Kasr Alainy hospitals
Cairo, 11562, Egypt
NCT Number: NCT05368363
1. To estimate sensitivity and specificity of preoperative IVCCI, max aortic diameter and IVC:Ao index as predictors of hypotension after induction of general anesthesia. 2. To compare accuracy of preoperative values of IVC: Ao index to preoperative IVCCI in prediction of hypotension after induction of general anesthesia.
Looking for future studies?
Notify Me18 year–60 year
All sexes
Observational
Cairo, 11562, Egypt
After obtaining approval from the hospital ethics committee, informed consent will be obtained from 102 patients who will undergo elective surgery requiring general anaesthesia in supine position. Patients will be evaluated by history taking and proper examination. Pre-operative investigations will be checked. On the day of surgery, pre-operative fasting for 8 hours will be confirmed.
Upon arrival to the operating room, routine monitors in the form of pulse oximetry, electrocardiogarm and non-invasive blood pressure monitors will be applied. Intravenous line will be secured and routine premedications (ranitidine 50 mg and ondansetron 4 mg) will be administered.
While the patient is lying supine, the IVC and aorta will be examined before induction of general anaesthesia using a curved ultrasound transducer set to abdominal mode with a B-mode scan (1-5 MHz; Acuson x300; Siemens Healthcare, Seoul, Korea).
The transducer is placed in the subxiphoid region in a longitudinal position. IVC measurements are made just distal to the IVC-hepatic vein junction, approximately 3 to 4 cm distal to the right atrium. The IVC is identified by Doppler waveform, compressibility and phasic collapse with respiration. The maximum (IVCDmax) and minimum (IVCDmin) internal anteroposterior (AP) diameters of the IVC at the end of expiration and inspiration respectively over the same respiratory cycle will be measured. The IVCCI is derived from the equation: (7) IVCCI = [ (IVCDmax - IVCDmin) / IVCDmax ] X 100. To the left of the IVC, the abdominal aorta is visualized 10 mm above the coeliac trunk. The maximum internal AP diameter of the abdominal aorta is measured during systole. The IVC:Ao index is derived by taking the ratio of the maximum IVC diameter during expiration and the maximal abdominal aortic diameter during systole.
Standard noninvasive monitoring including ECG, noninvasive blood pressure (BP) measurements every minute and oxygen saturation will be applied. Heart rate (HR), SBP and MBP will be recorded immediately before general anaesthesia and will be defined as baseline readings.
General anaesthesia induction will be started using propofol intravenous anaesthetic (2 mg/kg) and Fentanyl (1 microgram/kg) and Atracrurium non-depolarizing muscle relaxant (0.5 mg/kg).Smooth endotracheal intubation with appropriate sized-cuffed endotracheal tube will be done after 3 mins of manual bag mask ventilation. Confirmation of endotracheal intubation will be done by 3 successive capnography waves and by bilateral lung auscultation. Meanwhile, the noninvasive BP will be recorded immediately after induction, then 5 and 10 minutes post induction, with continuous monitoring of other vital parameters (HR and oxygen saturation) during the postinduction period.
Any episode of hypotension (defined as mean arterial pressure < 80% of the baseline reading or or MAP less than 60 mmHg) will be managed by ephedrine 5 mg every 2 min to increase SBP to 80% of the baseline or MAP more than 70 mmHg. If the hypotensive episode persisted for 2 minutes, another bolus of norepinephrine will be administered. Any episodes of bradycardia (defined as heart rate less than 50 bpm) will be managed by atropine (0.01 mg/kg).
Patients will then be divided into two groups depending on whether they'll develop post general anesthesia induction hypotension or won't. Any complications, such as hypoxia or allergic reaction will be noted and managed accordingly.
The attending anesthesiologist who will perform the induction of general anaesthesia and monitor the patient during the study period will be blinded to the ultrasound measurements of IVCCI and IVC :Ao index recorded pre-operatively.
Measurement tools
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 5 minutes
Area under receiver operating characteristic curves (AUROC) of the preoperative IVCCI inprediction of post-induction hypotension
Time frame: 5 minutes
Correlation between each of maximum aortic diameter with the percentage of themaximum decrease in mean arterial pressure after induction of anesthesia
Time frame: 5 minutes
Correlation between each of IVC collapsibility index with the percentage of themaximum decrease in mean arterial pressure after induction of anesthesia
Cairo University
Other
Accuracy of Preoperative Evaluation of Inferior Vena Cava Collapsibility Index and Caval Aorta Index for Prediction of Hypotension After Induction of General Anaesthesia: "A Prospective Observational Study"
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.