Skip to main content
OpenTrials
Completed

NCT Number: NCT03182361

Implant Survival and Peri-abutment Tissue Reactions of Extra-oral Implants.

Patients with craniofacial defects caused by oncologic resection, traumatic events or congenital etiologies suffer from esthetic, functional and psychological problems. Auricular, nasal and orbital defects can be reconstructed with implant retained extra-oral prosthesis. The goal of this study is to evaluate implant survival in temporal, maxillary and orbital bone, and peri-implant tissue reactions using a new implant system developed by BioComp Industries.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University Hospital

Ghent, Oost-Vlaanderen, 9000, Belgium

About this study

Protocol:

  • Planning The ideal size and location of the implants is based on pre-operative CT or CBCT scan followed by analysis using romexis planning software.

In normal circumstances, without bone limitations, the number and location of the implants will be planned as mentioned below:

  • Left auricular region: 2 implants placed on position 4h and 1h30 in the temporal/mastoid bone. If necessary, 3 implants are placed on positions 1h30, 3h and 4h30. The inter implant distance is 20mm.
  • Right auricular region: 2 implants placed on position 8h and 10h30 in the temporal/mastoid bone. If necessary, 3 implants are placed on positions 10h30, 9h and 7h30. The inter implant distance is 20mm.
  • Nasal region: 2 implants placed in the lateral parts of the piriform aperture of the maxilla, as far away from the spina nasalis anterior as possible. If necessary a third implant will be placed in the glabella.
  • Left orbital region: 2-4 implants are placed in the supra-orbital, lateral and/or infra-orbital rim on positions 1h, 2h, 3h en 5h.
  • Right orbital region: 2-4 implants are placed in the supra-orbital, lateral and/or infra-orbital rim on positions 11h, 10h, 9h en 7h.

If for some reason there is insufficient bone in the above mentioned areas, the position of the implants will be minimally adjusted in order to secure good osseointegration. Neuronavigation will be used for cases with limited bone volume.

  • Flap design During surgery the first step is the creation of a skin flap or resection of a tumor, exposing the area for implantation.
  • Implantation The implantation protocol as described by BioComp Industries will be used. Each drilling procedure is executed by 1800-2000rpm with water cooling.
  • Defining the implant location with the 2,45mm diameter round bur.
  • Preparation of the implant site with the implant drills, length and diameter of the drill is dependent on the length and diameter of the implant. Drilling protocol will always start with the smallest and shortest drill and gradually expanded, corresponding to the size of the implants.
  • Placement of the implant without water cooling at 15rpm and maximal torque of 52Ncm. If necessary the implant will be inserted manually.

For auricular, orbital and nasal defects with sufficient bone volume (>=3mm) and good bone quality, a percutaneous healing abutment with torque 20-25 ncm will be placed immediately after insertion of the implant (=one-stage protocol). Soft tissues in an area of 15-20mm surrounding the implant will be reduced to 1mm thickness.

In all other circumstances, the implant will be protected by means of a cover screw and reburied under the skin for a 3 month osseointegration period (=two-stage protocol). After 3 months the implants are exposed, percutaneous healing abutments placed and the surrounding soft tissues reduced to 1mm thickness.

In the case of large resections where no viable skin is left, a split thickness skin graft from the upper thigh will be used.

Finally, a healing cap surrounding the healing abutments is placed to ensure strong bone-skin contact around the implant. This healing cap will be fixated by a fixation screw, torqued at 15 Ncm.

  • Clinical measurements:

The stability of the implants will be measured at the time of abutment placement, 1 or 2 weeks, 1 month, 3 months, 6 months and yearly until the end of the study by resonance frequency analysis (RFA), using the Osstell idx system.

At the same time periods the peri-abutment tissue will be evaluated according to the Holgers criteria.

Once all implants have reached a stability measurement of 50 ISQ, the patient will be sent to the anaplastologist for prosthesis treatment.

In case one or more of the implants fail during the study period, the implant will be removed and replaced by a new implant. The protocol will restart for the newly placed implant.

  • Radiological measurements:

The bone level around the implants will be measured at 1 or 2 weeks after implant placement and 1 year after implant placement. Radiological imaging will be performed using a cone beam computed tomography device (planmeca promax 3d max) or CT scan, dependent on primary imaging in order to allow comparison between both images.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All patients with auricular, nasal, orbital defects caused by congenital, traumatic, oncologic or infectious etiologies
  • Adults (>18yr)

Exclusion criteria

  • Children
  • Implant placement for bone anchored hearing aid (BAHA)
  • Implant placement for oral rehabilitation

Treatment and study plan

Implantation of BioComp Industries cranio-maxillo-facial (CMF) screw implants

Device

Placement of BioComp Industries extraoral screw implants with diameters 3.4mm or 4mm and lengths 3.4mm or 4mm in temporal, nasal or orbital bone

Other names: EO-1110-34VD04, EO-1110-40VD03, EO-1110-40VD04

Primary outcomes

  1. Implant survival

    Time frame: 1 year

    Implant stability measurement with Osstell IDX system

  2. Peri-implant tissue reaction

    Time frame: 1 year

    Measurement of peri-implant pockets and soft tissue according to Holgers criteria

Secondary outcomes

  1. Bone level

    Time frame: 1-2 weeks post-operative, 1 year

    Bone level measurement using CBCT or CT scan

Sponsors and collaborators

Lead sponsor

University Hospital, Ghent

Other

Collaborators

  • BioComp Industries bv

Registry information

Official study title

Implant Survival and Peri-abutment Tissue Reactions of Extra-oral Implants: An Interventional Study of 10 Patients

Important dates

Study start
2017
Primary completion
2019
Study completion
2019
First posted
Jun 9, 2017
Registry last updated
Dec 23, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.