Completed

NCT Number: NCT02602912

Identification of Spine Structures by Using BIP-Needles

The main purpose of the study is to assess the feasibility and clinical performance of impedance based tissue identification in various spine structures.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Tampere University Hospital

Tampere, FI- 33521, Finland

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Voluntary adult patients going through medical operation involving spinal puncture, spinal fluid sampling or intrathecal drug injection.

Exclusion criteria

  • Participation to other clinical study
  • Exclusion criteria are the same as generally for spinal anaesthesia and lumbar punctures. Exclusion criteria includes infection on skin area, systemic anticoagulation, sepsis, anatomical unsuitability and refusal
  • In addition for not giving (or not capable to give) the consent personally for any reason is an absolute exclusion criterion. In practice this means that study is for adult patients only.

Treatment and study plan

Injeq Bioimpedance Probe (BIP) Needle

Device

Injeq Bioimpedance Probe (BIP) Needle is a spinal needle that has bioimpedance measurement capability. It consists of traditional needle cannulae and removable bioimpedance probe which enables the measurement of bioimpedance. The needle is connected to measurement device and tissue identifying algorithm. Bioimpedance is measured during the operation and the algorithm detects when the needle tip is in contact with cerebrospinal fluid.

Primary outcomes

  1. True positive and false positive detection of cerebrospinal fluid marked in case report form

    Time frame: During spinal puncture

    Measurement device indicates with a sound and visual feedback when needle reaches cerebrospinal fluid (CSF). Physician verifies the location by removing the needle stylet and testing whether CSF flows from the needle, similarly as in traditional process. Detection is true positive if CSF flows from the needle and false positive if not. Even if the device does not detect the spinal fluid, physician performs the CSF test when needed. Physician marks to the case report form whether the device provided detections during the spinal puncture and were the detections true or false detections.

Sponsors and collaborators

Lead sponsor

Injeq Ltd

Industry

Registry information

Official study title

INJ-SPINE-01 Identification of Spine Structures by Using BIP-Needles

Important dates

Study start
2015
Primary completion
2018
Study completion
2018
First posted
Nov 11, 2015
Registry last updated
Feb 27, 2019