems, moderate problems, severe problems, and extreme problems

  3. Implant survival

    Time frame: 2 years post operative

    Measure Description: Kaplan-Meier implant survival Kaplan-Meier Analysis is a standard statistical method to describe the survival of human subjects or medical products over a defined time period. The revision-free survival rate is the performance indicator of the product under investigation and confirms the clinical outcome of the hip prosthesis. Information on survival of the implant will be collected until the last follow-up of the study patients took place.

  4. Radiographic assessment

    Time frame: 2 years post operative

    radiographic measurements to assess implant migration, signs of loosening and changes in the fixation area over time

  5. Occurrence of safety issues with the new device

    Time frame: 2 years post operative

    Adverse events, device failures and component revision will be monitored throughout the study to assess the safety

  6. Level of silver ion concentration

    Time frame: 12 months

    Laboratory analysis will be performed to monitor silver ion concentration in biospecimen.

  7. Changes in blood biomarkers for liver function

    Time frame: 12 months

    Participants will be monitored for their level of liver enzymes (ALT, AST, GGT)

  8. Changes in blood biomarker for kidney function

    Time frame: 12 months

    Participants will be monitored for their level of kidney marker (eGFR).

  9. Changes in blood biomarker for inflammation

    Time frame: 12 months

    Participants will be monitored for their level of inflammation marker CRP.

Study contacts

Contact information is provided by the study sponsor or research team.

Britta Wachter, Dr.

CONTACT

[email protected]

+49 746195

Lutz Dreyer, Dr.

CONTACT

[email protected]

+49 7461 95

Sponsors and collaborators

Lead sponsor

Aesculap AG

Industry

Registry information

Official study title

HIPrevision - A Randomized Multicenter Clinical Investigation of Antimicrobial IP-Coated Revision Hip Prostheses

Acronym: HIPrevision

Important dates

Study start
2025
Primary completion
2027
Study completion
2028
First posted
Dec 17, 2024
Registry last updated
Jan 12, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)