Mechanism and Effects of Manipulating Chloride Homeostasis in Acute Heart Failure
NCT03446651
Cardiovascular Diseases, Heart Diseases
New Haven, Connecticut, United States
View Trial DetailsNCT Number: NCT01008670
The primary goal of this study is to develop techniques to identify the course of the phrenic nerve in patients already undergoing cardiac resynchronization therapy (CRT) implantation or candidates for future CRT devices undergoing implantable cardioverter-defibrillator (ICD) or pacemaker implantation. Specifically, the study intends to identify the location and course of the left pericardiophrenic vein, and thus the left phrenic nerve, to guide the location for coronary vein lead placement and minimize the risk of phrenic nerve stimulation.
Looking for future studies?
Notify Me18 year–85 year
All sexes
Observational
Ruhr University of Bochum, Bad Oeynhausen, Germany
Phrenic nerve stimulation from cardiac resynchronization therapy (CRT) is a common adverse event occurring in 1.5-3% of patients and sometimes as high as 10%. Phrenic nerve stimulation is frequently observed during the implantation procedure but often appears shortly after implantation as well. Clinically, dyspnea, cough, and hiccups can occur, some of which are uncomfortable and not tolerated by the patient for very long periods of time. Resolution of these clinical outcomes requires repositioning the left coronary vein lead in a second procedure with its attendant serious clinical sequelae. As CRT leads become smaller the incidence of phrenic nerve stimulation is likely to increase.
The risk of phrenic nerve stimulation (PNS) exists during CRT implantation and is only minimally dependent of the type of coronary lead and highly dependent upon location of the left coronary vein lead in relationship to the left phrenic nerve and stimulation strength. Tedrow et al. demonstrated in a cohort of 71 patients PNS can reach 16% if stimulation strength is increased to maximize mechanical benefit of CRT. No current methods have been able to predict PNS, the one likely method of preventing PNS is to identify the location of the phrenic nerve in the specific patient, as confirmed by visualization and ability to stimulate the phrenic nerve and by maximizing the distance between the coronary vein lead position and nerve.
In order to reduce the incidence of phrenic nerve stimulation, Vaseghi performed non-selective injections of contrast media and was able to identify the left pericardiophrenic vein in only about 12% of patients undergoing biventricular pacemaker placement. However, in these patients, identification of the left pericardiophrenic vein provides a landmark for positioning of the left ventricular (LV) lead that totally eliminated the incidence of phrenic nerve pacing.
The relationship of cardiac structures to the right and left phrenic nerves is generally known but is significantly variable between patients. There is no imaging or other clinically available modality that allows the physician to identify the location of the left phrenic nerve and attempt to avoid it during the left coronary vein lead implant procedure.
The pericardiophrenic veins are a deep collateral venous drainage of the pericardium, pleura and diaphragm and lie adjacent the phrenic nerves on both the right and left sides between the parietal pericardium and adjacent pleura. The ostium of the left pericardiophrenic vein is usually in the left brachiocephalic vein opposite the entrance of the left jugular vein. The left phrenic vein is located in the general vicinity of the thymic veins which often have multiple ostia in close proximity. There are several case reports in the literature of inadvertent cannulation of the pericardiophrenic veins with Swan-Ganz catheters, central venous catheters and one report of cannulation with a pacing lead leading to inadvertent phrenic nerve pacing.
The primary goal of this study is to develop techniques to identify the course of the phrenic nerve in patients already undergoing cardiac resynchronization therapy (CRT) implantation or candidates for future CRT devices undergoing implantable cardioverter-defibrillator (ICD) or pacemaker implantation. Specifically, the study intends to identify the location and course of the left pericardiophrenic vein, and thus the left phrenic nerve, to guide the location for coronary vein lead placement and minimize the risk of phrenic nerve stimulation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Methods are assessed acutely (during the lead implant procedure)
Respicardia, Inc.
Industry
Acronym: IDPV-003
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03446651
Cardiovascular Diseases, Heart Diseases
New Haven, Connecticut, United States
View Trial DetailsNCT05806606
Behavior, Cardiovascular Diseases
Hong Kong
View Trial DetailsNCT06847438
Cardiovascular Diseases, Heart Diseases
Atlanta, Georgia, United States
View Trial DetailsNCT07721909
Cardiovascular Diseases, Heart Diseases
Muscat, Oman
View Trial Details