Sana'a university
Sanaa, Yemen
NCT Number: NCT07300371
This study aimed to evaluate the amount of force decay in pigmented and transparent elastomeric power chains. The principal investigator measured the amount of force decay at 7 intervals using a calibrated Dentaurum force gauge. This study also assessed the associated variables that accelerate the force loss, such as brushing frequency, beverage consumption,mastication, Khat chewing, oral , and tooth movement, . The study outcomes provide evidence-based guidance for selecting elastomeric power chains in routine orthodontic practice.
Looking for future studies?
Notify Me12 year–30 year
All sexes
Interventional
Not applicable
Sanaa, Yemen
The study was a split-mouth randomized clinical trial. Four colors (pink, blue, black, and grey) and transparent elastomeric power chains from 3 different companies (American Orthodontic, SIA, and Matt) were evaluated. A total of 96 participants were recruited, and 192 elastomeric power chains were stretched between the canine bracket hook and the molar band hook throughout the study period. The delivered force of elastomeric power chains was assessed and compared among each other using a calibrated Dentarum force gauge over 6-week intervals (baseline, 24 hours, first week, second week, third week, fourth week, fifth week, and sixth week). To further investigate factors influencing force decay (FD), data on tooth movement, mastication side, beverage consumption, brushing frequency, oral hygiene status, and khat chewing were collected using a structured questionnaire to assess their potential impact.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Matt gray elastomeric power chains is Orthodontic auxiliary/ elastomeric power chains.
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Orthodontic Auxiliary force generated system
Time frame: Baseline and weekly for 6 weeks.
Measurement of the amount of force decay (in grams) for each elastomeric power chain sample at baseline and at 7 time intervals over 6 weeks using a digital force gauge.
Time frame: At 6 weeks
Correlation analysis between force decay values (in grams) and the associated variables collected through a structured questionnaire.
Sana'a University
Other
Intra-oral Evaluation of Force Decay of Pigmented and Transparent Elastomeric Power Chains: A Randomized Clinical Trail.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07566533
Clear Aligner Therapy, Malocclusion
Lahore, Punjab Province, Pakistan
View Trial DetailsNCT05361616
Malocclusion, Orthodontic Treatment
Edmonton, Alberta, Canada
View Trial DetailsNCT07532044
Malocclusion, Orthodontic Pain (D013850)
Islamabad, Federal, Pakistan
View Trial DetailsNCT06858670
Anodontia, Bites and Stings
Hanoi, Vietnam
View Trial Details