NCT Number: NCT03782571
This is a 5-visit, controlled, bilateral, randomized, subject-masked, crossover (4 treatments x 4 period), non-dispensing study. Subjects will attend all study visits in their spectacle correction having not worn contact lenses on the day of the visit.
Looking for future studies?
Notify Me18 year–40 year
All sexes
Interventional
Not applicable
Manchester, M13 9PL, United Kingdom
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
1-DAY ACUVUE® MOIST
1-DAY ACUVUE® MOIST for ASTIGMATISM
1-DAY ACUVUE® MOIST MULTIFOCAL
Bare Eye
Time frame: Post microsphere application over a 30 minute period
The rate of microsphere clearance from the post-lens tear film was assessed by the C30 image analysis metric. Where bare eye was assigned, a droplet of microsphere suspension was applied directly onto the superior temporal conjunctiva. Where lens wear was assigned, the microsphere suspension was dispensed onto the posterior concave contact lens surface immediately prior to lens application. A series of digital images were taken over a 30-minute period (every minute for the first 10 minutes and then every 5 minutes for the next 20 minutes). Data transformed from the images were calculated by the C30 image analysis metric. Higher numbers represented greater clearance. The right eye was used to evaluate microsphere clearance.
Time frame: Post microsphere application over a 10 minute period
The rate of microsphere uptake into the post-lens tear film was assessed by the U5 image analysis metric. Where bare eye was assigned, a droplet of microsphere suspension was applied directly onto the superior temporal conjunctiva. Where a lens was assigned the lens was applied and after a 10-minute settling period, a droplet of microsphere suspension was applied directly to the superior temporal conjunctiva. A series of digital images were taken over a 10-minute period (every minute for 10 minutes). Data transformed from the images were calculated by the U5 image analysis metric. Higher numbers represented greater uptake rate. The left eye was used to evaluate microsphere uptake.
Time frame: Post microsphere application at 30-minute timepoint (OD); post microsphere application at 10-minute timepoint (OS)
Lens movement was assessed for primary gaze, up-gaze, and push up by clinical grading. Primary gaze movement was evaluated by observing the vertical movement of the contact lens that occurs with a full blink without manipulating the subject's lids. Up-gaze movement was assessed by estimating the vertical lens movement observed when the subject looks up and blinks fully without manipulating the subject's lids. The push-up test consists of a gentle digital push of the lens upwards using the lower lid. The resistance of the lens to of the lens to upward movement is judged. Lens movement was graded according to the following scale: Excessive (+2), Moderate movement (+1), Optimal (0), Minimal (-1), and Insufficient (-2). All available data for lens movement in the safety population were reported.
Time frame: Baseline
Corneal curvature was assessed by Visante™ OCT. The following were measured: Sclera Angle-Temporal and Sclera Angle-Nasal.
Time frame: Baseline
Corneal curvature was assessed by Visante™ OCT. Sagital Height was measured.
Time frame: Baseline and the 30-minute post microsphere application time point in the right eye and at the 10-minute post microsphere application timepoint in the left eye.
Blinking characteristics were captured using an infra-red camera (FLIR Grasshopper 3 camera) and infra-red LED illumination (Thorlabs LIU780A). During video capture the subject was directed to view a wildlife video on an Ipad at a working distance of approximately 1 meter. The infrared video was captured for 3 minutes at 500 frames per second. Subsequent video analysis recorded the blink rate (blinks per minute) over the 3-minute period. Baseline values were reported across all subjects who were dispensed a study lens. Blink rate post microsphere application was reported by treatment. All available data for blink rate in the safety population were reported.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details