Royal Hallamshire Hospital
Sheffield, South Yorkshire, S10 2JF, United Kingdom
NCT Number: NCT03298776
The use of endoscopy for the diagnosis of gastrointestinal diseases has continued to increase in recent years.
Endoscopy provides an advantage over other noninvasive or minimally invasive procedures in that it allows both direct visualisation of the mucosa but direct and accurate sampling of abnormalities for histological examination. However standard endoscopy does have some limitations particularly with small lesions and pan mucosal changes. Some lesions may be entirely benign and require no further intervention but as a result of difficulty with accurate endoscopic characterization of lesions in many cases unnecessary biopsies or polypectomies are undertaken. Therefore any technology that can augment the use of standard endoscopy to minimise unnecessary intervention should be encouraged. IScan is a digital enhancement technique available with Pentax endoscopes. There have been other novel endoscopic advances for example, Narrow band imaging but these have not been adopted widely for a number of reasons including technical difficulties or patient tolerability. The aim of this study is to assess whether Pentax IScan technology is a reliable method of improving our recognition of macroscopic mucosal lesions compared to standard white light endoscopy
Looking for future studies?
Notify Me16 year and older
All sexes
Interventional
Not applicable
Sheffield, South Yorkshire, S10 2JF, United Kingdom
All patients recruited will undergo standard endoscopy using current generation Pentax endoscopes. These endoscopes are widely used for standard endoscopic procedures. All of the endoscopes that will be used have the I-scan function which is controlled by the operator. Therefore there will be no difference between the groups randomised to I-Scan or standard endoscopy, other than a very slight difference in duration for I-scan, which the patient is unlikely to detect. We have received no funding from Pentax for the use of their endoscopes.
Following recruitment patients will be randomly allocated to receive standard white light endoscopy or standard white light endoscopy plus I-Scan using a random number generator at www.random.org with possible values of 0 or 1. Those with a 0 will receive standard endoscopy and those with a 1 will receive standard endoscopy plus I-Scan. Both arms will undergo standard endoscopic evaluation including appropriate biopsies by fully trained experienced endoscopists with Joint Advisory Group (JAG) accreditation for endoscopy. The investigators will be initially blinded to the indication for endoscopy until the I-Scan has been utilised at which point the indication will be revealed to ensure patient safety. Patients will have biopsies only by the clinical indication. No extra biopsies that would not normally be clinically justified will be taken. Following the procedure all patients will be asked to evaluate the tolerability of their test using a validated 10 point likert scale. All procedures will be recorded on an anonymised basis using a unique research identifier and subsequently reviewed by other expert endoscopists within the department to allow us to accurately assess the reliability and interobserver variability of the test. Each of the endoscopists will be fully trained in standard endoscopy and will be blinded to the indication for the procedure.
The study will be a randomised controlled trial. Given the nature of the study it is not possible to blind the investigators to the procedure type. The investigator carrying out the procedure will however be blinded to the indication for the procedure until the I-Scan has been used as this could lead to bias. The endoscopists reviewing the images will be blinded to all patient information and indications for the endoscopy throughout the study period.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
I-Scan is a digital enhancement technique. These endoscopes already have greater definition compared to many standard endoscopes but they also utilise a 'zoom' function and digital image enhancement.
Patients referred for standard endoscopy to receive standard of care only
Time frame: through study completion, on average one year
The endoscopic assessment of mucosal lesions using standard endoscopy and standard endoscopy plus I-Scan Will be compared to histological assessment where this is indicated. Interobserver variability of assessment of mucosal lesions will be compared between endoscopic techniques
Time frame: through study completion, on average one year
The use of the I-scan results in a slight prolongation of the endoscopy procedure. A ten point likert patient reported questionnaire will assess patient tolerability of the I-scan
Sheffield Teaching Hospitals NHS Foundation Trust
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04660214
Digestive System Diseases, Diverticular Diseases
Valladolid, Spain
View Trial DetailsNCT06645457
Anxiety, Anxiety Disorders
Muğla, Turkey (Türkiye)
View Trial DetailsNCT07360041
Calculi, Calculus
Cairo, Cairo Governorate, Egypt
View Trial DetailsNCT07143435
Anemia, Anemia, Hypochromic
Kassala, Sudan
View Trial Details