National Heart Centre Singapore
Singapore, 169609
Location status: Recruiting
NCT Number: NCT06645691
Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan. Carbon-13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal . Whilst the role of 13C imaging has been demonstrated in many sites around the world, we aim to demonstrate the feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular and/or cardiometabolic diseases.
Interested in participating?
Request Info21 year–99 year
All sexes
Interventional
Phase 2
Singapore, 169609
Location status: Recruiting
Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan.
Carbon 13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. However, the low natural abundance of the 13C isotope at ~1.1% has made in vivo imaging extremely challenging. To improve the MR signal 13C nuclei, probes are synthetically enriched to increase the concentration of the 13C label in a molecule. MRI signal can be further increased by the process of hyperpolarization. At low temperature and high magnetic field, electrons have a very high level of polarization (ie, nearly all the electrons are aligned in the same direction). This high level of polarization can be transferred to 13C-labeled probes, increasing their MRI signals. This transfer of polarization is accomplished by mixing radicals (a source of free electrons) with the 13C-labeled probe(s) to be hyperpolarized and placing the mixture in a polarizer at a magnetic field typically of 3.0-5.0 T and at a low temperature (approximately 1 K). Microwave irradiation is then applied to transfer the polarization from unpaired electrons in a trityl radical to the 13C-labeled probe. The final solution retains a high level of polarization and can be formulated to be at physiologic pH, osmolarity, and temperature for in vivo injection and metabolic investigations.
With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal (Figure 1). The enhanced signal, however, is typically available only for a short period of time (1-2 minutes), as the polarization decays back to its thermal equilibrium level. Therefore, rapid imaging is needed to acquire high signal-to-noise ratio metabolic data with minimal polarization loss and to measure fast metabolic processes.
To date, hyperpolarized imaging technique has been performed in more than 800 healthy volunteers and patients; and in more than 1,200 studies in various clinical conditions.
HYPOTHESIS AND OBJECTIVES:
This proof-of-concept study to demonstrate feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular/cardiometabolic diseases.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Healthy Volunteers:
Patients with cardiovascular/cardiometabolic diseases:
Exclusion criteria
Hyperpolarized 13C-pyruvate is injected intravenously at a dose of 0.43 mL/kg body weight, and at a rate of 5 mL/second followed by a 20 mL saline flush at 5 mL/second when the patient is already in the MRI scanner
Other names: (13C) pyruvate, Hyperpolarized Carbon C 13 Pyruvate
Time frame: 30 - 45 minutes post dose
Feasibility and reproducibility of the imaging technique in healthy volunteers and patients with cardiovascular and/or cardiometabolic diseases
Contact information is provided by the study sponsor or research team.
National Heart Centre Singapore
Other
Acronym: POLARIC-13
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06371937
Arrhythmias, Cardiac, Arrythmia
London, Ontario, Canada
View Trial DetailsNCT07041827
Cardiomyopathies, Cardiotoxicity
Amsterdam, North Holland, Netherlands
View Trial DetailsNCT03713333
Arrhythmias, Cardiac, Atrial Fibrillation
Morgantown, West Virginia, United States
View Trial DetailsNCT07482943
Cardiovascular Abnormalities, Cardiovascular Diseases
Hong Kong
View Trial Details