Yonsei University Yongin Severance Hospital
Yongin, Gyeonggi-do, 16995, South Korea
NCT Number: NCT07622485
Patients hospitalized with cardiovascular disease require timely detection of clinical deterioration to prevent adverse outcomes. Standard inpatient care relies on intermittent nursing vital-sign measurements performed every 4 to 8 hours, which can miss hemodynamic or arrhythmic events occurring between measurements. This trial evaluates whether digital wearable-based monitoring - wireless continuous measurement of vital signs and electrocardiography with a real-time alerting system - reduces major adverse cardiovascular events (MACE) compared with standard intermittent monitoring in patients hospitalized for cardiovascular disease. The trial uses a stepped-wedge cluster-randomized design in which four inpatient ward zones (clusters) are sequentially transitioned from standard care to wearable monitoring over five periods.
Trial opening soon.
Get Notified20 year and older
All sexes
Interventional
Not applicable
Yongin, Gyeonggi-do, 16995, South Korea
Study design: This is a prospective, stepped-wedge cluster-randomized, open-label trial with blinded endpoint adjudication, designed to test the superiority of wearable-based monitoring over standard care.
Unit of randomization: The unit of randomization is the inpatient ward zone (cluster), not the individual patient. Four clusters (ward zones 121A, 121B, 122A, and 122B at Yongin Severance Hospital) participate. The trial comprises five periods (one baseline period plus four step periods), each lasting five months. In period 1 all four clusters operate under standard care; thereafter, one cluster per period transitions to the wearable-monitoring intervention in a computer-generated random order, until all clusters are in the intervention state in period 5. Once a cluster transitions to the intervention state it remains so until the end of the trial.
Intervention: Patients admitted to a cluster operating in the intervention state receive continuous wearable monitoring (thynC Inpatient Monitoring System: continuous ECG, heart rate, respiratory rate, oxygen saturation, and body temperature with a real-time central alerting system) in addition to standard care. Patients admitted to a cluster operating in the control state receive standard care (intermittent nursing vital-sign measurement every 4 to 8 hours).
Outcome and follow-up: The primary outcome is the composite incidence of MACE within 6 months. Each participant is followed for 6 months from admission. Total study duration is approximately 36 months (25 months of enrollment, 6 months of follow-up after the last enrolled patient, and 5 months of analysis). Patients and care providers are not masked to allocation; the primary and major secondary endpoints are adjudicated by an independent committee blinded to cluster allocation and study period.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Adults aged 20 years or older
Exclusion criteria
A wearable continuous monitoring system comprising an ECG patch, a temperature patch, and a pulse oximeter that wirelessly transmit continuous vital-sign and electrocardiographic data to a central monitoring system with automated two-tier (Red/Yellow) alerts. Worn from admission until discharge.
Time frame: Within 6 months after admission
Composite of cardiovascular death, myocardial infarction, stroke, unplanned revascularization (PCI or CABG), and cardiovascular rehospitalization, adjudicated by a blinded endpoint adjudication committee.
Time frame: Through hospital discharge, up to 30 days
Incidence of cardiac arrest during hospitalization.
Time frame: Through hospital discharge, up to 30 days
Proportion of patients transferred to the intensive care unit during hospitalization.
Time frame: Through hospital discharge, up to 30 days
Number of days from admission to discharge
Time frame: Through hospital discharge, up to 30 days
Agreement (intraclass correlation coefficient) between wearable-device measurements and reference nursing measurements.
Time frame: Through hospital discharge, up to 30 days
Sensitivity, specificity, and positive and negative predictive values of wearable arrhythmia detection compared with standard ECG/Holter monitoring.
Time frame: Through hospital discharge, up to 30 days
Proportion of vital-sign abnormalities with a clinical response within 30 minutes of the abnormality.
Time frame: Through hospital discharge, up to 30 days
Incidence of adverse events related to the wearable device (skin irritation, allergic reaction, discomfort).
Time frame: Within 6 months after admission
Death attributable to cardiovascular causes, including fatal myocardial infarction, fatal stroke, sudden cardiac death, heart failure death, and death due to other cardiovascular causes, adjudicated by a blinded endpoint adjudication committee.
Time frame: Within 6 months after admission
Non-fatal myocardial infarction defined according to the Fourth Universal Definition of Myocardial Infarction, adjudicated by a blinded endpoint adjudication committee.
Time frame: Within 6 months after admission
Non-fatal ischemic or hemorrhagic stroke confirmed by neuroimaging (CT or MRI) with corresponding neurologic deficit lasting more than 24 hours, adjudicated by a blinded endpoint adjudication committee.
Time frame: Within 6 months after admission
Unplanned percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) performed for clinical indications and not planned at the time of the index hospitalization, adjudicated by a blinded endpoint adjudication committee.
Time frame: Within 6 months after admission
Unscheduled rehospitalization due to a cardiovascular cause, including heart failure, acute coronary syndrome, arrhythmia, or other cardiovascular conditions, occurring after discharge from the index hospitalization, adjudicated by a blinded endpoint adjudication committee.
Contact information is provided by the study sponsor or research team.
Yonsei University
Other
In-Hospital Efficacy and Safety of Wearable-Based Monitoring Versus Standard Care in Cardiovascular Disease: A Stepped-Wedge Cluster Randomized Controlled Trial (INSPIRE Trial)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07721649
Acute Coronary Syndrome, Behavior
Cologne, Germany
View Trial DetailsNCT03987633
Arrhythmias, Cardiac, Arterial Occlusive Diseases
Wolverhampton, West Midlands, United Kingdom
View Trial DetailsNCT06265714
Acute Coronary Syndrome, Brain Diseases
Denpasar, Bali, Indonesia
View Trial DetailsNCT01804439
Abdominal Aortic Aneurysm, Acute Myocardial Infarction
View Trial Details