Department of Environmental Health, School of Public Health, Fudan University
Shanghai, Shanghai Municipality, 200032, China
NCT Number: NCT02239744
This study aimed to evaluate whether a short-term indoor air purifier intervention improves cardiopulmonary health based on a randomized double-blind crossover trial
Looking for future studies?
Notify Me18 year–26 year
All sexes
Interventional
Not applicable
Shanghai, Shanghai Municipality, 200032, China
We conducted a randomized double-blind crossover trial among 35 healthy college students in Shanghai, China in 2014. These students lived in dormitories that were randomized into two groups and alternated the use of true or sham air purifiers for 48 hours with a 2-week wash-out interval.All participants and research staff were blinded to the group assignment. We requested all participants to stay in their dormitory room with the windows/doors closed throughout each 48-hour intervention period. We delivered foods and drinks to each room during the intervention period. All interventions started at 8 a.m. to avoid issues related to diurnal variation. We evaluated health endpoints and drew blood immediately after the completion of each 48-hour intervention. We measured 14 circulating biomarkers of inflammation, coagulation and vasoconstriction, lung function, blood pressure (BP), and fractional exhaled nitric oxide (FeNO).
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The 10 dormitory rooms were randomized into two groups of 5 rooms each. One group used an air purifier placed in the center of the room for 48 hours corresponding to one weekend, followed by a 2-week washout period, and another 48 hours of using a sham air purifier under the same conditions. The other group simply reversed the order in which the real and sham air purifiers were used. All rooms used the same qualified air purifiers (model FAP04, 3M Filtrete), with the only difference being removal of the filter gauze in the sham purifiers. The air pollution auto-sensing feature of air purifiers was disabled in both groups. All participants and research staff were blinded to the group assignment. We requested all participants to stay in their dormitory room with the windows/doors closed throughout each 48-hour intervention period.
Other names: Air filtration
Time frame: Blood samples were drawn within one hour after the intervention, and lab analysis was completed in the next 10 days
Peripheral blood samples (5 ml) were drawn by a nurse, separated into serum and plasma, and stored at -80 ℃ within 30 minutes. We measured the levels of 14 circulating biomarkers: (1) 8 biomarkers of inflammation, including C-reactive protein (CRP), fibrinogen, P-selection, monocyte chemoattractant protein-1 (MCP-1), interleukin-1b, interleukin-6, tumor necrosis factor-α (TNF-α) and myeloperoxidase; (2) 4 biomarkers of coagulation, including soluble CD40 ligand (sCD40L), plasminogen activator inhibitor-1, tissue plasminogen activator and D-Dimer; and (3) 2 biomarkers of vasoconstriction, including endothelin-1 and angiotensin-converting enzyme.
Time frame: Within 1 hour after the end of the two-day intervention
A respiratory physician measured forced vital capacity, forced expiratory volume in 1 second and peak expiratory flow of each participant using the JAEGER Masterlab equipment (Würzburg, Germany) that meets the American Thoracic Society criteria. The volume signal was calibrated at least once on a testing day with a 3.0 L syringe connected to the pneumotachograph in accordance with the manufacturers' recommendations. We instructed participants to perform at least three forced expiratory lung function maneuvers in order to obtain a minimum of two acceptable and reproducible values, and we recorded the best results.
Time frame: Within one hour after the 2-day intervention
After sitting in a quiet room for at least 5 min, participants had their left upper arm BP measured by trained technicians using a mercury sphygmomanometer at least three times with 2-min minimum intervals between measurements. The second and third sets of readings were averaged to obtain systolic BP and diastolic BP. Pulse pressure was calculated as the difference between systolic BP and diastolic BP. If the differences among the three measurements were bigger than 5 mmHg, a new round of measurements were arranged.
Time frame: within 1 hour after the two-day intervention
FeNO is an established biomarker of respiratory inflammation, and has been widely used in epidemiological studies because of its high sensitivity, specificity and non-invasive nature. We measured FeNO levels using a portable NIOX MINO machine (Aerocrine AB, Solna, Sweden) according to standardized procedures by the American Thoracic Society and the European Respiratory Society.
Fudan University
Other
Cardiopulmonary Benefits of Reducing Indoor Particles of Outdoor Origin: a Randomized Double-blind Crossover Trial of Air Purifiers
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03255187
Blood Pressure, Cardiovascular Diseases
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT02339415
Blood-Borne Infections, Cardiovascular Diseases
Minneapolis, Minnesota, United States
View Trial DetailsNCT02658383
Blood Pressure, Glycated Hemoglobin (HbA1c)
La Esperanza, Intibucá Department, Honduras
View Trial DetailsNCT04994418
Blood Pressure, Inflammation
Newark, Delaware, United States
View Trial Details