Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT04918316

Initial Correction Keratoconus

Keratoconus is a non-inflammatory, progressive disease in which corneal irregularity increases. As the condition develops, more advanced forms of optical correction are needed to improve vision for patients. Until recently, small diameter corneal gas permeable lenses were considered the primary mode of correction for patients with keratoconus. Now, however, practitioners have multiple options for reducing the optical aberrations caused by keratoconus, including scleral lenses. As of yet, no single option for optical correction has been identified as the preferred mode of correction in terms of overall patient satisfaction with vision, comfort, and ease of use. The order in which various forms of optical correction would be most logically introduced has yet to be determined. This is a study comparing small diameter corneal gas permeable and large diameter scleral lenses in individuals with keratoconus.

This study will prospectively compare visual satisfaction and ease of use between corneal gas permeable and scleral lenses for patients with mild to moderate keratoconus.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Illinois Eye Institute, Chicago, Illinois, United States

Loading trial locations.

About this study

While both corneal gas permeable and scleral lenses have been show to improve visual acuity in individuals with keratoconus, it has yet to be determined if one option has superior comfort and overall patient satisfaction in patients new to gas permeable lens use. In this study, patients will be prospectively fit with both corneal gas permeable and scleral lenses according to standard clinical practice. Both corneal gas permeable and scleral lenses are considered standard of care for patients with keratoconus.

The investigators hypothesize that study participants will select scleral lens over corneal gas permeable lens as their preferred final lens type of choice.

The Primary outcome measure of this study is participant selected final lens choice for continued use for the management of keratoconus.

Methods:

Study Design This is a prospective, multi-center, randomized interventional clinical trial with a 2x2 crossover design of patients with keratoconus fit with corneal and scleral gas permeable contact lenses. The crossover design allows intra-subject differences between two randomized groups with participants serving as their own controls. Contact lens #1 will be the SynergEyes VS (Synergeyes, Inc., Carlsbad CA) which features bi-tangential toric peripheries with linear landing zones. The standard lens is 16.0mm and is available from 14.5 to 17.5mm diameters. Contact lens #2 will be the RoseK2 corneal gas permeable lens (Blanchard Contact Lens, Inc. Manchester, NH). The lens is available in with a base curve range from 4.30 to 8.60 mm, diameter of 7.90 to 10.40mm.

Inclusion criteria

  • Age 18 or older.
  • Diagnosis of keratoconus.
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification of stage 1 or higher

Exclusion criteria

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring

Study procedures During the initial study visits patient demographics, past ocular and medical history and best corrected visual acuity with manifest refraction will be recorded. Additional testing may include corneal topography, pachymetry and meibography. Dry eye symptoms and contact lens comfort will be assessed using the OSDI and CLDEQ questionnaires.

Participants will be fit according to standard practices with the RoseK 2 corneal gas permeable and Synergeyes VS scleral lenses following manufacturer's recommendations. Over refraction and best corrected visual acuity will be recorded. Subjective comfort with lens use rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Participants will be randomized to dispense lens #1 vs lens #2. They will be trained in safe application and removal and provided instructions on lens disinfection procedures. Best corrected visual acuity with lens #1 and subjective comfort with lens use will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the next visit, participants will return wearing lens #1 for minimum of 3 hours. Best corrected visual acuity with lens #1 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the final visit, participants will return wearing lens #2 for minimum of 3 hours. Best corrected visual acuity with lens #2 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

The participant will make a final selection of lens of choice #1 or #2.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Diagnosis of keratoconus
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification9 of stage 1

Exclusion criteria

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring.

Treatment and study plan

Corneal gas permeable lens

Other

Fit in corneal gas permeable contact lens first.

Primary outcomes

  1. Final contact lens choice

    Time frame: At study completion (6-24 weeks)

    Each study participant will select whether to continue with Lens 1 or Lens 2. The percentage of those who choose a Scleral Lens will be compared to the percentage of participants who select corneal gas permeable lenses.

Secondary outcomes

  1. Subjective comfort with lens use

    Time frame: Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)

    Subjective comfort with lens use will be rated by participants on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Sponsors and collaborators

Lead sponsor

University of Illinois at Chicago

Other

Registry information

Official study title

Initial Correction Keratoconus: Scleral vs Corneal Gas Permeable Lenses SCOPE Study

Important dates

Study start
2021
Primary completion
2025
Study completion
2025
First posted
Jun 8, 2021
Registry last updated
Jan 22, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.