Massachusetts General Hospital
Boston, Massachusetts, 02114, United States
NCT Number: NCT01766102
A breast biopsy in the operating room may be needed in up to 15% of patients with an abnormality on mammogram. When an abnormality is present but there is no palpable mass, the abnormality must be localized with a wire before going to the operating room. This technique is also used when a breast cancer is present but there is no mass, in order to perform a targeted lumpectomy. Once the abnormality is surgically removed, the specimen with the wire is taken to the breast imaging department for a specimen x-ray to ensure that the targeted abnormality is present within the specimen. If the abnormality is close to the edge of the specimen, additional tissue is often removed.
A newer method for evaluating the specimen is to perform imaging in the operating room. Portable digital mammography units are available for this purpose. The Biovision digital specimen mammography system is FDA-approved and currently in use in over 200 centers in the United States. Several studies have shown that intra-operative digital mammography is as accurate as standard specimen mammography and takes less time to perform. It may also decrease the chance of having to go back to the operating room to take more breast tissue after lumpectomy because of cancer cells near teh margin(s) of the specimen on final pathology. Having to go back to the operating room to take more tissue is called a re-excision.
The purpose of this study is to compare standard specimen mammography to intra-operative specimen mammography to quantify potential operating room time savings and to determine if the use of intra-operative specimen mammography decreases re-excision rates. We aim to see if intra-operative specimen mammography is more efficient and if it decreases re-excision rates.
Looking for future studies?
Notify Me18 year and older
Female
Interventional
Phase 4
Boston, Massachusetts, 02114, United States
Before the research starts patients will undergo some screening procedures to determine if patients are eligible to participate. This includes a medical history and an assessment of the patient's breast abnormality by mammogram and/or ultrasound and/or breast MRI. Patients will not need to undergo any extra procedures apart from those needed by the patient's surgeon to plan the patient's breast surgery. If the screening process shows that a patient is eligible to participate in this research study, the patient will be enrolled and the study will proceed on the day of surgery. If a patient does not meet the eligibility criteria the patient will not be able to participate in this research study.
Patients will be assigned to one of two arms of this study on the day of your surgery. Because no one knows which of the breast specimen imaging options is best, patients will be "randomized" into one of the study groups: the Standard Specimen Mammography arm or, the Intra-operative Specimen Mammography arm. Randomization means that the patient is put into a group by chance. It is like flipping a coin. Neither the patient nor the surgeon will choose what group the patient will be in.
If the patient is in the Standard Specimen Mammography arm, the patient's breast specimen (biopsy or lumpectomy) will be taken to the Breast Imaging department for a mammogram, which is the way breast specimens are typically imaged. If the patient is in the Intra-Operative Specimen Mammography arm, the patient's breast specimen will be imaged right in the operating room at the time of the surgery. The patient's images will also be linked to the Breast Imaging department, so the radiologist can confirm the surgeon's findings.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The patient's breast specimen will be imaged in the operating room in an intra-operative imaging device - Biovision SN #30042
Other names: Biovision SN # 30042
There is not an added device associated with this arm.
Time frame: At the time of the procedure (approximately 1 week after randomization)
To compare the overall operative time savings using intra-operative digital mammography compared with standard specimen mammography.
Time frame: 2 years
Assessment of radiographic findings and pathologic findings to determine sensitivity, specificity, positive predictive value, and negative predictive values of intra-operative digital specimen mammography (ISM) and standard specimen mammography for determining margin status.
Massachusetts General Hospital
Other
A Comparison of Intra-Operative Digital Specimen Mammography to Standard Specimen Mammography
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT05754658
Breast Cancer, Breast Diseases
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT07040514
Breast Cancer, Breast Diseases
Lebanon, New Hampshire, United States
View Trial DetailsNCT06604858
Breast Cancer, Breast Diseases
A Coruña, Spain
View Trial Details