Department of Neurology
Baltimore, Maryland, 21287, United States
Location status: Recruiting
NCT Number: NCT03161067
The Bidirectional Cortical Neuroprosthetic System (BiCNS) consists of NeuroPort Microelectrode Array Systems and NeuroPort Electrodes (Sputtered Iridium Oxide Film), Patient Pedestals, the NeuroPort BioPotential Signal Processing System, and the CereStim C96 Programmable Stimulator. The goals of this early feasibility study consist of safety and efficacy evaluations of this device.
Interested in participating?
Request Info22 year–65 year
All sexes
Interventional
Not applicable
Baltimore, Maryland, 21287, United States
Location status: Recruiting
This proposed early feasibility, investigator-initiated study is led by Dr. Nathan E. Crone, M.D. at Johns Hopkins Medicine (JHM). The Bidirectional Cortical Neuroprosthetic System (BiCNS) consists of modified versions of 510(k) cleared NeuroPort Electrode Array Systems (Blackrock Microsystems, Inc., Salt Lake City, UT) as well as a neurostimulator module (CereStim R96) for long term neural recording and intracortical microstimulation (ICMS) of the brain. The BiCNS is termed bidirectional because it permits both the recording of information from the brain for controlling an end effector device, as well as enabling information regarding that end effector to be returned to the brain in the form of ICMS. "End effector" in this sense is used to mean a physical or virtual device designed to interact with its (physical or virtual) environment. Electrode arrays will be implanted in the brain in pairs, with a pair comprising a recording array and a stimulating array. A total of six NeuroPort arrays, consisting of three array pairs, will be implanted in each study participant. Each pair will consist of an array implanted in primary motor cortex (M1) for recording and an array implanted in primary sensory cortex (S1) for stimulation and/or recording; both arrays in each pair will be connected to a single percutaneous pedestal as an external interface. In each participant, two such array pairs will be implanted in the hand/arm area of M1 and S1 in the dominant brain hemisphere (e.g., the left hemisphere for a right-handed individual). A third pair will be implanted in the hand/arm area of M1 and S1 in non-dominant hemisphere (e.g. right hemisphere for a right handed-individual). The recording arrays implanted in M1 are the NeuroPort microelectrode arrays with platinum (Pt) tips (K070272), whereas the ICMS arrays implanted in S1 are NeuroPort microelectrode arrays with Sputtered Iridium-Oxide Film (SIROF) tips (K110010). The study has Investigational Device Exemption (IDE) approval from FDA to implant these devices for 52 weeks (plus/minus 2 weeks).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Participants must meet all inclusion criteria, verified by medical evaluation, psychological evaluation, and review of medical history. Inclusion criteria include:
Exclusion criteria
All interested participants will be reviewed for the presence of exclusion criteria by medical evaluation, review of medical history, self (or assistant) report and evaluation by a psychologist. Presence of any of the following criteria will exclude participants from eligibility to participate. In addition, the medical team has the right to withdraw the participant at any time if any of the exclusion criteria emerge and participants can withdraw at any time for any reason. Withdrawal details are outlined below exclusion criteria. Exclusion criteria include:
Surgical implantation
Other names: NeuroPort
Time frame: 52 weeks
This outcome will be considered successful if the device is not explanted during the 52-week period. Explantation of the device prior to the 52-week study period implies that the device is putting the subject at risk (e.g. through a serious infection at implantation site) and therefore must be removed.
Time frame: 52 weeks
One or more participants demonstrate successful control of an assistive device using the action research arm test (ARAT). The ARAT's is a 19 item measure divided into 4 sub-tests (grasp, grip, pinch, and gross arm movement). Performance on each item is rated on a 4-point ordinal scale ranging from:
Time frame: 52 weeks
Intracortical microstimulation will be delivered to participants through the BiCNS device. The effect of ICMS will be measured based on participants' verbal reporting of what the stimuli feel like (quality of percepts) and where they appear to be coming from (location of percepts).
Contact information is provided by the study sponsor or research team.
Francesco Tenore, PhD
CONTACT
Nathan E Crone, MD
CONTACT
Johns Hopkins University
Other
Acronym: BiCNS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03482310
Central Nervous System Diseases, Nervous System Diseases
Cleveland, Ohio, United States
View Trial DetailsNCT02354625
Central Nervous System Diseases, Nervous System Diseases
Miami, Florida, United States
View Trial DetailsNCT00656149
Central Nervous System Diseases, Nervous System Diseases
Edmonton, Alberta, Canada
View Trial DetailsNCT00385918
Behavior, Central Nervous System Diseases
Baltimore, Maryland, United States
View Trial Details