High Frequency Light and Sound Stimulation to Improve Brain Functions in Alzheimer's Disease

Alzheimer's disease (AD) is characterized by significant memory loss and toxic protein deposits (amyloid and tau) in the brain. The investigators' lab found a non-invasive way to remove these toxic proteins from the brain in AD mouse models. Remarkably, treated mice also have improved memory on behavioral testing. The investigators aim to translate this non-invasive method, which uses light and sound to stimulate the brain, to be used in mild Alzheimer's patients. 40 participants with mild Alzheimer's disease will be recruited, and the investigators will assess their brain waves with electroencephalogram (EEG) before, during, and after light and sound stimulation for safety, feasibility, and to optimize the stimulation device for use in the mild AD population.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Key information

Age range

50 year–100 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Massachusetts Institute of Technology

Cambridge, Massachusetts, 02139, United States

About this study

It is known that Alzheimer's disease (AD) patients have significant disruptions in brain waves, especially the gamma frequency (~30 - 100 Hz) waves. Recently, the investigators' lab found that gamma entrainment using light and sound stimulation, which the investigators call GENUS, improves memory and decreases toxic accumulation of amyloid and tau in AD mouse models. This study aims to translate these findings in the mouse models to be used in mild Alzheimer's patients. The investigators will recruit 40 patients diagnosed with mild AD who will be randomly assigned to two study arms. Cognitive and mental health evaluations as well as memory tests will be performed on all subjects. All subjects will also be exposed to the GENUS device, which can deliver light and sound waves at different frequencies. The GENUS device is composed of a panel with light-emitting diode (LED) illumination and speakers for auditory stimulation. Each of the 2 groups will have different combinations of light and sound settings. The investigators will use electroencephalography (EEG) to check for how the participant's brain waves respond to the stimulation, and use questionnaires to evaluate for safety and tolerability.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subject is between the ages of 50 - 100.
  • Subject must have mild Alzheimer's disease with a Mini Mental State Exam (MMSE) score of 19 -26.
  • Subject is willing to sign informed consent document.
  • If subject is deemed to not have capacity to sign the informed consent, he/she will need a legally authorized representative to provide surrogate consent.

Exclusion criteria

  • Subjects who do not have healthcare.
  • Subjects who are being treated with N-methyl-D-aspartate (NMDA) receptor antagonists (eg. Memantine).
  • Subjects on medications that lower seizure threshold such as wellbutrin, ciprofloxacin, levofloxacin, etc.
  • Subjects with history of seizure or epilepsy within the past 24 months.
  • Subjects with clinically significant suicide risk and/or suicide attempt in the past 1 year.
  • Subjects with behavioral problems such as aggression/agitation/impulsivity that might interfere with their ability to comply with protocol.
  • Active treatment with one or more anti-epileptic agent.
  • Subjects who have had a stroke within the past 24 months.
  • Subjects diagnosed with migraine headache.
  • Active treatment with one or more psychiatric agent (e.g. antidepressants, antipsychotics, etc).
  • Subjects who have an active implantable medical device including but not limited to implantable cardioverter defibrillator (ICD), deep brain stimulator (DBS), cardiac pacemaker, and/or sacral nerve stimulator.
  • Subjects who have profound hearing or visual impairment.
  • Subjects who have a life expectancy of less than 2 years.
  • Subjects who are pregnant.

Treatment and study plan

GENUS device (Active Settings)

Device

Participants in the experimental group will use the GENUS device configured to active settings for 30 - 60 minutes.

Other names: Gamma frequency stimulation, Light and sound stimulation

GENUS device (Sham Settings)

Device

Participants in the control group will use the GENUS device configured to sham settings for 30 - 60 minutes.

Other names: Gamma frequency stimulation, Light and sound stimulation

Primary outcomes

  1. Feasibility of gamma frequency stimulation

    Time frame: Immediately after the completion of the stimulation

    Feasibility of gamma frequency stimulation in subjects with mild AD will be assessed by analyzing the EEG data from each subject for a sign of change in gamma frequency waves and determining the percent of subjects who show this change.

  2. Tolerability of gamma frequency stimulation

    Time frame: Immediately after the completion of the stimulation

    Tolerability of gamma frequency stimulation will be assessed by using a questionnaire asking for the subjects' overall experience with the stimulation.

  3. Safety of gamma frequency stimulation

    Time frame: Immediately after the completion of the stimulation

    Safety of gamma frequency stimulation will be assessed by using a questionnaire asking for any adverse effects of the stimulation.

Other outcomes

  1. Changes in working memory after gamma frequency stimulation

    Time frame: Baseline and immediately after the completion of the stimulation

    Exploratory measure to check if there is any change in n-back test performance, between baseline and immediately after the completion of the stimulation.

    The n-back test involves a sequence of stimuli (e.g., letters, numbers), presented one at a time, and a subject is asked to indicate when the current stimulus is the same as the stimulus presented n times earlier in the sequence. The performance metrics will include the "hit" rate (number of correct responses out of total number of target stimuli; ranging from 0 to 1), "false alarm" rate (number of incorrect responses out of total number of non-target stimuli; ranging from 0 to 1), and response time.

Sponsors and collaborators

Lead sponsor

Massachusetts Institute of Technology

Other

Registry information

Official study title

Acute Treatment of Alzheimer's Disease With Gamma Frequency Stimulation

Important dates

Study start
2019
Primary completion
2026
Study completion
2027
First posted
Aug 2, 2019
Registry last updated
Oct 1, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.