NCT Number: NCT00811109
The purpose of this randomized controlled study is to compare the effects of different new dialysis on-line monitoring devices on hemodynamic stability during intermittent hemodialysis in critically ill patients with acute kidney injury.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 2 / Phase 3
Caen, 14000, France
Acute kidney injury (AKI) is associated with high mortality and morbidity rates in critically ill patients despite advances in renal replacement therapy (RRT). Over the last few years, new devices in dialysis equipment, such as blood temperature and blood volume on-line monitors, have been developed to improve hemodynamic tolerance, and these new modalities have demonstrated their positive impact on decrease in intra-dialytic hypotension rate in chronic hemodialysis patients. In order to evaluate these new devices in critically ill patients with acute kidney injury we decided to conduct a prospective randomized controlled trial.
We based calculation of the sample size on a power analysis that assumed an expected decrease in intra-dialytic hypotension rate of 40% (from a crude intra-dialytic hypotension rate of 30% to 18%) in groups B and C, compared with group A. Analysis is done by intention to treat, according to prescribed new dialysis on-line monitoring devices.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Gold standard bicarbonate hemodialysis therapy with constant ultrafiltration rate and dialysis conductivity performed with Fresenius 4008S monitor (Fresenius Medical Care, France)
Other names: Treatment A
Hemodialysis using Blood Volume on-line monitoring only. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® device (for blood volume monitor; Fresenius Medical Care, France)
Other names: Treatment B
Hemodialysis using Blood volume and Blood temperature on-line monitoring. Hemodialysis will be performed with Fresenius 4008S monitor (Fresenius Medical Care, France) equipped with BVM® and BTM® devices (for blood volume monitor and blood temperature management, respectively; Fresenius Medical Care, France)
Other names: Treatment C
Time frame: 60 days
Time frame: 60 days
University Hospital, Caen
Other
HEMOTOL: Effects of New Dialysis On-line Monitoring Devices on Hemodynamic Stability During Intermittent Hemodialysis in Critically Ill Patients With Acute Kidney Injury : a Prospective Randomized Study.
Acronym: HEMOTOL
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07637435
Acute Kidney Injury, Female Urogenital Diseases
Muğla, Menteşe, Turkey (Türkiye)
View Trial DetailsNCT03350308
Cardiovascular Diseases, Chronical Kidney Disease
Clermont-Ferrand, France
View Trial DetailsNCT01267617
Cardiovascular Diseases, Circulatory Stress
Pittsburgh, Pennsylvania, United States
View Trial DetailsNCT01098149
Cardiovascular Diseases, Hemodialysis
Imola, Bologna, Italy
View Trial Details