Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography

The long-term goal of this project is to utilize very high-speed optical coherence tomography (OCT) technology to guide surgical treatments of corneal diseases. OCT is well known for its exquisite resolution, but until recently it has not had sufficient speed to capture the shape of the cornea because of eye motion during OCT scanning. The development of Fourier-domain (FD) OCT technology has made the requisite speed possible.

The objective of this project is to develop methods for imaging the cornea with an FD-OCT system that will precisely measure corneal shape and use this information to guide surgery. Cataract surgery in patients with previous laser vision correction often leads to significant near- or far-sightedness, a problem that could be resolved by using a more accurate intraocular lens power selection formula based on the measurement of corneal refractive power with OCT.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Casey Eye Institute, Oregon Health & Science University

Portland, Oregon, 97239, United States

Location status: Recruiting

Location contact

Afshan Nanji, MD

SUB_INVESTIGATOR

David Huang, MD, PhD

PRINCIPAL_INVESTIGATOR

Denny Romfh, OD

CONTACT

[email protected]

503-494-4351

Ellen Davis, MD

SUB_INVESTIGATOR

Humberto Martinez, COT

CONTACT

[email protected]

503-494-7712

Richard Stutzman, MD

SUB_INVESTIGATOR

Seema Gupta, MD

SUB_INVESTIGATOR

Winston Chamberlain, MD, PhD

SUB_INVESTIGATOR

Yan Li, PhD

SUB_INVESTIGATOR

About this study

This study is about an imaging method called Optical Coherence Tomography (OCT) which provides detailed cross-sectional (layered) views of structures in the eye. The OCT system scans a beam of light across the eye to take a picture. OCT provides a more detailed image than other imaging methods of the eye such as ultrasound, CT scan (computed tomography) and MRI (magnetic resonance imaging). In addition, OCT imaging does not touch the eye. OCT is routinely used in imaging structures in the back of the eye (retina) and cornea. This study uses high-speed FDA approved OCT systems. The proposed research plan is a combination of clinical studies and software development to be performed synergistically. Clinical studies will provide OCT images for image processing software development and testing. The image processing software will provide automated measurement of anatomic parameters essential for clinical use.

Cataract extraction and IOL implantation is the most common eye surgery. The power of the IOL implant is calculated from 2 measurements: the axial eye length (AL) and keratometric power (K). The Holladay II formula also uses the external corneal diameter ("white-to-white" or WTW) and anterior chamber depth (ACD). These formulae work well (±0.5D) in normal eyes. However, these formulae can leads to biased and unpredictable refractive results in eyes that had refractive surgery procedures such as LASIK, PRK, and RK. With a large number of patients undergoing refractive surgery every year, the problem is becoming more severe.

The conventional IOL formulae fail because several inherent assumptions are no longer true in the eye that had refractive surgery. These assumptions are: 1) The corneal refractive power is uniform. 2) The anterior and posterior corneal power has a fixed relationship such that the overall corneal refractive power can be calculated from the anterior keratometry (or topography) using the keratometric index. 3) The position of IOL can be predicted by K with or without additional information such as WTW and ACD.

Relative to the posterior curvature, the anterior curvature becomes flatter after myopic correction and steeper after hyperopic correction with LASIK or PRK. To adapt the conventional IOL formulae to this situation, most surgeons use rigid contact lens over-refraction to calculate an "effective K." However, the accuracy of refraction in cataract patients is poor due to poor vision. Alternatively, one could use a historical method to calculate the effective K from pre-refractive surgery values. However, those measurements are often no longer available. If many years have lapsed, the historical value may no longer accurately reflect the current shape of the cornea.

The axial position of the IOL is determined by the positions of lens zonules and capsule which is in turn related to the corneal curvature (K) in the normal eye. A flatter cornea (lower K) is usually associated with a larger anterior segment, where the lens apparatus is located further back. A more complex model that also uses a separately measured white-to-white corneal diameter may be even more accurate. In post-refractive surgery eyes, however, K is altered and no longer has the normal relationship with the size of the eye. One way to get around this is to enter the pre-refractive surgery K. However, this historical information is not always available. We believe that a better solution would be use an entirely different approach that does not depend on the 3 above assumptions at all. Since OCT can separately measure the corneal anterior and posterior surfaces and AC and lens dimensions, we believe it has the potential of being the basis of a much better IOL calculation formula.

Previously we developed a method to measure both anterior and posterior corneal surface curvatures and obtain more accurate corneal power measurements than conventional keratometry, which only measures the anterior surface. This was the basis of an OCT-based intraocular lens (IOL) formula that showed better results than other formulas for post-myopic LASIK cataract surgery. However, this formula was only on par with the best regression-based formulas in eyes with previous hyperopic LASIK or radial keratectomy (RK), because IOL position prediction error and higher-order corneal aberration limited the accuracy of optical calculations in in these cases. We propose to improve IOL position prediction by using the long-range OCT that can image the entire anterior eye and accurately measure the lens equatorial position. We propose to more accurately determine corneal power in the presence of high aberration by developing ray tracing techniques based on ultrahigh-speed OCT mapping of corneal surfaces. Together, these new methods should improve IOL selection and refractive outcome for all types of eyes. In addition, we will develop a new OCT-based toric IOL formula that takes into account posterior corneal astigmatism, which is ignored in conventional keratometry.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The subjects will be patients seeking cataract surgery with implantation of monofocal IOLs (including toric IOLs) but not multifocal or accommodative IOLs.
  • Subjects will have had post-laser vision correction (LVC) such as previous LASIK, PRK, laser sub-epithelial keratectomy (LASEK), epi-LASIK (surface laser ablation under a microkeratome-created epithelial flap) or RK. The post-LVC group will be subdivided into those who have previous hyperopic LVC and those who have previous myopic LVC.

Exclusion criteria

  • Inability to give informed consent.
  • Inability to maintain stable fixation for OCT imaging.
  • Inability to commit to required visits to complete the study.
  • Eyes with concurrent cataract, retinal diseases, glaucoma, or other eye conditions that may limit the visual outcome after surgery.

Treatment and study plan

OCT measurements

Device

This study is about a new imaging method to study the front part of the eye. This imaging method is called Optical Coherence Tomography (OCT) which provides detailed cross-sectional (layered) views of structures in the eye. The OCT system scans a beam of light across the eye to take a picture. OCT provides a more detailed image than other imaging methods of the eye such as ultrasound, CT scan (computed tomography), and MRI (magnetic resonance imaging). In addition, OCT imaging does not touch the eye. OCT is routinely used in imaging structures in the back of the eye (retina) and cornea. This study uses high-speed FDA approved OCT systemsThe measurements from the OCT systems are used in selecting IOL power.

Other names: Manufacturer/Name OCT Technology 510(K), Optovue/RTVue-CAM Fourier-domain K071250, Bioptigen/Bioptigen Fourier-domain K063343, Zeiss/Visante Time-domain K051789

Primary outcomes

  1. IOL power prediction (baseline visit)

    Time frame: Study enrollment

    Subjects will be assessed at study enrollment, and a prediction of the most suitable IOL power will be made. Predicted IOL power will be measured in Diopters.

  2. IOL power prediction error (post-operative visit)

    Time frame: No later than 6-months following cataract surgery.

    Subjects will be assessed no later than 6-months following cataract surgery to assess accuracy of IOL power prediction at baseline visit. IOL power error will be measured in Diopters.

Study contacts

Contact information is provided by the study sponsor or research team.

Denny Romfh, OD

CONTACT

[email protected]

503-494-4351

Humberto Martinez, COT

CONTACT

[email protected]

503-494-7712

Sponsors and collaborators

Lead sponsor

Oregon Health and Science University

Other

Collaborators

  • National Eye Institute (NEI)

Registry information

Official study title

Guiding the Treatment of Anterior Eye Diseases With Optical Coherence Tomography

Acronym: OCT IOL

Important dates

Study start
2011
Primary completion
2026
Study completion
2026
First posted
Sep 19, 2007
Registry last updated
Feb 12, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.