Skip to main content
OpenTrials
Completed

NCT Number: NCT05426772

Investigation of the Effect of Kinesiotape Applied With Exercise on Muscle Oxygenation With Moxy Muscle Oxygen Monitor

Kinesio taping (KT) is an elastic adhesive tape with physiological effects, often used in rehabilitation and sports medicine. KT, which can stay in the body for 3 to 5 days, exerts a pulling force on the skin thanks to its wave-like structure and elasticity, and increases the gap between the subcutaneous soft tissue and fascia with its lifting effect. In this way, it reduces the superficial pressure and causes an increase in lymph circulation. In addition, with the effect it creates on the muscles, it allows maximum contraction and relaxation of the muscle and creates positive effects on the deep lymphatics. Another effective approach to increase blood circulation is exercise. Exercise, which is known to have many benefits, has been shown to increase both systemic circulation and muscle blood flow. There are findings in the literature that KT can increase the effectiveness of exercise, but it has been stated that this issue is not clear and more studies are needed. In order to evaluate the effects of KT on increasing the effectiveness of exercise and on circulation, the oxygen saturation of the muscle in the application area can be measured. As a matter of fact, "Moxy muscle oxygen monitor" has been used in the literature, which measures regional oxygen saturation (SmO2) and total hemoglobin (THb) in capillaries under the muscle. The Moxy muscle oxygen monitor is a lightweight (42 g) and small (dimensions: 61 × 44 × 21 mm) device that measures regional blood flow and oxygenation by placing it on the skin non-invasively with near-infrared spectroscopy (NIRS). Its validity in measuring muscle oxygenation was vigorous or fairly good, and its reliability was found to be moderate to high in low-intensity exercises (SROC: r = 0.842-0.993, ICC: r = 0.773-0.992, p < .01). It is thought that the application of KT, which is known to increase lymphatic and venous circulation, together with exercise will increase the amount of oxygen in the muscles. To the best of our knowledge in the literature, no study has been found in which this effect of KT is presented objectively. For this reason, it is aimed to examine muscle oxygenation with the Moxy muscle oxygen monitor, which provides objective data on KT applied with exercise.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Bandırma Onyedi Eylül University Faculty of Health Sciences Department of Physiotherapy and Rehabilitation

Balıkesir, Bandırma, Turkey (Türkiye)

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Volunteering to participate in the study
  • Being between the ages of 18-40
  • Being sedentary (<600 MET-min/week according to the International Physical Activity Questionnaire Short Form)
  • BMI <30kg/cm2
  • Subcutaneous fat thickness <12mm

Exclusion criteria

  • Having an open wound or infection in the application area
  • Having a chronic illness
  • Being pregnant
  • Having a psychological disorder
  • Having a lower extremity injury in the last 6 months
  • Having had any surgical operation involving the lower extremity in the last 6 months

Treatment and study plan

Exercise and Kinesiotaping

Other

Exercise: Aerobic exercise will be performed on the treadmill for 20 minutes with a maximum heart rate of 55%-65% and a perceived exertion of less than 3. The Moxy muscle oxygen monitor will take measurements over the quadriceps femoris muscle at this time.

Kinesiotaping: After 3 days, the same participants will be called for kinesiotaping application. The application will be applied to the quadriceps femoris muscle with the facilitation technique by a physiotherapist who has a kinesio taping training certificate.

Primary outcomes

  1. Moxy Muscle Oxygen Monitor

    Time frame: Baseline

    The Moxy muscle oxygen monitor is a lightweight (42 g) and small (dimensions: 61 × 44 × 21 mm) device that measures regional blood flow and oxygenation by placing it on the skin non-invasively with near infrared spectroscopy (NIRS). The device, which has data collection and telemetric features, also allows O2 measurement in non-laboratory environments and field-based research. Compared to other NIRS devices, the Moxy muscle oxygen monitor has been shown to be a valid and reliable device for muscle oxygenation. Its validity in measuring muscle oxygenation was strong or very good, and its reliability was found to be moderate to high in low-intensity exercises (SROC: r = 0.842-0.993, ICC: r = 0.773-0.992, p < .01). It has been reported that as exercise intensity increases, its reliability changes inversely.

  2. Moxy Muscle Oxygen Monitor

    Time frame: fourth day

    The Moxy muscle oxygen monitor is a lightweight (42 g) and small (dimensions: 61 × 44 × 21 mm) device that measures regional blood flow and oxygenation by placing it on the skin non-invasively with near infrared spectroscopy (NIRS). The device, which has data collection and telemetric features, also allows O2 measurement in non-laboratory environments and field-based research. Compared to other NIRS devices, the Moxy muscle oxygen monitor has been shown to be a valid and reliable device for muscle oxygenation. Its validity in measuring muscle oxygenation was strong or very good, and its reliability was found to be moderate to high in low-intensity exercises (SROC: r = 0.842-0.993, ICC: r = 0.773-0.992, p < .01). It has been reported that as exercise intensity increases, its reliability changes inversely.

Secondary outcomes

  1. heart rate

    Time frame: Baseline

    heart rate will be evaluated with pulse oximetry

  2. heart rate

    Time frame: fourth day

    heart rate will be evaluated with pulse oximetry

Other outcomes

  1. respiratory frequency

    Time frame: Baseline

    respiratory frequency will be evaluated with pulse oximetry

  2. respiratory frequency

    Time frame: fourth day

    respiratory frequency will be evaluated with pulse oximetry

  3. O2 saturation

    Time frame: Baseline

    O2 saturation will be evaluated with pulse oximetry

  4. O2 saturation

    Time frame: fourth day

    O2 saturation will be evaluated with pulse oximetry

  5. blood pressure

    Time frame: Baseline

    blood pressure will be evaluated with sphygmomanometer. Systolic and diastolic pressures will be assessed.

  6. blood pressure

    Time frame: fourth day

    blood pressure will be evaluated with sphygmomanometer. Systolic and diastolic pressures will be assessed.

Sponsors and collaborators

Lead sponsor

Bandırma Onyedi Eylül University

Other

Registry information

Important dates

Study start
2021
Primary completion
2023
Study completion
2023
First posted
Jun 22, 2022
Registry last updated
Jun 4, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.