Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT02789956

Internal vs. External Connection in Screw-retained Multi-units Bridges With Cad/Cam Milled Co/Cr Framework (ISUS-Atlantis)

The aim of this study is to evaluate:

Primary objective The primary objective of the present study is to evaluate the marginal bone level changes when partially edentulous patients, treated with implants, received a multiunits screw retained fixed dental prosthesis with a Co/Cr milled framework with an Internal or External connection.

Secondary objective

1. Overall survival rate. 2. Soft tissue status by assessment of bleeding on probing (BoP) and probing pocket depth (PPD) at baseline and after 1,3,5 years. 3. Prosthetic survival rates including screw or abutment loosening, framework or veneer fractures.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year–90 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Studiotoia Srl

Busto Arsizio, Varese, 21052, Italy

About this study

A randomized pilot study is designed to determine marginal bone changes between patients treated with a milled framework in Co/Cr if the connection is Internal or External for the rehabilitation of a partially edentulous area with a multiunit screw retained bridge. The investigation will be performed in one clinical centre affiliated to the Department of oral and maxillofacial surgery, Faculty of Odontology, Malmö University . In this center the clinician and the examiner will be the same person.

Following a screening examination, subjects who will meet the inclusion criteria, will sign the Informed Consent and will be enrolled in the study. The period of patient enrollment will begin on October 1st 2015 and ends September 31st 2016.

The patients will be randomized with a method based on the use of sealed opaque envelopes. The cases will be assigned to two different treatment groups:

Group A- Co/Cr milled framework with internal connection (Test) Group B- Co/Cr milled framework with external connection (Control)

-Pre-treatment Patient data, medical history, clinical and radiographic examination will be recorded for each patient. Clinical photographs will be taken in frontal, occlusal and lateral projections Periodontal, endodontic and open caries lesions will be treated prior to implant installation. All patients will receive careful oral hygiene instructions and training in self-performed plaque control measure.

Orthopantomogram at constant magnification and CT scan computed exams will be carried out.

Plaster models and diagnostic wax-up will be carried out.

-First Surgical Phase (Implant Installation) The patient will receive antibiotic prophylaxis (Amoxicillin 1gr) one hour prior to surgery and after the completion of implant installation until suture removal with 1gr three times a day. (If the patient is allergic to amoxicillin the examiner prescribes antibiotics at his own discretion at the same posology).

The surgical treatment will be performed under local anaesthesia. In case of remaining teeth, they will be extracted with conventional technique before implants' placement.

Implants will be placed according to the guidelines described in the Astra Tech Osseospeed EV® manual "Surgical procedures", using a two-stage protocol.

Implant spinning during the positioning of the cover screw will be registered as positive, if present, or negative.

The operation will be finalized by a careful adaption of the flaps by means of an accurate suture in order to obtain a full periosteal coverage.

Intraoral clinical photographs before, during and after surgery will be taken. -Post-operative care The patients will be instructed to rinse with chlorhexidine 0.12% mouthrinse and will be told to rinse with the antiseptic solution three times a day for 2 weeks. The patients will be advised to take NSAIDs for pain relief at their own discretion.

Liquid and semisolid food will be prescribed for the first post-operative week, after which the sutures will be removed.

Two weeks after the operation the denture will be properly relined until the second stage surgery.

Patients will be controlled at third and sixth weeks.

-Prosthetic procedures After eight weeks (+ 2) of implants healing a second stage surgery will be applied and Healing Abutment will be performed groups A while a Uni Abutment 33° connection procedure will be performed. In group B.

Impression with a customized spoon and Impregum material will be taken after one week from the second surgery and prosthetic procedure will be performed according to the Atlantis-Isus Dentsply Astra-tech prosthetic manual recommendations.

After 6 weeks (+ 2) from impression the definitive fixed dental prostheses screw retained multiunits bridge will be applied.

The prosthesis will be made to accomplish the normal hygienic procedures. All prosthetic procedures will be made in accordance to the Astra Tech procedures & products manuals.

The length of bridge cantilevers will be duly calculated to minimize implant overloading according to the Atlantis-Isus recommendations for both group.

-Post-prosthetic measurements Clinical measurements Clinical examinations will be performed immediately following the installation of the definitive prosthesis (Baseline-Loading) and after 1, 3, and 5 years. In particular, plaque and soft-tissue inflammation will be registered. Clinical photographs will be taken at each interval point.

Plaque: the presence of plaque will be scored at each implant site as well as at level of the remaining teeth on four surfaces (buccal, lingual/palatal, mesial, distal). The mean percentage of plaque harboring surfaces will be calculated using the case as the unit.

Soft-tissue inflammation: the presence of soft-tissue inflammation (bleeding on probing) will be assessed on buccal, lingual/palatal, mesial, distal aspects of each implant. The mean percentage of inflamed sites will be calculated using the case as the unit.

  • Radiographic measurements

Peri-apical radiographs will be taken at prosthesis insertion (Baseline) and after 1, 3, and 5 years.

The radiographs will be taken with an X-ray apparatus supplied with a long cone by the examiner each visiting time. Rinn centrators will be used to ensure reproducibility in the measurement of marginal bone level change.

The radiographic images will be analysed at the Department of Radiology of Sahlgrenska Academy, Gothenburg University by experienced radiologists who will be otherwise not involved in the study.

  • STATISTICAL ANALYSIS

Results will be presented by appropriate descriptive and inferential statistic. Demographic and other baseline characteristics will be presented by means of descriptive statistics. Continuous variables will be presented by means of number of observations (N), minimum (min), median, maximum (max), mean and standard deviation (std). Discrete variables will be presented by frequency and percentage.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age > 18 years.
  • Willingness to comply with all study requirements and to sign the IC.
  • Systemic health.
  • Compliance with good oral hygiene.
  • Patients with at least 2 teeth to replace in any side of the jaws.

Exclusion criteria

  • Patients treated with implant with bone defects associated with severe knife-edge ridges.
  • Patients treated with bone defects resulting from tumor resection.
  • Tobacco abuse (> 10 cigarettes/day).
  • Severe renal and liver disease.
  • History of radiotherapy in the head and neck region.
  • Chemotherapy for treatment of malignant tumors at the time of the surgical procedure.
  • Uncontrolled diabetes.
  • Active periodontal disease involving the residual opposite dentition.
  • Mucosal disease, such as lichen planus, in the areas to be treated.
  • Poor oral hygiene.
  • Non-compliant patients.
  • Situations judged inconvenient(by the investigator) for the surgical treatment.

Treatment and study plan

Internal vs. external cad cam co/cr framework

Device

Other names: Astratech EV system, Dentsply HI

Primary outcomes

  1. Marginal bone resorption in millimeter from the implant to the bone crest.

    Time frame: 1 year

  2. Marginal bone resorption in millimeter from the implant to the bone crest.

    Time frame: 3 year

  3. Marginal bone resorption in millimeter from the implant to the bone crest.

    Time frame: 5 year

Secondary outcomes

  1. Fracture of the prosthetic components

    Time frame: 1 year

  2. Fracture of the prosthetic components

    Time frame: 3 year

  3. Fracture of the prosthetic components

    Time frame: 5 year

Sponsors and collaborators

Lead sponsor

Institute Franci

Other

Registry information

Official study title

Clinical Outcomes of Implant- Versus Abutment-level Connection in Screw-retained Fixed Dental Prostheses

Important dates

Study start
2016
Primary completion
2024
Study completion
2025
First posted
Jun 3, 2016
Registry last updated
Feb 5, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.