Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT04818645

Insertable Cardiac Monitor for Primary Atrial Fibrillation Detection in High-Risk Heart Failure Patients

Patients with heart failure (HF) represent a large population of patients who are at high risk for complications related to undiagnosed atrial fibrillation (AF). However, currently there are limited modalities for early AF detection and subsequent stroke prevention in this high-risk population. An implantable cardiac monitor (ICM) is inserted subcutaneously and can provide long term arrhythmia information via remote monitoring.

The ASSERT-AF study seeks to accurately define the burden of AF and other arrhythmias in high-risk HF patients using an ASSERT ICM.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of Rochester Medical Center

Rochester, New York, 14642, United States

About this study

Over 6 million people in the United States suffer from heart failure (HF). By the year 2030 the prevalence of HF is expected to exceed 8 million people. Heart failure accounts for 1 million hospital admissions each year, costing our economy in excess of $30 billion dollars per year. Mortality in patients with HF remains high, and nearly half of all patients diagnosed with HF will die within 5 years. More than half of all patients admitted with HF decompensation have preserved left ventricular systolic function. Patients with HF and mildly reduced or preserved left ventricular systolic function are at high risk for developing atrial fibrillation (AF), the occurrence of which often contributes to HF decompensation and increases morbidity and all-cause mortality. Similarly, patients with AF are at high risk for developing HF due to loss of atrio-ventricular synchrony and rapid uncontrolled ventricular rates. Detection of AF can be challenging and may go undiagnosed in asymptomatic or minimally symptomatic patients through conventional monitoring methods. Patients with HF represent a large population who are at risk for complications related to undiagnosed AF. AF increases the risk of stroke five-fold and the risk of death nearly two-fold. Moreover, strokes related to AF are twice as likely to be fatal or severely disabling compared to strokes due to other causes, such as ischemic small vessel disease or atheromatous large vessel disease. Cardiac implantable electronic devices (CIEDs), can be used for the early detection of AF in asymptomatic or mildly symptomatic patients with HF. However, current guidelines provide an indication for prophylactic implantable cardioverter defibrillator (ICD) only in HF patients with left ventricular ejection fraction (LVEF) ≤ 35%, whereas there are limited data for device-based detection of AF in HF patients with more preserved LVEF.

Implantable cardiac monitors (ICM) are devices that can be injected into the subcutaneous tissue and can provide automatic electrocardiographic recordings of asymptomatic arrhythmias as well as patient triggered electrocardiographic recordings of symptomatic episodes during long term follow-up. Implantable cardiac monitors are be paired with remote monitoring systems, capable of rapid remote review of electrograms. Accordingly, we hypothesize that a management strategy that incorporates ICM implantation in patients with HF and LVEF >35% will result in a significantly higher rate of AF detection leading to arrhythmia related interventions compared to conventional monitoring and follow-up in patients with HF.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male and female patients more than 18 years of age (no upper age limit)
  • HF exacerbation requiring initiation or augmentation of decongestive therapy in a hospital setting (hospitalization or emergency department visit) during the past 24 calendar months prior to consent date OR current treatment with loop-diuretics (furosemide, bumetanide, or torsemide).
  • LVEF > 35% on a cardiac imaging study (echocardiogram, nuclear imaging, cardiac magnetic resonance imaging) performed during the past 24 calendar months prior to consent date
  • One or more FDA-approved indications for an Abbott ICM (unexplained symptoms such as: dizziness, palpitations, chest pain, syncope, and shortness of breath, as well as patients who are at risk for cardiac arrhythmias).
  • Willing to undergo an Abbott ICM implant and agree to remote ICM monitoring.

Exclusion criteria

  • Existing implantable cardioverter defibrillator (ICD), biventricular ICD, implantable cardiac monitor or pacemaker.
  • Known or documented history AF or atrial flutter any time in past.
  • Has had a heart transplant
  • Participation in other clinical trials (observational registries are allowed with approval from the Coordination Center)
  • Unable or unwilling to cooperate with the protocol
  • Unable or unwilling to sign the consent for participation

Treatment and study plan

ASSERT Insertable Cardiac Monitor

Device

Subjects will be subcutaneously implanted with an Abbott ASSERT ICM with the device implant procedure per standard of care and current labelling. Data related to subjects' arrhythmias, via the Merlin.net Patient CareNetwork will be transmitted on a monthly basis to the treating physician and subsequently to the study coordination and database center (CCRC) at the University of Rochester. Data on the frequency/types of symptomatic (patient triggered) versus ICM detected (asymptomatic) arrhythmic events will be collected and adjudicated. Clinical data on medication, device interventions, cardiovascular events will be collected at follow-up visits.

Conventional Management and monitoring

Other

Subjects randomized to the conventional management arm of the trial will undergo arrhythmia monitoring based on clinical indications and per standard available modalities including periodic electrocardiograms (ECG), Holter and/or event monitoring.

Primary outcomes

  1. Median Time to first detection of AF lasting > 5 minutes

    Time frame: 24 months

    Defined as ICM detected AF in the intervention (implantable cardiac monitor) arm or captured by clinical symptoms and documented by ECG or Holter in the conventional arm.

Secondary outcomes

  1. Time to initiation of guideline directed anti-arrhythmic and HF interventions

    Time frame: 24 months

    Interventions such AF ablation, initiation of antiarrhythmic, anticoagulation, beta-blocker therapy and others.

  2. Number cardiovascular hospitalizations or death

    Time frame: 24 months

    Total number of cardiovascular hospitalizations or death in each arm.

  3. Compare healthcare utilization using Abbott ICM vs. non-ICM monitoring.

    Time frame: 24 months

    Including emergency department visits, unplanned office visits, cardiovascular hospitalization or death

  4. Mean quality of life measured using the Kansas City Cardiomyopathy Questionnaire (KCCQ)

    Time frame: 24 months

    All KCCQ scores are scaled from 0 to 100 and frequently summarized in 25-point ranges, where scores represent health status as follows: 0 to 24: very poor to poor; 25 to 49: poor to fair; 50 to 74: fair to good; and 75 to 100: good to excellent.

  5. Mean percentage of time spent in atrial fibrillation (AF Burden)

    Time frame: 24 months

    AF burden, defined as average percentage of time spent in AF (i.e. amount of time spent in AF divided by the total amount of time a patient was monitored). AF burden will be quantified only in the intervention arm.

  6. Time to detection of composite of arrhythmic events endpoint

    Time frame: 24 months

    Arrhythmic events consisting of AF, sustained ventricular tachycardia, and high-risk bradyarrhythmias (high degree AV block or sinus pause > 5 seconds), whichever occurs first.

Other outcomes

  1. Compare the effect of patient-triggered transmissions on the time to Abbott ICM detection of arrhythmic events triggered by symptomatic recordings versus automatically detected arrhythmic event recordings.

    Time frame: 24 months

  2. Evaluate the rate of actionable interventions following symptom triggered event versus the rate of actionable interventions associated with automatic detected arrhythmic events.

    Time frame: 24 months

    Including initiation of oral anticoagulation, guideline directed medical therapy, device and procedural interventions.

  3. Correlate ICM interrogation data relating to heart sounds, body posture, activity, sleep detection and heart rate variability, with the risk of new heart failure events.

    Time frame: 24 months

    Such as hospitalizations, ED visits, unplanned office visits, out patients treatment with intravenous diuretic.

Sponsors and collaborators

Lead sponsor

University of Rochester

Other

Collaborators

  • Abbott

Registry information

Official study title

Insertable Cardiac Monitor for Primary Atrial Fibrillation Detection in High-Risk Heart Failure Patients (ASSERT-AF)

Acronym: ASSERT-AF

Important dates

Study start
2023
Primary completion
2028
Study completion
2028
First posted
Mar 26, 2021
Registry last updated
Mar 23, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.