Up to 50 sites are proposed in Japan and the United States to enroll 286 subjects (271 evaluable) in each of 2 arms, for a total sample size of 572 subjects (542 evaluable) who are admitted to the hospital for a planned (elective and urgent) percutaneous coronary artery intervention procedure.
After stent implantation, subjects will be contacted for follow-up at 30 days; 6 months; and 1, 2, 3, 4, and 5 years. At 12 months a clinical evaluation will be completed before cardiac catheterization and angiographic assessment.
Rationale: This study is intended to demonstrate that the Combo stent platform shows superiority to an imputed Bare Metal Stent (BMS) performance goal, noninferior effectiveness and safety vs best-in-class second-generation everolimus-eluting stent (EES) (Xience V, Xience Prime, Xience Xpedition stents; [Abbott Vascular/Abbott Vascular Japan]), and evidence of mechanistic activity of the anti-CD34-Ab endothelial progenitor cell (EPC) capture technology with healthy level of intimal tissue coverage superior to that of the best-in-class EES.
To ensure the robustness and interpretability of results, the current proposal includes a number of unique design features:
- Largest randomized Drug-Eluting Stent (DES) study ever performed in Japan
- Enriched population, including stabilized Non-ST-elevation myocardial infarction (NSTEMI) subjects with greater likelihood of plaque rupture associated with their clinical syndromes
- Collaboration between with Japan and the United States as a "Proof of Concept" program under the auspices of the Harmonization by Doing Initiative, Working Group 1 (WG 1), including concomitant enrollment in U.S.A. sites as an FDA-approved Investigational Device Exemption (IDE) study
- Head-to-head randomization against state-of-the-art EES platform control, analyzed for clinical noninferiority
- Statistical analysis vs imputed BMS analyzed for clinical superiority
- Fractional flow reserve (FFR) follow-up of 100% of subjects enrolled, providing clinically relevant physiologic assessment of all subjects for 1 year ischemia-driven Target Vessel Revascularization (TVR) analysis
- Mechanistic Optical coherence tomography (OCT) imaging observations in 140 subjects using 6 French catheters as follows:
- Cohort A (30 subjects, 1:1 Combo and EES): Mechanistic imaging observations to provide serial 6 month and 1 year OCT evaluation of healthy intimal tissue coverage, intracoronary thrombosis, and stent malapposition and quantitative coronary angiographic (QCA) analysis to assess 1 year late loss.
- Cohort B (110 subjects, 1:1 Combo and EES): Mechanistic imaging observations to assess 1 year OCT evaluation of healthy intimal tissue coverage, intracoronary thrombosis, and stent malapposition, and QCA analysis to assess 1 year late loss. Combined with the 12 month imaging of Cohort A, this study will provide OCT and QCA observations at 1 year in 140 patients, half with Combo and half with EES.
- Cohort C: 432 subjects (216 subjects per arm) will undergo all clinical follow-up assessments with FFR and angiographic assessments at 12 months. Cohort C will be the last cohort to enroll.
- In the 110 subjects in Cohort B, 30 day and 1 year human antimurine antibody (HAMA) titers will also be collected.