Cook Flexor
Deviceureteral access sheath
NCT Number: NCT03349099
The purpose of this study is to assess whether one of two ureteral access sheaths is safer for patients undergoing ureteroscopy. Both sheaths are FDA approved devices and commercially available. The investigators will compare the ability of sheaths to access the kidney through the ureter and will compare damage done to the ureter after completion of the procedure. Access sheaths are standard of care for this procedure; this study seeks to optimize outcomes for patients.
Patients undergoing ureteroscopy who do not have ureteral stents in place and who have not had an ipsilateral procedure within 90 days will be recruited and consented.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
The purpose of this study is to compare two ureteral access sheaths in how the sheaths damage the ureter during flexible ureteroscopy.
Condition Intervention Kidney Stones Nephrolithiasis Urolithiasis Device: Cook Flexor or Boston Scientific Navigator HD
Study Type: Interventional Study Design: Intervention Model: Two group randomized assignment Masking: Single blind Primary Purpose: Treatment
Primary Outcome Measures:
Secondary Outcome Measures:
Arms Assigned Interventions Device: Cook Flexor and Boston Scientific Navigator HD Device: Cook Flexor or Boston Scientific Navigator HD Patients will be assigned to one of two ureteral access sheaths. If the first sheath is failed to be placed, the backup sheath will be attempted.
Standard ureteroscopy will take place. The intervention takes place before the ureteral access sheath is placed. The patient will be randomized to one of the two sheaths. The randomized 12/14Fr sheath will be attempted. If placed successfully, the rest of the operation continues as planned. If the initial sheath is unable to be placed, a second backup sheath (opposite brand) will be used, also in size 12/14Fr. The surgeon will be asked to rate the ease of placement of the sheath on a standardized scale. If these sheaths fail, it is the surgeon's discretion to continue with the smaller sheath, continue without sheath or place stents and attempt the procedure at a later date. The operation is then continued in standard fashion. Once the ureteroscopy is completed, before the scope and access sheath are removed, video recording of the ureter will be conducted as the ureteroscopy and sheath are removed.
Videos will be analyzed by blinded urologists who will rate the extent of ureteral damage on a standardized scale of 0 to 4 according to the study published by Traxer et al. 2013. Intra-operative data includes total time of initial sheath insertion (in seconds), total time sheath is in place (minutes) from placement to removal, and use of laser. Differences in operative time, ease of placement, ability to maintain access, and ease of instrument passage are also evaluated between devices, as well as success rates, and device failure rates and post-operative complications. Means are compared using a t-test and proportions are compared using a chi-squared test. An intention to treat model is used for statistical analysis. When video ratings differ between surgeons, the higher rating of damage will be used. Inter-rater reliability is assessed with Cohen's kappa coefficient.
After the study, subjects will not be contacted. The investigators will collect data from participants' medical records including information of whether participants develop complications or return for a subsequent procedure as well as size and location of kidney stones prior to the surgery.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
ureteral access sheath
ureteral access sheath
Time frame: One time point - at the beginning of the procedure
The surgeon documents whether there was Successful placement of sheath (yes or no)
Time frame: One time point - at the completion of the procedure
Subjective rating of damage to ureter. At the completion of the procedure, video of the intraluminal ureter is recorded as the sheath is withdrawn. Videos are analyzed by two blinded staff endourologists who score ureteral injury on a standard 5-point scale (0 to 4); reference Traxer and Thomas.
Time frame: One time point - at the completion of the procedure
Surgeons will be asked to subjectively rate the ease of placement on a standardized scale from 0 to 4, 4 being easiest which will be rated by the surgeon who inserted the sheath immediately after placement.
The Cleveland Clinic
Other
The Impact of Ureteral Access Sheath Design on Ease of Placement and Ureteral Wall Injury During Flexible Ureteroscopy
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04519294
Calculi, Female Urogenital Diseases
Phoenix, Arizona, United States
View Trial DetailsNCT04695951
Calculi, Female Urogenital Diseases
Managua, Nicaragua
View Trial DetailsNCT04998435
Agnosia, Analgesia
Cairo, Egypt
View Trial DetailsNCT04819828
Female Urogenital Diseases, Female Urogenital Diseases and Pregnancy Complications
View Trial Details