Skip to main content
OpenTrials
Enrolling by Invitation

NCT Number: NCT07454005

Innovative Probe With Laser on Radial Artery Puncture and Catheterisation in Paediatric

During prolonged major surgical procedures in paediatric, significant fluctuations in vital signs occur. To ensure real-time, precise monitoring of haemodynamic parameters such as blood pressure and heart rate for maintaining intraoperative safety, radial artery catheterisation remains the most conventional monitoring method for such operations. Ultrasound-guided radial artery puncture has gained increasing favour among clinicians over traditional palpation and blind techniques due to its visualisation and real-time advantages, with its benefits becoming increasingly evident. Nevertheless, this technique still carries a relatively high failure rate. This study proposes the 'laser-assisted T-shaped three-dimensional ultrasound localisation technique' for paediatric radial artery puncture and catheterisation. This aims to enhance puncture success rates, reduce the need for repeated attempts, lower complication incidence, safeguard the patient's life during surgery, and improve the quality of medical services.

Enrolling by Invitation

Interested in participating?

Request Info

Key information

Age range

1 day–24 month

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Zhiwen Li

Changchun, Jilin, 130021, China

About this study

Following induction of anaesthesia in the paediatric patient, position one arm in slight abduction with a thin rolled bandage placed beneath the wrist to maintain mild dorsal extension. Disinfect the radial artery puncture site with povidone-iodine solution and drape the area. Select the appropriate ultrasound system and probe according to the assigned group (T-shape ultrasound guidance group or out-of-plane ultrasound guidance group).

T-shaped probe ultrasound guidance Group:

Fit the 3D-printed housing, which contains a laser emitter, onto the T-shaped ultrasound probe. The laser emitter is positioned directly above the mark on the short-axis plane of the T-shaped ultrasound probe. Instruct the assistant to apply an appropriate amount of coupling gel evenly to the ultrasound probe. Working in conjunction with the assistant, the operator should cover the entire assembly-comprising the 3D-printed, three-axis adjustable support arm and the ultrasound probe-with a sterile sleeve, expel any air from between the probe and the sleeve, and apply sterile coupling gel evenly to the outer surface of the sleeve where it will come into contact with the child's skin to complete the preparation of the equipment. To begin positioning, the operator uses the support arm to gently place the T-shaped ultrasound probe 0.5 cm below the child's wrist crease, with the short axis at the distal end and the long axis at the proximal end. The support arm and rotation axis are adjusted so that the midline of the short-axis ultrasound image passes through the centre of the radial artery's cross-section. Subsequently, with the short axis as the centre, the long axis is swivelled in a fan-shaped pattern from side to side to achieve optimal visualisation of the radial artery in the long-axis ultrasound image. At this point, the laser beam is directed towards the superficial projection of the target radial artery beneath the ultrasound probe. Once the support arm has been adjusted to ensure the probe rests stably against the skin surface, a stable, fully visualised ultrasound-guided procedure is established that can be performed by a single operator using both hands. The operator holds the ultrasound probe steady with their left hand, whilst holding a 24G arterial puncture cannula in their right hand, ensuring the laser fully covers the needle shaft and inserting the needle at an angle of approximately 30° to the skin (the insertion point is 0.5 cm from the ultrasound probe). Once the needle tip has entered the subcutaneous tissue, if deviation is observed on the short-axis ultrasound image, the angle of insertion may be adjusted, with the number of adjustments recorded. The needle should penetrate the anterior wall directly above the radial artery; whilst the right hand maintains the position of the cannula, the left hand slides the probe towards the proximal end and, using the short-axis image, determines the position of the needle tip prior to cannula insertion according to the 'dynamic needle tip method'. A screenshot is retained for scoring the needle tip position on the first attempt. Upon observing backflow, move the ultrasound probe distally along the course of the artery by approximately 0.5 cm; once the needle is shown to have entered the vessel in the long-axis view, advance the needle at an appropriate angle under ultrasound guidance. When the position is satisfactory, withdraw the needle core; if backflow is unobstructed, insert the introducer sheath. If resistance persists, the operator shall decide, based on clinical experience, whether to employ the penetration technique. If insertion fails, withdraw the needle from the radial artery and apply pressure to the puncture site with sterile gauze. After approximately 3 minutes, when there is no significant bleeding at the puncture site, proceed to the next attempt. During this time, the procedure timer shall not be paused, and the number of times the ultrasound probe is repositioned and the needle tip is adjusted shall be recorded throughout the procedure.

Out-of-plane ultrasound guidance Group:

The assistant applies coupling gel to the surface of the ultrasound probe. Working together, the operator and assistant cover the probe with a sterile sleeve, expel any air from between the probe and the sleeve, and evenly apply sterile coupling gel to the outer surface of the sleeve where it will come into contact with the child's skin, thereby completing the preparation of the equipment. To begin positioning, the operator gently places the ultrasound probe 1 cm below the child's wrist crease, ensuring that the short-axis midline of the ultrasound image passes through the radial artery at the centre of the image. The left hand stabilises the ultrasound probe, and positioning is complete. Adjust the ultrasound probe to form an angle of approximately 90° with the skin. Once the midpoint of the probe's short-axis plane aligns with the marked point, insert the 24G arterial puncture cannula with the right hand at an angle of approximately 30° to the skin. Upon observing blood return, capture a screenshot to score the needle tip position for the first attempt. Use the 'dynamic needle tip method' to guide the advancement of the puncture needle. Once the position is correct, withdraw the needle core; if blood return is unobstructed, insert the cannula. If resistance persists, the operator shall decide, based on their experience, whether to use the penetration technique. If insertion fails, withdraw the needle from the radial artery and apply pressure to the puncture site with sterile gauze. After approximately 3 minutes, when there is no significant bleeding at the puncture site, proceed to the next attempt. During this time, the operation timer shall not be paused, and the number of times the ultrasound probe is repositioned and the number of needle tip adjustments shall be recorded throughout the procedure.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The paediatric patient's family fully understands and voluntarily participates in this study, having signed the informed consent form.
  • Paediatric patients undergoing critical surgery requiring radial artery puncture and catheterisation for continuous blood pressure monitoring are selected.
  • ASA physical status classification of I-IV.
  • Age ≤ 24 months, gender not restricted.

Exclusion criteria

  • Paediatric patients who have undergone radial artery puncture within the past month.
  • Paediatric patients with abnormal development of the radial or ulnar arteries, peripheral vascular disease at the radial puncture site, congenital heart disease, or haemorrhagic or cardiogenic shock.
  • Paediatric patients with wounds, infections, or haematomas near the radial puncture site.
  • Ultrasound imaging demonstrating inadequate collateral circulation or a negative Allen test.
  • Cases where the paediatric patient's guardian refuses to sign the informed consent form for study participation.
  • Other circumstances deemed unsuitable for trial participation by the investigator.

Treatment and study plan

T-shaped probe ultrasound guidance

Device

The single-operator laser-assisted T-shaped probe consisted of TuoRen Ultrasonic System(TUR200,shenzhen Tuoren Bio-Medical Electronics Co.,LTD)with a T-shaped probe(L38T7C),a 3D-printed probe-carrying enclosure with a linear laser transmitter( ZLM120AL650-22130BXS,Shenzhen Zhonglai Technology Co.,Ltd)and ultrasonic probe manipulator.

Out-of-plane ultrasound guidance

Device

Ultrasonic(Huasheng Color Ultrasonic Diagnostic System,Navi s,Shenzhen Huasheng Medical Technology Co.,LTD.)

Primary outcomes

  1. Success rate of initial catheterisation attempts without complications

    Time frame: From enrollment to the end of treatment at 2 weeks

Secondary outcomes

  1. First-attempt puncture success rate

    Time frame: perioperative

  2. First-attempt catheterisation success rate

    Time frame: perioperative

  3. overall catheterisation success rate

    Time frame: perioperative

  4. first-attempt needle tip positioning score

    Time frame: perioperative

    Divide the cross-section of the internal jugular vein into 12 quadrants, assigning each quadrant a score based on its position within the quadrant, ranging from a minimum of 1 point to a maximum of 5 points.The Higher the score,the closer it is to the midpoint of the cross-section.

  5. first-attempt needle tip midline positioning rate

    Time frame: perioperative

  6. number of ultrasound probe repositioning attempts

    Time frame: perioperative

  7. number of needle tip adjustments

    Time frame: perioperative

  8. total puncture attempts

    Time frame: perioperative

  9. first-attempt positioning time

    Time frame: perioperative

  10. overall catheterisation completion time

    Time frame: perioperative

  11. Incidence of complications within 3 days after surgery

    Time frame: From enrollment to 3 days after surgery

Sponsors and collaborators

Lead sponsor

The First Hospital of Jilin University

Other

Registry information

Official study title

Out-of-plane Versus Real-time Bi-plane Single-operator Laser-assisted With a Innovative T-shaped Probe for Ultrasound-guided Radial Artery Puncture and Catheterisation in Paediatric: A Randomised Clinical Trial

Important dates

Study start
2026
Primary completion
2026
Study completion
2026
First posted
Mar 6, 2026
Registry last updated
Jul 16, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.