High-frequency-ultrasound Annular Arrays for Ophthalmic Imaging

The objective of this research is to improve the care of ocular disease and disorders, in particular the changes in the eye associated with diabetes, by providing clinicians with dramatically improved ultrasonic images of the entire eye. The research combines advanced high-frequency, high-resolution ultrasonic annular arrays transducers with new processing techniques designed to overcome several limits that have been reached with conventional high-frequency ultrasound systems. We propose that diagnosis of eye diseases using annular arrays can be more effective than the conventional ultrasound images by at least 50%; i.e., that for every 2 posterior vitreous detachments detected conventionally, 3 will be detected with the annular arrays.

Completed

Looking for future studies?

Notify Me

Key information

Age range

60 year–85 year

Sex eligibility

All sexes

Study type

Observational

Primary location

Weill Cornell Medical College

New York, 10065, United States

About this study

In this study, we will deploy annular-array systems and assess their experimental and clinical utility for ophthalmic imaging. We hypothesize that a 20-MHz annular array will detect posterior vitreous detachment (PVD) more reliably than a conventional single element ultrasound system. Clinically, we will test the hypothesis that 20-MHz annular arrays improve detection of PVD, an important risk factor for disease progression in diabetic retinopathy. Diabetic retinopathy is the leading cause of blindness in the working population (25 to 65 years) and the third major cause of legal blindness in the U.S.

We propose to carry out a study of 30 human subjects, aged 60 years or above, in whom PVD is likely to be present as a consequence of normal aging. The study will compare the ability to detect PVD using a commercial ophthalmic ultrasound system equipped with 10- and 20-MHz sector scan probes (Cinescan A/B-S, Quantel Medical), and OCT (OCT/SLO, Ophthalmic Technologies, Inc.), and the 20-MHz annular array. The annular array will be used with synthetic focusing and simulated single-element mode. The end point will be the fraction of eyes in which the PVD is visualized with each technique. This comparison is designed to demonstrate the improvement in our ability to visualize this pathologic entity using the advanced signal processing modes to be explored in this study. PVD can represent a risk factor for retinal detachment and retinal neovascularization in diabetics and localization of vitreoretinal traction points may be crucial for management. The present study, however, is limited to visualization of PVD in older normal subjects, about 75% of which would be expected to have PVD present. Thus, our aim is purely to develop an improved imaging modality rather than demonstrating its clinical efficacy in management of diabetic retinopathy or other ocular diseases.

The imaging technologies that we are developing could potentially result in patents or other intellectual property, which would be managed by the Cornell Research Foundation and Riverside Research Institute. This is alluded to in the consent form for the sake of completeness.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects should be age 60 or older with possible posterior vitreous detachment in the back of the eye.

Exclusion criteria

  • none

Treatment and study plan

ultrasound examination

Procedure

Immersion Ultrasound Exam: In the immersion technique, the patient lies down on the examination table. A steridrape with a central aperture is used to form a water-tight seal around the eye. After installation of 2 drops of 0.5% proparacaine HCl, a wire lid speculum is used to hold the patient's lids open. Warm 0.9% sterile saline solution is then used to create a waterbath about 1/2 inch deep to provide acoustic coupling between the transducer and the eye. The transducer (either the 10- and 20-MHz sector scan probe or the annular array) is placed in the waterbath, but does not touch the eye.

Primary outcomes

  1. detection of PVD in the posterior pole

    Time frame: outcome measured at time of examination

Sponsors and collaborators

Lead sponsor

Weill Medical College of Cornell University

Other

Collaborators

  • Riverside Research Institute

Registry information

Official study title

High-frequency-ultrasound Annular Arrays for Small Animal and Ophthalmic Imaging

Important dates

Study start
2008
Primary completion
2010
Study completion
2010
First posted
Mar 12, 2008
Registry last updated
Mar 28, 2019