Stanford University
Stanford, California, 94305, United States
NCT Number: NCT02199028
This research study examines the effect of hyaluronidase on the length of time of insulin infusion set wear. The aim of the study is to improve the length of time that an infusion set can be worn by infusing hyaluronidase directly into the insulin infusion site.
Looking for future studies?
Notify Me12 year–45 year
All sexes
Interventional
Phase 1
Stanford, California, 94305, United States
The investigators would like to see if the use of hyaluronidase will improve insulin infusion set survival and improve the onset of insulin action. The investigators will also assess the accuracy of the Dexcom G4P sensors with extended site use beyond the 7 day FDA approved time frame.
The use of sensor information combined with the knowledge of infused insulin from pump therapy could potentially help us detect when an infusion set is beginning to fail. Information from the sensor function to the point of failure, and sensor function in response to Tylenol may allow us to develop special formulas to determine when a sensor is not working well. This will be very important for creating an artificial pancreas.
Thirty subjects will be enrolled. Fifteen patients from each of the two sites: Stanford University and University of Colorado.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
150 units/ml - subjects injected 1 milliliter (ml) into the catheter hub prior to connecting the insulin infusion set on Day 1 and 3 of infusion set wear.
Other names: Hylenex
No hyaluronidase administered into insulin infusion set.
Time frame: Up to 4 weeks
Average (mean) days of wear are presented for each group. A longer period of wear was considered a better outcome.
Time frame: Up to 24 hours post infusion
The effects of hyaluronidase on post-prandial glucodymamic parameters is presented as the estimated glycemic excursion, a composite value which was calculated based on peak glucose concentration (Cmax), time to Cmax (Tmax), time to early half-maximal glucose concentration (t50%), time to late t50%, and area under the curve (AUC) of glucose concentrations at time intervals of 120 and 240 minutes, with or without hyaluronidase. Estimated glycemic excursion for a patient with Type 1 diabetes that is less than 80 mg/dL is considered acceptable.
Time frame: Up to 4 weeks
Patients recorded pain experience at the infusion site (at time of injection and pain each day of wear) in subject diaries on a 0-5 pain scale (0 = no pain and 5 = worst pain imaginable).
The number of diary entries are presented by scale category.
Stanford University
Other
Evaluation of Glucose Sensor and Insulin Infusion Set Failures: Hyaluronidase Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07696039
Autoimmune Diseases, Diabetes Mellitus
Bergamo, Italy
View Trial DetailsNCT03263494
Autoimmune Diseases, Diabetes Mellitus
Los Angeles, California, United States
View Trial DetailsNCT07090824
Autoimmune Diseases, Diabetes Mellitus
Palo Alto, California, United States
View Trial DetailsNCT05211479
Adolescent, Anxiety Disorders
Yalova, Turkey (Türkiye)
View Trial Details